메뉴 건너뛰기




Volumn 6, Issue 4, 1999, Pages 235-237

Evaluation of tibial component angles in 79 consecutive total knee arthroplasties

Author keywords

Component alignment; Tibial component angle; Total knee replacement

Indexed keywords

ANATOMY; ARTICLE; HUMAN; KNEE RADIOGRAPHY; MAJOR CLINICAL STUDY; MEASUREMENT; PRIORITY JOURNAL; TIBIA; TOTAL KNEE REPLACEMENT; VARUS KNEE;

EID: 0032730162     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0968-0160(99)00015-0     Document Type: Article
Times cited : (20)

References (22)
  • 2
    • 0022623497 scopus 로고
    • Correction of alignment deformities during total knee arthroplasties
    • Clayton M.L., Thompson R.T., Mack R.P. Correction of alignment deformities during total knee arthroplasties. Clin Orthop. 202:1986;117-124.
    • (1986) Clin Orthop , vol.202 , pp. 117-124
    • Clayton, M.L.1    Thompson, R.T.2    Mack, R.P.3
  • 3
    • 0026319814 scopus 로고
    • Effect of the tibial cut on subsidence following total knee arthroplasty
    • Hoffinan A.A., Bachus K.N., Wyatt R.W.B. Effect of the tibial cut on subsidence following total knee arthroplasty. Clin Orthop. 269:1991;63-69.
    • (1991) Clin Orthop , vol.269 , pp. 63-69
    • Hoffinan, A.A.1    Bachus, K.N.2    Wyatt, R.W.B.3
  • 4
    • 0019470406 scopus 로고
    • The correction of knee alignment in 225 consecutive total condylar knee replacements
    • Hood R.W., Vanni M., Insall J.N. The correction of knee alignment in 225 consecutive total condylar knee replacements. Clin Orthop. 160:1981;94-105.
    • (1981) Clin Orthop , vol.160 , pp. 94-105
    • Hood, R.W.1    Vanni, M.2    Insall, J.N.3
  • 5
    • 0020617864 scopus 로고
    • Preliminary experience with a total knee prosthesis with porous coating used without cement
    • Hungerford D.S., Kenna R.V. Preliminary experience with a total knee prosthesis with porous coating used without cement. Clin Orthop. 176:1983;95-107.
    • (1983) Clin Orthop , vol.176 , pp. 95-107
    • Hungerford, D.S.1    Kenna, R.V.2
  • 6
    • 0021360668 scopus 로고
    • Total condylar knee arthroplasty
    • Hvid I., Nielsen S. Total condylar knee arthroplasty. Acta Orthop Scand. 55:1984;160-165.
    • (1984) Acta Orthop Scand , vol.55 , pp. 160-165
    • Hvid, I.1    Nielsen, S.2
  • 8
    • 0023841818 scopus 로고
    • Alignment and long-term clinical results of a semi-constrained knee prosthesis
    • Jonsson B., Astrom J. Alignment and long-term clinical results of a semi-constrained knee prosthesis. Clin Orthop. 226:1988;124-128.
    • (1988) Clin Orthop , vol.226 , pp. 124-128
    • Jonsson, B.1    Astrom, J.2
  • 9
    • 0017353885 scopus 로고
    • Influence of positioning of prosthesis in total knee replacement
    • Lotke P.A., Ecker M.L. Influence of positioning of prosthesis in total knee replacement. J Bone Jt Surg [Am]. 59-A:1977;77-79.
    • (1977) J Bone Jt Surg [Am] , vol.59 , pp. 77-79
    • Lotke, P.A.1    Ecker, M.L.2
  • 10
    • 0022353339 scopus 로고
    • Tibiofemoral alignment and the results of knee replacement
    • Tew M., Waugh W. Tibiofemoral alignment and the results of knee replacement. J Bone Jt Surg (Br). 67-B:1985;551-556.
    • (1985) J Bone Jt Surg (Br) , vol.67 , pp. 551-556
    • Tew, M.1    Waugh, W.2
  • 12
    • 0002421676 scopus 로고
    • Total knee replacement
    • J.N. Insall. New York: Churchill Livingstone
    • Insall J.N. Total knee replacement. Insall J.N. Surgery of the knee. 1984;Churchill Livingstone, New York.
    • (1984) Surgery of the Knee
    • Insall, J.N.1
  • 13
    • 0028322219 scopus 로고
    • Corrective osteotomies for lower limb deformities
