메뉴 건너뛰기




Volumn 22, Issue 11, 1999, Pages 1683-1687

'Optimum' formulae for heart rate correction of the QT interval

Author keywords

Heart rate correction; Linear regression analysis; Nonlinear models; QT interval

Indexed keywords

ELECTROPHYSIOLOGY; HEART RATE; HUMAN; MEASUREMENT; QT INTERVAL; REGRESSION ANALYSIS; REVIEW; RR INTERVAL; STATISTICAL MODEL;

EID: 0032708361     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1999.tb00390.x     Document Type: Review
Times cited : (66)

References (14)
  • 1
    • 0001127258 scopus 로고
    • An analysis of the time-relations of electrocardiograms
    • 1. Bazett HC. An analysis of the time-relations of electrocardiograms. Heart 1920; 7:353-367.
    • (1920) Heart , vol.7 , pp. 353-367
    • Bazett, H.C.1
  • 2
    • 0009485512 scopus 로고    scopus 로고
    • Dependence of resting QTc interval on clinical characteristics of survivors of acute myocardial infarction: Comparison of rate correction formula
    • 2. Kautzner J, Hnatkova K, Camm AJ, et al. Dependence of resting QTc interval on clinical characteristics of survivors of acute myocardial infarction: Comparison of rate correction formula. (abstract) PACE 1997; 20:1133.
    • (1997) PACE , vol.20 , pp. 1133
    • Kautzner, J.1    Hnatkova, K.2    Camm, A.J.3
  • 3
    • 84980098899 scopus 로고
    • Die systolendauer im elektrokardiogramm bei normalen menschen und bei herzkranken
    • 3. Fridericia LS. Die Systolendauer im Elektrokardiogramm bei normalen Menschen und bei Herzkranken. Acta Med Scan 1920; 53:469-486.
    • (1920) Acta Med Scan , vol.53 , pp. 469-486
    • Fridericia, L.S.1
  • 4
    • 0021716709 scopus 로고
    • Relation between QT interval and heart rate. Applications and limitations of Bazett's formula
    • 4. Kawataki M, Kashima T, Toda H, et al. Relation between QT interval and heart rate. Applications and limitations of Bazett's formula. J Electrocardiol 1984; 17:371-376.
    • (1984) J Electrocardiol , vol.17 , pp. 371-376
    • Kawataki, M.1    Kashima, T.2    Toda, H.3
  • 5
    • 0026722151 scopus 로고
    • An improved method for adjusting the QT interval for heart rate (the Framingham heart study)
    • 5. Sagie A, Larson MG, Goldberg RJ, et al. An improved method for adjusting the QT interval for heart rate (the Framingham Heart Study). Am J Cardiol 1992; 70:797-801.
    • (1992) Am J Cardiol , vol.70 , pp. 797-801
    • Sagie, A.1    Larson, M.G.2    Goldberg, R.J.3
  • 6
    • 0027218947 scopus 로고
    • Rate-corrected QT interval: Techniques and limitations
    • 6. Funck-Bretano C, Jaillon P. Rate-corrected QT interval: Techniques and limitations. Am J Cardiol 1993; 72:17B-22B.
    • (1993) Am J Cardiol , vol.72
    • Funck-Bretano, C.1    Jaillon, P.2
  • 7
    • 0028358346 scopus 로고
    • Relation between QT intervals and heart rates from 40 to 120 beats/min in rest electrocardiograms of men and a simple method to adjust QT interval values
    • 7. Karjalainen J, Viitasalo M, Mänttäri M, et al. Relation between QT intervals and heart rates from 40 to 120 beats/min in rest electrocardiograms of men and a simple method to adjust QT interval values. J Am Coll Cardiol 1994; 23:1547-1553.
    • (1994) J Am Coll Cardiol , vol.23 , pp. 1547-1553
    • Karjalainen, J.1    Viitasalo, M.2    Mänttäri, M.3
  • 8
    • 76949130639 scopus 로고
    • The measurement of the Q-T interval of the electrocardiogram
    • 8. Lepeschkin E, Surawicz B. The measurement of the Q-T interval of the electrocardiogram. Circulation 1952; 6:378-388.
    • (1952) Circulation , vol.6 , pp. 378-388
    • Lepeschkin, E.1    Surawicz, B.2
  • 9
    • 0025687840 scopus 로고
    • Estimation of QT prolongation: A persistent, avoidable error in computer electrocardiography
    • 9. Rautaharju PM, Warren JW, Calhoun HP. Estimation of QT prolongation: A persistent, avoidable error in computer electrocardiography. J Electrocardiol 1990; 23(Suppl.):111-117.
    • (1990) J Electrocardiol , vol.23 , Issue.SUPPL. , pp. 111-117
    • Rautaharju, P.M.1    Warren, J.W.2    Calhoun, H.P.3
  • 10
    • 0022198211 scopus 로고
    • Correction of the QT interval for heart rate: Review of different formulas and the use of Bazett's formula in myocardial infarction
    • 10. Ahnve S. Correction of the QT interval for heart rate: Review of different formulas and the use of Bazett's formula in myocardial infarction. Am Heart J 1985; 109:568-574.
    • (1985) Am Heart J , vol.109 , pp. 568-574
    • Ahnve, S.1
  • 11
    • 0027296372 scopus 로고
    • Measurement of the QT interval and the risk associated with QTc interval prolongation: A review
    • 11. Moss AJ. Measurement of the QT interval and the risk associated with QTc interval prolongation: A review. Am J Cardiol 1993; 73:23B-25B.
    • (1993) Am J Cardiol , vol.73
    • Moss, A.J.1
  • 12
    • 0030162304 scopus 로고    scopus 로고
    • Correct the QT interval correctly. QTc should be expressed in the same unit as the QT interval
    • 12. Moss AJ. Correct the QT interval correctly. QTc should be expressed in the same unit as the QT interval. PACE 1996; 19:881-882.
    • (1996) PACE , vol.19 , pp. 881-882
    • Moss, A.J.1
  • 13
    • 0030278389 scopus 로고    scopus 로고
    • Correct the QT interval correctly: Should QTc be expressed in the same unit as the QT interval?
    • 13. Malik M, Camm AJ. Correct the QT interval correctly: Should QTc be expressed in the same unit as the QT interval? PACE 1996; 19:1531-1534.
    • (1996) PACE , vol.19 , pp. 1531-1534
    • Malik, M.1    Camm, A.J.2
  • 14
    • 0028918427 scopus 로고
    • The missing second: What is the correct unit for the Bazett corrected QT interval?
    • 14. Molnar J, Weiss JS, Rosenthal JE. The missing second: What is the correct unit for the Bazett corrected QT interval? Am J Cardiol 1995; 75: 537-538.
    • (1995) Am J Cardiol , vol.75 , pp. 537-538
    • Molnar, J.1    Weiss, J.S.2    Rosenthal, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.