메뉴 건너뛰기




Volumn 13, Issue 6, 1999, Pages 576-581

Impact of red cell salvage on transfusion requirements during elective abdominal aortic aneurysm repair

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; BLOOD AUTOTRANSFUSION; CONFERENCE PAPER; COST EFFECTIVENESS ANALYSIS; DRUG BIOAVAILABILITY; DRUG SAFETY; ERYTHROCYTE TRANSFUSION; FEMALE; HEMODILUTION; HEMOGLOBIN DETERMINATION; HUMAN; HUMAN CELL; HUMAN TISSUE; MAJOR CLINICAL STUDY; MALE; PREVALENCE; PRIORITY JOURNAL;

EID: 0032717211     PISSN: 08905096     EISSN: None     Source Type: Journal    
DOI: 10.1007/s100169900301     Document Type: Conference Paper
Times cited : (11)

References (20)
  • 1
    • 0028352298 scopus 로고
    • Alternatives to homologous blood transfusion
    • Tawes RL. Alternatives to homologous blood transfusion. Semin Vase Surg 1994;72:72-75.
    • (1994) Semin Vase Surg , vol.72 , pp. 72-75
    • Tawes, R.L.1
  • 2
    • 85133612969 scopus 로고    scopus 로고
    • Guidelines for red blood cell and plasma transfusion for adults and children
    • Guidelines for Red Blood Cell and Plasma Transfusion for Adults and Children. Can Med Assoc J (Suppl) 1997; 156(11).
    • (1997) Can Med Assoc J (Suppl) , vol.156 , Issue.11
  • 3
    • 0028923975 scopus 로고
    • The cost-effectiveness of preoperative autologous blood donations
    • Etchason J, Petz L, Keeler E, et al. The cost-effectiveness of preoperative autologous blood donations. N Engl J Med 1995;332:719-724.
    • (1995) N Engl J Med , vol.332 , pp. 719-724
    • Etchason, J.1    Petz, L.2    Keeler, E.3
  • 5
    • 0001723398 scopus 로고
    • Blood replacement and autotransfusion in major vascular surgery
    • Rutherford RB, ed. Philadelphia: W.B. Saunders
    • Tawes RL. Blood replacement and autotransfusion in major vascular surgery. In Rutherford RB, ed. Vascular Surgery. Philadelphia: W.B. Saunders, 1995, pp 433-446.
    • (1995) Vascular Surgery , pp. 433-446
    • Tawes, R.L.1
  • 7
    • 0028051499 scopus 로고
    • Preoperatively assessing and planning blood use for elective vascular surgery
    • Spence RK, Atabek U, Alexander JB, et al. Preoperatively assessing and planning blood use for elective vascular surgery. Am J Surg 1994;168:192-196.
    • (1994) Am J Surg , vol.168 , pp. 192-196
    • Spence, R.K.1    Atabek, U.2    Alexander, J.B.3
  • 8
    • 0028355996 scopus 로고
    • Transfusion decision-making in vascular surgery: Blood ordering schedules and the transfusion trigger
    • Spence RK, Carson JA. Transfusion decision-making in vascular surgery: blood ordering schedules and the transfusion trigger. Semin Vasc Surg 1994;7:76-81.
    • (1994) Semin Vasc Surg , vol.7 , pp. 76-81
    • Spence, R.K.1    Carson, J.A.2
  • 9
    • 0030758431 scopus 로고    scopus 로고
    • A prospective randomized trial limiting perioperative blood cell transfusions in vascular patients
    • Bush RL, Pevec WC, Holcroft JW. A prospective randomized trial limiting perioperative blood cell transfusions in vascular patients. Am J Surg 1997;174:143-148.
    • (1997) Am J Surg , vol.174 , pp. 143-148
    • Bush, R.L.1    Pevec, W.C.2    Holcroft, J.W.3
  • 10
    • 0029831092 scopus 로고    scopus 로고
    • Autologous blood transfusion: Preoperative blood collection and blood salvage techniques
    • Bengtsson A, Bengtson JP. Autologous blood transfusion: preoperative blood collection and blood salvage techniques. Acta Anaesthesiol Scand 1996;40:1041-1056.
    • (1996) Acta Anaesthesiol Scand , vol.40 , pp. 1041-1056
    • Bengtsson, A.1    Bengtson, J.P.2
  • 11
    • 0028053254 scopus 로고
    • Reduction in the homologous blood requirement for abdominal aortic aneurysm repair by the use of preadmission autologous blood donation
    • O'Hara PJ, Hertzer NR, Krajewski LP, Cox GS, Beven EG. Reduction in the homologous blood requirement for abdominal aortic aneurysm repair by the use of preadmission autologous blood donation. Surgery 1994;115:69-76.