    • Paley D. Corrective osteotomies for lower limb deformities. Curr Orthop. 8:1994;182-195.
    • (1994) Curr Orthop , vol.8 , pp. 182-195
    • Paley, D.1
  • 14
    • 85047689552 scopus 로고
    • Radiological study of the accuracy of a tibial intramedullary cutting guide for knee arthroplasty
    • Evans P.D., Marshall P.D., McDonnell B., Richards J., Evans E.J. Radiological study of the accuracy of a tibial intramedullary cutting guide for knee arthroplasty. J Arthroplasty. 10:1995;43-46.
    • (1995) J Arthroplasty , vol.10 , pp. 43-46
    • Evans, P.D.1    Marshall, P.D.2    McDonnell, B.3    Richards, J.4    Evans, E.J.5
  • 15
    • 0027231237 scopus 로고
    • Intramedullary versus extramedullary tibial alignment systems in total knee arthroplasty
    • Dennis D.A., Channer M., Susman M.H., Stringer E.A. Intramedullary versus extramedullary tibial alignment systems in total knee arthroplasty. J Arthroplasty. 8:1993;43-47.
    • (1993) J Arthroplasty , vol.8 , pp. 43-47
    • Dennis, D.A.1    Channer, M.2    Susman, M.H.3    Stringer, E.A.4
  • 16
    • 0029123439 scopus 로고
    • Extramedullary versus intramedullary alignment guides in total knee arthroplasty
    • Iishii Y., Ohmori G., Bechtold J.E., Gustilo R.B. Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop. 318:1995;167-175.
    • (1995) Clin Orthop , vol.318 , pp. 167-175
    • Iishii, Y.1    Ohmori, G.2    Bechtold, J.E.3    Gustilo, R.B.4
  • 17
    • 0026063006 scopus 로고
    • Radiological study of alignment after total knee replacement
    • Patel D.V., Ferris B.D., Aichroth P.M. Radiological study of alignment after total knee replacement. Int Orthop. 15:1991;209-210.
    • (1991) Int Orthop , vol.15 , pp. 209-210
    • Patel, D.V.1    Ferris, B.D.2    Aichroth, P.M.3
  • 18
    • 0027170064 scopus 로고
    • Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty
    • Oswald M.H., Jakob R.P., Schneider E., Hoogewoud H.-M. Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty. 8:1993;419-426.
    • (1993) J Arthroplasty , vol.8 , pp. 419-426
    • Oswald, M.H.1    Jakob, R.P.2    Schneider, E.3    Hoogewoud, H.-M.4
  • 19
    • 0026662250 scopus 로고
    • Accuracy of intramedullary alignment in total knee replacement
    • Elloy M.A., Manning M.P., Johnson R. Accuracy of intramedullary alignment in total knee replacement. J Biomed Eng. 14:1992;363-370.
    • (1992) J Biomed Eng , vol.14 , pp. 363-370
    • Elloy, M.A.1    Manning, M.P.2    Johnson, R.3
  • 20
    • 0025859647 scopus 로고
    • Measurement of lower limb alignment using long radiographs
    • Wright J.G., Treble N., Feinstein A.R. Measurement of lower limb alignment using long radiographs. J Bone Jt Surg [Br]. 73-B:1991;721-723.
    • (1991) J Bone Jt Surg [Br] , vol.73 , pp. 721-723
    • Wright, J.G.1    Treble, N.2    Feinstein, A.R.3
  • 21
    • 0003003202 scopus 로고
    • Technical factors that influence mechanical loosening of total knee arthroplasty
    • L.D. Dorr. Baltimore: University Park Press
    • Dorr L.D., Conaty J.P., Schreffier R., Mehne D.K., Hull D. Technical factors that influence mechanical loosening of total knee arthroplasty. Dorr L.D. The knee. 1985;121-135 University Park Press, Baltimore.
    • (1985) The Knee , pp. 121-135
    • Dorr, L.D.1    Conaty, J.P.2    Schreffier, R.3    Mehne, D.K.4    Hull, D.5
  • 22
    • 0023893141 scopus 로고
    • Radiographic assessment of knee alignment after total knee arthroplasty
    • Petersen T.L., Engh G.A. Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty. 3:1988;67-72.
    • (1988) J Arthroplasty , vol.3 , pp. 67-72
    • Petersen, T.L.1    Engh, G.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.