Volumn 121, Issue 4, 1999, Pages 393-398

Calibration and application of an intra-articular force transducer for the measurement of patellar tendon graft forces: An in situ evaluation

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; FORCE MEASUREMENT; GRAFTS; IMPLANTS (SURGICAL); JOINTS (ANATOMY); LIGAMENTS; LOAD TESTING; TENDONS; TRANSDUCERS;

EID: 0032722082     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.2798336     Document Type: Article
Times cited : (14)

References (19)
  • 2
    • 0025456776 scopus 로고
    • Anterior Cruciate Ligament Replacements: A Mechanical Study of Femoral Attachment Location, Flexion Angle at Tensioning, and Initial Tension
    • Bylski-Austrow, D. I., Grood, E. S., Hefzy, M. S., Holden, J. P., and Butler, D. L., 1990, “Anterior Cruciate Ligament Replacements: A Mechanical Study of Femoral Attachment Location, Flexion Angle at Tensioning, and Initial Tension,” J. Orthop. Res., Vol. 8, pp. 522-531.
    • (1990) J. Orthop. Res , vol.8 , pp. 522-531
    • Bylski-Austrow, D.I.1    Grood, E.S.2    Hefzy, M.S.3    Holden, J.P.4    Butler, D.L.5
  • 3
    • 0026832884 scopus 로고
    • The Effect of Tension and Placement of a Prosthetic Anterior Cruciate Ligament on the Anteroposterior Laxity of the Knee
    • Fleming, B. C., Beynnon, B. D., Howe, J. G., McLeod, W. D., and Pope, M. H., 1992, “The Effect of Tension and Placement of a Prosthetic Anterior Cruciate Ligament on the Anteroposterior Laxity of the Knee,” J. Orthop. Res., Vol. 10, pp. 177-186.
    • (1992) J. Orthop. Res , vol.10 , pp. 177-186
    • Fleming, B.C.1    Beynnon, B.D.2    Howe, J.G.3    McLeod, W.D.4    Pope, M.H.5
  • 4
    • 0028533679 scopus 로고
    • The Determination of a Zero Strain Reference for the Anteromedial Band of the Anterior Cruciate Ligament
    • Fleming, B. C., Beynnon, B. D., Tohyama, H., Johnson, R. J., Nichols, C. E., Renstrom, P., and Pope, M. H., 1994, “The Determination of a Zero Strain Reference for the Anteromedial Band of the Anterior Cruciate Ligament,” J. Orthop. Res., Vol. 12, pp. 789-795.
    • (1994) J. Orthop. Res , vol.12 , pp. 789-795
    • Fleming, B.C.1    Beynnon, B.D.2    Tohyama, H.3    Johnson, R.J.4    Nichols, C.E.5    Renstrom, P.6    Pope, M.H.7
  • 5
    • 0027703506 scopus 로고
    • In Vitro Evaluation of an Implantable Force Transducer (IFT) in a Patellar Tendon Model
    • Glos, D. L., Butler, D. L., Grood, E. S., and Levy, M. S., 1993, “In Vitro Evaluation of an Implantable Force Transducer (IFT) in a Patellar Tendon Model,” ASME Journal of Biomechanical Engineering, Vol. 115, pp. 335-343.
    • (1993) ASME Journal of Biomechanical Engineering , vol.115 , pp. 335-343
    • Glos, D.L.1    Butler, D.L.2    Grood, E.S.3    Levy, M.S.4
  • 6
    • 0029311125 scopus 로고
    • In Vitro Correlation Between Tension and Length Change in an Anterior Cruciate Ligament Substitute
    • Good, L., and Gillquist, J., 1995, “In Vitro Correlation Between Tension and Length Change in an Anterior Cruciate Ligament Substitute,” Clin. Biomech., Vol. 10, pp. 200-207.
    • (1995) Clin. Biomech , vol.10 , pp. 200-207
    • Good, L.1    Gillquist, J.2
  • 7
    • 0030032281 scopus 로고    scopus 로고
    • Evaluation of the Implantable Force Transducer for Chronic Tendon-Force Recordings
    • Herzog, W., Archambault, J. M., Leonard, T. R., and Nguyen, H. K., 1996a, “Evaluation of the Implantable Force Transducer for Chronic Tendon-Force Recordings,” J. Biomech., Vol. 29, pp. 103-109.
    • (1996) J. Biomech , vol.29 , pp. 103-109
    • Herzog, W.1    Archambault, J.M.2    Leonard, T.R.3    Nguyen, H.K.4
  • 8
    • 0030560666 scopus 로고    scopus 로고
    • In-Situ Calibration of the Implantable Force Transducer
    • Herzog, W., Hasler, E. M., and Leonard, T. R., 1996b, “In-Situ Calibration of the Implantable Force Transducer,” J. Biomech., Vol. 29, pp. 1649-1652.
    • (1996) J. Biomech , vol.29 , pp. 1649-1652
    • Herzog, W.1    Hasler, E.M.2    Leonard, T.R.3
  • 9
