메뉴 건너뛰기




Volumn 72, Issue NOV., 1999, Pages 1073-1077

Radiation doses from CT in the Sultanate of Oman

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL PROTOCOL; COMPUTER ASSISTED TOMOGRAPHY; DOSE RESPONSE; DOSIMETRY; HUMAN; OMAN; RADIATION; RADIATION PROTECTION;

EID: 0032713987     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr.72.863.10700824     Document Type: Article
Times cited : (17)

References (16)
  • 2
    • 0029948078 scopus 로고    scopus 로고
    • Patient doses from CT in New Zealand and a simple method for estimating effective dose
    • Poletti JL. Patient doses from CT in New Zealand and a simple method for estimating effective dose. Br J Radiol 1996;69:432-6.
    • (1996) Br J Radiol , vol.69 , pp. 432-436
    • Poletti, J.L.1
  • 3
    • 0028800782 scopus 로고
    • The increasing importance of X-ray computed tomography as a source of medical exposure
    • Shrimpton PC, Wall BF. The increasing importance of X-ray computed tomography as a source of medical exposure. Radiat Prot Dosim 1995;57:413-5.
    • (1995) Radiat Prot Dosim , vol.57 , pp. 413-415
    • Shrimpton, P.C.1    Wall, B.F.2
  • 4
    • 0007143767 scopus 로고    scopus 로고
    • EC Working Document EUR 16262. Brussels: EC
    • European Commission Study Group. Quality criteria for computed tomography, EC Working Document EUR 16262. Brussels: EC, 1998.
    • (1998) Quality Criteria for Computed Tomography
  • 5
    • 0032599804 scopus 로고    scopus 로고
    • Dosimetry for optimisation of patient protection in computed tomography
    • Jessen KA, Shrimpton PC, Geleijns P, et al. Dosimetry for optimisation of patient protection in computed tomography. Appl Radiat Isot 1999;50:165-72.
    • (1999) Appl Radiat Isot , vol.50 , pp. 165-172
    • Jessen, K.A.1    Shrimpton, P.C.2    Geleijns, P.3
  • 8
    • 0003179174 scopus 로고
    • 1990 recommendations of the ICRP, ICRP publication 60
    • International Commission on Radiological Protection. 1990 recommendations of the ICRP, ICRP Publication 60. Ann ICRP 1991;21(No. 3):1-3.
    • (1991) Ann ICRP , vol.21 , Issue.3 , pp. 1-3
  • 9
    • 0030732612 scopus 로고    scopus 로고
    • CT standard protocols are of limited value in assessing actual patient dose
    • Wade JP, Weyman JC, Goldstone KE. CT standard protocols are of limited value in assessing actual patient dose. Br J Radiol 1997;70:1146-51.
    • (1997) Br J Radiol , vol.70 , pp. 1146-1151
    • Wade, J.P.1    Weyman, J.C.2    Goldstone, K.E.3
  • 11
    • 0030932827 scopus 로고    scopus 로고
    • Survey of CT techniques and absorbed dose in various dutch hospitals
    • Van Unnik JG, Broerse JJ, Geleijns J, et al. Survey of CT techniques and absorbed dose in various Dutch hospitals. Br J Radiol 1997;70:367-71.
    • (1997) Br J Radiol , vol.70 , pp. 367-371
    • Van Unnik, J.G.1    Broerse, J.J.2    Geleijns, J.3
  • 12
    • 0029824943 scopus 로고    scopus 로고
    • Evaluation of image quality using 1 : 1 pitch and 1.5 : 1 pitch helical CT in children: A comparative study
    • Vade A, Demos TC, Olson MC, et al. Evaluation of image quality using 1 : 1 pitch and 1.5 : 1 pitch helical CT in children: a comparative study. Pediatr Radiol 1996;26:891-3.
    • (1996) Pediatr Radiol , vol.26 , pp. 891-893
    • Vade, A.1    Demos, T.C.2    Olson, M.C.3
  • 13
    • 0030666397 scopus 로고    scopus 로고
    • CT scanning of the paranasal sinuses - The effect of reducing mAs
    • Kearney SE, Jones P, Meakin K, Garvey CJ. CT scanning of the paranasal sinuses - the effect of reducing mAs. Br J Radiol 1997;70:1071-4.
    • (1997) Br J Radiol , vol.70 , pp. 1071-1074
    • Kearney, S.E.1    Jones, P.2    Meakin, K.3    Garvey, C.J.4
  • 14
    • 0030932828 scopus 로고    scopus 로고
    • A survey of routine head Ct protocols in Australia
    • Smith AN, Shah GA. A survey of routine head CT protocols in Australia. Br J Radiol 1997;70:372-4.
    • (1997) Br J Radiol , vol.70 , pp. 372-374
    • Smith, A.N.1    Shah, G.A.2
  • 15
    • 0030666397 scopus 로고    scopus 로고
    • CT scanning of the paranasal sinuses - The effect of reducing mAs
    • Kearney SE, Jones P, Meakin K, Garvey CJ. CT scanning of the paranasal sinuses - the effect of reducing mAs. Br J Radiol 1997;70:1071-4.
    • (1997) Br J Radiol , vol.70 , pp. 1071-1074
    • Kearney, S.E.1    Jones, P.2    Meakin, K.3    Garvey, C.J.4
  • 16
    • 0030932828 scopus 로고    scopus 로고
    • A survey of routine head Ct protocols in Australia
    • Smith AN, Shah GA. A survey of routine head CT protocols in Australia. Br J Radiol 1997;70:372-4.
    • (1997) Br J Radiol , vol.70 , pp. 372-374
    • Smith, A.N.1    Shah, G.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.