메뉴 건너뛰기




Volumn 213, Issue 2, 1999, Pages 468-472

Renal cyst pseudoenhancement: Beam-hardening effects on CT numbers

Author keywords

Kidney, CT; Kidney, cysts

Indexed keywords

IONIC CONTRAST MEDIUM; MEGLUMINE IOTALAMATE;

EID: 0032737285     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.213.2.r99nv33468     Document Type: Article
Times cited : (175)

References (10)
  • 1
    • 0030094477 scopus 로고    scopus 로고
    • Problems in the detection and characterization of small renal masses
    • Bosniak MA, Rofsky NM. Problems in the detection and characterization of small renal masses. Radiology 1996; 1998:638-641.
    • (1996) Radiology , vol.1998 , pp. 638-641
    • Bosniak, M.A.1    Rofsky, N.M.2
  • 2
    • 0022630452 scopus 로고
    • The current radiologic approach to renal cysts
    • Bosniak MA. The current radiologic approach to renal cysts. Radiology 1986; 158:1-10.
    • (1986) Radiology , vol.158 , pp. 1-10
    • Bosniak, M.A.1
  • 3
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single breath-hold technique, continuous transport, and continuous scanner rotation
    • Kalendar WA, Sissler W, Klotz E, Vock P. Spiral volumetric CT with single breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 1990; 176:181-183.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalendar, W.A.1    Sissler, W.2    Klotz, E.3    Vock, P.4
  • 4
    • 0032910064 scopus 로고    scopus 로고
    • Assessment of a bolus tracking technique in helical renal CT to optimize nephrographic phase imaging
    • Birnbaum BA, JacobsJE, Langlotz CP, Ramchandani P. Assessment of a bolus tracking technique in helical renal CT to optimize nephrographic phase imaging. Radiology 1999; 211:87-94.
    • (1999) Radiology , vol.211 , pp. 87-94
    • Birnbaum, B.A.1    Jacobs, J.E.2    Langlotz, C.P.3    Ramchandani, P.4
  • 6
    • 0004171860 scopus 로고
    • Public Health Service Publication no. 2016. Washington, DC: Government Printing Office
    • U.S. Department of Health Education and Welfare, Public Health Service, Food and Drug Administration, Bureau of Radiological Health. Radiological Health Handbook. Public Health Service Publication no. 2016. Washington, DC: Government Printing Office, 1970; 137-139.
    • (1970) Radiological Health Handbook , pp. 137-139
  • 7
    • 0017195533 scopus 로고
    • Beam hardening in x-ray reconstruction tomography
    • Brooks RA, DiChiro G. Beam hardening in x-ray reconstruction tomography. Phys Med Biol 1976; 21:390-398.
    • (1976) Phys Med Biol , vol.21 , pp. 390-398
    • Brooks, R.A.1    DiChiro, G.2
  • 8
    • 0019362811 scopus 로고
    • The environmental density artifact: A beam-hardening effect in computed tomography
    • Rao PS, Alfidi RJ. The environmental density artifact: a beam-hardening effect in computed tomography. Radiology 1981; 141:223-227.
    • (1981) Radiology , vol.141 , pp. 223-227
    • Rao, P.S.1    Alfidi, R.J.2
  • 9
    • 0023771636 scopus 로고
    • Correction for scattered radiation and other background signals in dual-energy computed tomography material thickness measurements
    • Vetter JR, Holden JE. Correction for scattered radiation and other background signals in dual-energy computed tomography material thickness measurements. Med Phys 1988; 15:726-731.
    • (1988) Med Phys , vol.15 , pp. 726-731
    • Vetter, J.R.1    Holden, J.E.2
  • 10
    • 0030867231 scopus 로고    scopus 로고
    • A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine
    • Joseph PM, Ruth C. A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine. Med Phys 1997; 24: 1629-1634.
    • (1997) Med Phys , vol.24 , pp. 1629-1634
    • Joseph, P.M.1    Ruth, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.