    • 0028434083 scopus 로고
    • In Vivo Forces in the Anterior Cruciate Ligament: Direct Measurements During Walking and Trotting in a Quadruped
    • Holden, J. P., Grood, E. S., Korvick, D. L., Cummings, J. F., Butler, D. L., and Bylski-Austrow, D. I., 1994, “In Vivo Forces in the Anterior Cruciate Ligament: Direct Measurements During Walking and Trotting in a Quadruped,” J. Biomech., Vol. 27, pp. 517-526.
    • (1994) J. Biomech , vol.27 , pp. 517-526
    • Holden, J.P.1    Grood, E.S.2    Korvick, D.L.3    Cummings, J.F.4    Butler, D.L.5    Bylski-Austrow, D.I.6
  • 10
    • 0028958365 scopus 로고
    • Factors Affecting Sensitivity of a Transducer for Measuring Anterior Cruciate Ligament Force
    • Holden, J. P., Grood, E. S., and Cummings, J. F., 1995, “Factors Affecting Sensitivity of a Transducer for Measuring Anterior Cruciate Ligament Force,” J. Biomech., Vol. 28, pp. 99-102.
    • (1995) J. Biomech , vol.28 , pp. 99-102
    • Holden, J.P.1    Grood, E.S.2    Cummings, J.F.3
  • 11
    • 0020134577 scopus 로고
    • A Note on the Application and Evaluation of the Buckle Transducer for Knee Ligament Force Measurement
    • Lewis, J. L., Lew, W. D., and Schmidt, J., 1982, “A Note on the Application and Evaluation of the Buckle Transducer for Knee Ligament Force Measurement,” ASME Journal of Biomechanical Engineering, Vol. 104, pp. 125-128.
    • (1982) ASME Journal of Biomechanical Engineering , vol.104 , pp. 125-128
    • Lewis, J.L.1    Lew, W.D.2    Schmidt, J.3
  • 12
    • 0023914162 scopus 로고
    • An in vivo study of anterior cruciate ligament graft replacement and isometry
    • Penner, D. A., Daniel, D. M., Wood, P., and Mishra, D., 1988, “An in vivo study of anterior cruciate ligament graft replacement and isometry,” Am. J. Sports Med., Vol. 16, pp. 238-243.
    • (1988) Am. J. Sports Med , vol.16 , pp. 238-243
    • Penner, D.A.1    Daniel, D.M.2    Wood, P.3    Mishra, D.4
  • 14
    • 0028630508 scopus 로고
    • Novel Force Transducer for the Measurement of Tendon Force In Vivo
    • Platt, D., Wilson, A. M., Timbs, A., Wright, I. M., and Goodship, A. E.,1994, “Novel Force Transducer for the Measurement of Tendon Force In Vivo,” J. Biomech., Vol. 27, pp. 1489-1493.
    • (1994) J. Biomech , vol.27 , pp. 1489-1493
    • Platt, D.1    Wilson, A.M.2    Timbs, A.3    Wright, I.M.4    Goodship, A.E.5
  • 15
    • 0002203233 scopus 로고
    • In Vivo Measurement of Human Anterior Cruciate Ligament Forces During Knee Extension Exercises
    • Roberts, C. S., Cummings, J. F., Grood, E. S., and Noyes, F. R., 1994, “In Vivo Measurement of Human Anterior Cruciate Ligament Forces During Knee Extension Exercises,” Trans. Orthop. Res. Soc., Vol. 19, p. 84.
    • (1994) Trans. Orthop. Res. Soc , vol.19 , pp. 84
    • Roberts, C.S.1    Cummings, J.F.2    Grood, E.S.3    Noyes, F.R.4
  • 17
    • 0343413299 scopus 로고
    • Evaluation of the Arthroscopic Force Probe: A Study of the Factors That Affect the Measurement of Tendon and Ligament Forces In Vivo
    • Tohyama, H., Beynnon, B. D., Fleming, B. C., Peura, G. D., Johnson, R. J., and Pope, M. H., 1994, “Evaluation of the Arthroscopic Force Probe: A Study of the Factors That Affect the Measurement of Tendon and Ligament Forces In Vivo,” Trans. Orthop. Res. Soc., Vol. 19, p. 644.
    • (1994) Trans. Orthop. Res. Soc , vol.19 , pp. 644
    • Tohyama, H.1    Beynnon, B.D.2    Fleming, B.C.3    Peura, G.D.4    Johnson, R.J.5    Pope, M.H.6
  • 18
    • 0344658319 scopus 로고    scopus 로고
    • In Vivo Tension Measurements in a Double-Looped Hamstrings Graft for Anterior Cruciate Ligament Replacement
    • Wallace, M. P., Howell, S. M., and Hull, M. L., 1996, “In Vivo Tension Measurements in a Double-Looped Hamstrings Graft for Anterior Cruciate Ligament Replacement,” Trans. Orthop. Res. Soc., Vol. 21, p. 74.
    • (1996) Trans. Orthop. Res. Soc , vol.21 , pp. 74
    • Wallace, M.P.1    Howell, S.M.2    Hull, M.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.