메뉴 건너뛰기




Volumn 42, Issue 3, 1999, Pages 231-234

Utilization of a model lung system to assess the effects of an inspiratory impedance threshold valve on the relationship between active decompression and intra-thoracic pressure

Author keywords

Active compression decompression; Impedance; Lung

Indexed keywords

ARTICLE; COMPRESSION; DECOMPRESSION; DEVICE; IMPEDANCE; LUNG FUNCTION; MODEL; PRIORITY JOURNAL; RESUSCITATION; THORAX PRESSURE;

EID: 0032728892     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0300-9572(99)00113-6     Document Type: Article
Times cited : (6)

References (6)
  • 1
    • 0026593718 scopus 로고
    • Active compression-decompression: A new method of cardiopulmonary resuscitation: Cardiopulmonary Resuscitation Working Group
    • Cohen T.J., Tucker K.J., Lurie K.G., Redberg R.F., Dutton J.P., Dwyer K.A. et al. Active compression-decompression: a new method of cardiopulmonary resuscitation: Cardiopulmonary Resuscitation Working Group. JAMA. 267:1992;2916-2923.
    • (1992) JAMA , vol.267 , pp. 2916-2923
    • Cohen, T.J.1    Tucker, K.J.2    Lurie, K.G.3    Redberg, R.F.4    Dutton, J.P.5    Dwyer, K.A.6
  • 3
    • 0028959943 scopus 로고
    • Improving active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve
    • Lurie K.G., Coffeen P., Schultz J., McKnite S., Detloff B., Mulligan K. Improving active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve. Circulation. 91:1995;1629-1632.
    • (1995) Circulation , vol.91 , pp. 1629-1632
    • Lurie, K.G.1    Coffeen, P.2    Schultz, J.3    McKnite, S.4    Detloff, B.5    Mulligan, K.6
  • 4
    • 0031977042 scopus 로고    scopus 로고
    • Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve
    • Lurie K.G., Mulligan K.A., McKnite S., Detloff B., Lindstrom P., Lindner K.H. Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve. Chest. 113:1998;1084-1090.
    • (1998) Chest , vol.113 , pp. 1084-1090
    • Lurie, K.G.1    Mulligan, K.A.2    McKnite, S.3    Detloff, B.4    Lindstrom, P.5    Lindner, K.H.6
  • 6
    • 0345064640 scopus 로고
    • An evaluation, in four ventilators, of characteristics that affect work of breathing
    • Capps J.S., Ritz R., Pierson D.J. An evaluation, in four ventilators, of characteristics that affect work of breathing. Respir. Care. 32:1987;1017-1024.
    • (1987) Respir. Care. , vol.32 , pp. 1017-1024
    • Capps, J.S.1    Ritz, R.2    Pierson, D.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.