메뉴 건너뛰기




Volumn 15, Issue 5, 1999, Pages 295-298

Evaluation of a new fibre-optical monitor for respiratory rate monitoring

Author keywords

Fibre optical; Monitoring; Respiratory rate

Indexed keywords

FIBER OPTIC SENSORS; RESPIRATORY MECHANICS;

EID: 0032726589     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1009967122272     Document Type: Article
Times cited : (10)

References (13)
  • 1
    • 0024582583 scopus 로고
    • Prevention of intraoperative anesthesia accidents and related severe injury through safety monitoring
    • Eichhorn JH. Prevention of intraoperative anesthesia accidents and related severe injury through safety monitoring. Anesthesiology 1989; 70: 572-577
    • (1989) Anesthesiology , vol.70 , pp. 572-577
    • Eichhorn, J.H.1
  • 2
    • 0029005959 scopus 로고
    • Late post-operative hypoxemia and organ dysfunction
    • Kehlet H, Rosenberg J. Late post-operative hypoxemia and organ dysfunction. Eur J Anaesth 1995; 12 (10): 31-34
    • (1995) Eur J Anaesth , vol.12 , Issue.10 , pp. 31-34
    • Kehlet, H.1    Rosenberg, J.2
  • 4
    • 0024445550 scopus 로고
    • Role of monitoring devices in prevention of anesthetic mishap: A closed claims analysis
    • Tinker JH, Dull DL, Caplan RA, Ward RJ, Cheny FW. Role of monitoring devices in prevention of anesthetic mishap: A closed claims analysis. Anesthesiology 1989; 71: 541-546
    • (1989) Anesthesiology , vol.71 , pp. 541-546
    • Tinker, J.H.1    Dull, D.L.2    Caplan, R.A.3    Ward, R.J.4    Cheny, F.W.5
  • 5
    • 0026039401 scopus 로고
    • Association of postoperative apnea, airway obstruction, and hypoxemia in former premature infants
    • Kurth CD, LeBard SE. Association of postoperative apnea, airway obstruction, and hypoxemia in former premature infants. Anesthesiology 1991; 75: 22-26
    • (1991) Anesthesiology , vol.75 , pp. 22-26
    • Kurth, C.D.1    LeBard, S.E.2
  • 6
    • 0027293153 scopus 로고
    • Limitations of pulse oximetry: Respiratory insufficiency - A failure of detection
    • Davidson JAH, Hosie HE. Limitations of pulse oximetry: respiratory insufficiency - a failure of detection. BMJ 1993; 307: 372-373
    • (1993) BMJ , vol.307 , pp. 372-373
    • Davidson, J.A.H.1    Hosie, H.E.2
  • 7
    • 0027326160 scopus 로고
    • A new respiratory rate monitor: Development and initial clinical experience
    • Hök B, Wiklund L, Henneberg S. A new respiratory rate monitor: development and initial clinical experience. J Clin Monit Comput 1993; 10: 101-107
    • (1993) J Clin Monit Comput , vol.10 , pp. 101-107
    • Hök, B.1    Wiklund, L.2    Henneberg, S.3
  • 8
    • 0027303863 scopus 로고
    • Experimental evaluation of two new sensors for respiratory rate monitoring
    • Vegfors M, Ugnell H, Hök B, Lennmarken C. Experimental evaluation of two new sensors for respiratory rate monitoring. Physiol Meas 1993; 14: 171-181
    • (1993) Physiol Meas , vol.14 , pp. 171-181
    • Vegfors, M.1    Ugnell, H.2    Hök, B.3    Lennmarken, C.4
  • 9
    • 0027214620 scopus 로고
    • The benefits and pitfalls of pulse oximetry
    • Hutton P, Glutton-Brock T. The benefits and pitfalls of pulse oximetry. BMJ 1993; 307: 457
    • (1993) BMJ , vol.307 , pp. 457
    • Hutton, P.1    Glutton-Brock, T.2
  • 10
    • 0028946159 scopus 로고
    • Pulse oximetry - Clinical implications and recent technical developments
    • Lindberg LG, Lennmarken C, Vegfors M. Pulse oximetry - clinical implications and recent technical developments. Acta Anaesthesiol. Scand. 1995; 39: 279-287
    • (1995) Acta Anaesthesiol. Scand. , vol.39 , pp. 279-287
    • Lindberg, L.G.1    Lennmarken, C.2    Vegfors, M.3
  • 11
    • 0027935849 scopus 로고
    • Presentation and evaluation of a new optical sensor for respiratory rate monitoring
    • Vegfors M, Lindberg LG, Pettersson H, Öberg PÅ. Presentation and evaluation of a new optical sensor for respiratory rate monitoring. Int J Clin Monit Comput 1994; 11: 151-156
    • (1994) Int J Clin Monit Comput , vol.11 , pp. 151-156
    • Vegfors, M.1    Lindberg, L.G.2    Pettersson, H.3    Öberg, P.Å.4
  • 12
    • 0026621220 scopus 로고
    • Circardian variation in unexpected postoperative death
    • Rosenberg J, Pedersen MH, Ramsing T, Kehlet H. Circardian variation in unexpected postoperative death. Br J Surg 1992; 79: 1300-1302
    • (1992) Br J Surg , vol.79 , pp. 1300-1302
    • Rosenberg, J.1    Pedersen, M.H.2    Ramsing, T.3    Kehlet, H.4
  • 13
    • 0032618863 scopus 로고    scopus 로고
    • Respiratory monitoring during MR imaging. the clinical value of a new fibre-optical monitor
    • Larsson C, Davidsson L, Gustafsson G, Vegfors M. Respiratory monitoring during MR imaging. The clinical value of a new fibre-optical monitor. Acta Radiologica 1999; 40: 33-36
    • (1999) Acta Radiologica , vol.40 , pp. 33-36
    • Larsson, C.1    Davidsson, L.2    Gustafsson, G.3    Vegfors, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.