    • (1994) Surgery , vol.115 , pp. 69-76
    • O'Hara, P.J.1    Hertzer, N.R.2    Krajewski, L.P.3    Cox, G.S.4    Beven, E.G.5
  • 12
    • 0031081105 scopus 로고
    • Intraoperative hemodilution is more cost-effective than preoperative autologous donation for patients undergoing procedures associated with a low risk for transfusion
    • Rosenblatt MA, Cantos EM, Mohandas K. Intraoperative hemodilution is more cost-effective than preoperative autologous donation for patients undergoing procedures associated with a low risk for transfusion. J Clin Anesth 1994;9:26-29.
    • (1994) J Clin Anesth , vol.9 , pp. 26-29
    • Rosenblatt, M.A.1    Cantos, E.M.2    Mohandas, K.3
  • 13
    • 0030958474 scopus 로고    scopus 로고
    • The effect of acute normovolemic hemodilution on homologous blood requirements and total estimated red blood cell volume lost
    • Kahraman S, Altunkaya H, Celebioglu B, Kanbak M, Pasaoglu I, Erdem K. The effect of acute normovolemic hemodilution on homologous blood requirements and total estimated red blood cell volume lost. Acta Anaesthesiol Scand 1997;41:614-617.
    • (1997) Acta Anaesthesiol Scand , vol.41 , pp. 614-617
    • Kahraman, S.1    Altunkaya, H.2    Celebioglu, B.3    Kanbak, M.4    Pasaoglu, I.5    Erdem, K.6
  • 14
    • 0030919593 scopus 로고    scopus 로고
    • Guidelines for autologous transfusion II. Perioperative haemodilution and cell salvage
    • British Committee for Standards in Haematology Blood Transfusion Task Force. Guidelines for autologous transfusion II. Perioperative haemodilution and cell salvage. Br J Anaesth 1997;78:768-771.
    • (1997) Br J Anaesth , vol.78 , pp. 768-771
  • 15
    • 0028279514 scopus 로고
    • Autotransfusion in vascular surgery: An overview
    • Tawes RL. Autotransfusion in vascular surgery: an overview. Semin Vasc Surg 1994;7:67-71.
    • (1994) Semin Vasc Surg , vol.7 , pp. 67-71
    • Tawes, R.L.1
  • 16
    • 0028352299 scopus 로고
    • The physiological and technological basis for autotransfusion
    • Tawes RL. The physiological and technological basis for autotransfusion. Semin Vasc Surg 1994;7:91-92.
    • (1994) Semin Vasc Surg , vol.7 , pp. 91-92
    • Tawes, R.L.1
  • 17
    • 0028355997 scopus 로고
    • Postoperative salvage: A technological advance in the "washed" versus "unwashed" blood controversy
    • Tawes RL, Sydorak GR, DuVall TB. Postoperative salvage: a technological advance in the "washed" versus "unwashed" blood controversy. Semin Vasc Surg 1994;7:98-103.
    • (1994) Semin Vasc Surg , vol.7 , pp. 98-103
    • Tawes, R.L.1    Sydorak, G.R.2    DuVall, T.B.3
  • 18
    • 0028232166 scopus 로고
    • The basic concepts of an autotransfuser: The Cell-saver
    • Tawes RL, DuVall TB. The basic concepts of an autotransfuser: the Cell-Saver. Semin Vase Surg 1994;7:93-94.
    • (1994) Semin Vase Surg , vol.7 , pp. 93-94
    • Tawes, R.L.1    DuVall, T.B.2
  • 19
    • 0027198260 scopus 로고
    • Cell washing versus immediate reinfusion of intraoperatively shed blood during abdominal aortic aneurysm repair
    • Long GW, Glover JL, Bendick PJ. et al. Cell washing versus immediate reinfusion of intraoperatively shed blood during abdominal aortic aneurysm repair. Am J Surg 1993;166:97-102.
    • (1993) Am J Surg , vol.166 , pp. 97-102
    • Long, G.W.1    Glover, J.L.2    Bendick, P.J.3
  • 20
    • 0029819452 scopus 로고    scopus 로고
    • Intraoperative salvage in patients undergoing elective abdominal aortic aneurysm repair: An analysis of cost and benefit
    • Goodnough LT, Monk T, Sicard G, et al. Intraoperative salvage in patients undergoing elective abdominal aortic aneurysm repair: an analysis of cost and benefit. J Vasc Surg 1996;24:213-218.
    • (1996) J Vasc Surg , vol.24 , pp. 213-218
    • Goodnough, L.T.1    Monk, T.2    Sicard, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.