메뉴 건너뛰기




Volumn 39, Issue 3, 1999, Pages 225-233

Calorimeter for measuring AC losses in HTS cables for superconducting power transmission lines

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC LOSSES; HIGH TEMPERATURE SUPERCONDUCTORS; SUPERCONDUCTING ELECTRIC LINES;

EID: 0032688785     PISSN: 00112275     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0011-2275(99)00017-X     Document Type: Article
Times cited : (14)

References (14)
  • 3
    • 85031627072 scopus 로고    scopus 로고
    • Single-phase AC losses in prototype HTS conductors for superconducting power transmission lines
    • Proceedings of the ICMC 98 Topical Conf. on AC Loss & Stability (in press)
    • Daney DE, Maley MP, Boenig HJ, Willis JO, Coulter JY, Gherardi L, Coletta G. Single-phase AC losses in prototype HTS conductors for superconducting power transmission lines. Proceedings of the ICMC 98 Topical Conf. on AC Loss & Stability. Physica C (in press).
    • Physica C
    • Daney, D.E.1    Maley, M.P.2    Boenig, H.J.3    Willis, J.O.4    Coulter, J.Y.5    Gherardi, L.6    Coletta, G.7
  • 4
    • 0345215100 scopus 로고
    • Alternating current power losses in superconducting Nb-Zr alloys
    • Wisseman W.R., Boatner L.A., Low F.J. Alternating current power losses in superconducting Nb-Zr alloys. J. Appl. Phys. 35:1964;2649.
    • (1964) J. Appl. Phys. , vol.35 , pp. 2649
    • Wisseman, W.R.1    Boatner, L.A.2    Low, F.J.3
  • 5
    • 0015161280 scopus 로고
    • Alternating current losses in thin film superconductors: New calorimeter measurement technique
    • Meyer C.H. Jr., Snowder D.P., Sterling S.A. Alternating current losses in thin film superconductors: new calorimeter measurement technique. Rev. Sci. Instrum. 42:1971;1584.
    • (1971) Rev. Sci. Instrum. , vol.42 , pp. 1584
    • Meyer C.H., Jr.1    Snowder, D.P.2    Sterling, S.A.3
  • 6
    • 0016507943 scopus 로고
    • Variable temperature apparatus using a thermal conductivity measurement technique for the determination of superconducting AC power loss
    • McConnell R.D., Critchlow P.R. Variable temperature apparatus using a thermal conductivity measurement technique for the determination of superconducting AC power loss. Rev. Sci. Instrum. 46:1975;511.
    • (1975) Rev. Sci. Instrum. , vol.46 , pp. 511
    • McConnell, R.D.1    Critchlow, P.R.2
  • 7
    • 0024139553 scopus 로고
    • Effects of oxidation and roughness on Cu contact resistance from 4 K to 290 K
    • Nilles M.J., Van Sciver S.W. Effects of oxidation and roughness on Cu contact resistance from 4 K to 290 K. Advances in Cryogenic Engineering. 34:1988;443-450.
    • (1988) Advances in Cryogenic Engineering , vol.34 , pp. 443-450
    • Nilles, M.J.1    Van Sciver, S.W.2
  • 8
  • 10
    • 0015669737 scopus 로고
    • Heat transfer and thermal exchange processes in low temperature current leads
    • Odenov S.V. Heat transfer and thermal exchange processes in low temperature current leads. Cryogenics. 13:1973;543-549.
    • (1973) Cryogenics , vol.13 , pp. 543-549
    • Odenov, S.V.1
  • 11
    • 36849129769 scopus 로고
    • Optimum input leads for cryogenic apparatus
    • McFee R. Optimum input leads for cryogenic apparatus. Rev. Sci. Instrum. 30:1959;000.
    • (1959) Rev. Sci. Instrum. , vol.30 , pp. 000
    • McFee, R.1
  • 12
    • 85031627339 scopus 로고
    • Proces-Verbaux Comite Intern
    • Proces-Verbaux Comite Intern. Poids et Mesures 1948;21:T84.
    • (1948) Poids et Mesures , vol.21


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.