메뉴 건너뛰기




Volumn 121, Issue 3, 1999, Pages 162-170

Heat and mass transfer in packed bed liquid desiccant regenerators—an experimental investigation

Author keywords

[No Author keywords available]

Indexed keywords

ALCOHOLS; COOLING; EVAPORATION; HEAT TRANSFER; MASS TRANSFER; PACKED BEDS; PRESSURE DROP; SOLAR COLLECTORS; WATER;

EID: 0032678967     PISSN: 01996231     EISSN: 15288986     Source Type: Journal    
DOI: 10.1115/1.2888428     Document Type: Article
Times cited : (55)

References (26)
  • 1
    • 0346765987 scopus 로고
    • Ambient pressure, liquid desiccant air conditioner
    • Albers, W. F., Beckman, J. R., Farmer, R. W., Gee, K. G., 1991, “Ambient Pressure, Liquid Desiccant Air Conditioner,” ASHRAE Transactions, Vol. 97, pt. 2, pp. 603-608.
    • (1991) ASHRAE Transactions , vol.97 , Issue.2 , pp. 603-608
    • Albers, W.F.1    Beckman, J.R.2    Farmer, R.W.3    Gee, K.G.4
  • 2
    • 0028739371 scopus 로고
    • Predictions of the moisture removal efficiencies for packed-bed dehumidification systems
    • Chung, T.-W., 1994, “Predictions of the Moisture Removal Efficiencies for Packed-Bed Dehumidification Systems,” Gas Separation & Purification, Vol. 8, No. 4, pp. 265-268.
    • (1994) Gas Separation & Purification , vol.8 , Issue.4 , pp. 265-268
    • Chung, T.-W.1
  • 3
    • 0347178746 scopus 로고
    • Dow Chemical Company, Midland, Michigan
    • Dow Chemical Company, 1992, A Guide to Glycols, Dow Chemical Company, Midland, Michigan.
    • (1992) A Guide to Glycols
  • 4
    • 0028466571 scopus 로고
    • Experimental study on the performance of a regeneration tower for various climatic conditions
    • Ertas, A., Gandhidasan, P., Kiris, I., and Anderson, E. E., 1994, “Experimental Study on the Performance of a Regeneration Tower for Various Climatic Conditions,” Solar Energy, Vol. 53, No. 1, pp. 125-130.
    • (1994) Solar Energy , vol.53 , Issue.1 , pp. 125-130
    • Ertas, A.1    Gandhidasan, P.2    Kiris, I.3    Anderson, E.E.4
  • 5
    • 0028500227 scopus 로고
    • Performance analysis of an open-cycle liquid desiccant cooling system using solar energy for regeneration
    • Gandhidasan, P., 1994, “Performance Analysis of an Open-Cycle Liquid Desiccant Cooling System Using Solar Energy for Regeneration,” International Journal of Refrigeration, Vol. 77, No, 7, pp. 475-480.
    • (1994) International Journal of Refrigeration , vol.77 , Issue.7 , pp. 475-480
    • Gandhidasan, P.1
  • 6
    • 0025513015 scopus 로고
    • Reconcentration of aqueous solutions in a packed bed: A simple approach
    • Gandhidasan, P., 1990, “Reconcentration of Aqueous Solutions in a Packed Bed: A Simple Approach,” ASME Journal of Solar Energy Engineering, Vol. 112, pp. 268-272.
    • (1990) ASME Journal of Solar Energy Engineering , vol.112 , pp. 268-272
    • Gandhidasan, P.1
  • 7
    • 0028501819 scopus 로고
    • Sensitivity analysis and component modeling of a packed- type liquid desiccant system at partial load operating conditions
    • Khan, A. Y., 1994. “Sensitivity Analysis and Component Modeling of a Packed- Type Liquid Desiccant System at Partial Load Operating Conditions,” International Journal of Energy Research, Vol. 18, pp. 643-655.
    • (1994) International Journal of Energy Research , vol.18 , pp. 643-655
    • Khan, A.Y.1
  • 8
    • 0030269115 scopus 로고    scopus 로고
    • Proposed energy- efficient air-conditioning system using liquid desiccant
    • Kinsara, A. A., Elsayed, M. M., and Al-Rabghi, O. M., 1996, “Proposed Energy- Efficient Air-Conditioning System Using Liquid Desiccant,” Applied Thermal Engineering, Vol. 16, no. 10, pp. 791-806.
    • (1996) Applied Thermal Engineering , vol.16 , Issue.10 , pp. 791-806
    • Kinsara, A.A.1    Elsayed, M.M.2    Al-Rabghi, O.M.3
  • 9
    • 0002477246 scopus 로고
    • Uncertainties in single-sample experiments
    • Kline, S. J., and McClintock, F. A., 1953, “Uncertainties in Single-Sample Experiments,” Mechanical Engineering, Vol. 75, pp. 3-8.
    • (1953) Mechanical Engineering , vol.75 , pp. 3-8
    • Kline, S.J.1    McClintock, F.A.2
  • 10
    • 0021531734 scopus 로고
    • Coefficients of heat and mass transfer in a packed bed suitable for solar regeneration of aqueous lithium chloride solutions
    • Lttf, G. O. G., Lenz, T. G., and Rao, S., 1984, “Coefficients of Heat and Mass Transfer in a Packed Bed Suitable for Solar Regeneration of Aqueous Lithium Chloride Solutions,” ASME Journal of Solar Energy Engineering, Vol. 106, pp. 387-392.
    • (1984) ASME Journal of Solar Energy Engineering , vol.106 , pp. 387-392
    • Lttf, G.1    Lenz, T.G.2    Rao, S.3
  • 11
    • 0041659759 scopus 로고
    • Liquid desiccant for residential applications
    • Marsala, J., Lowenstein, A., and Ryan, W. A., 1989, “Liquid Desiccant for Residential Applications,” ASHRAE Transactions, Vol. 95, pt. 1, pp. 828-834.
    • (1989) ASHRAE Transactions , vol.95 , Issue.1 , pp. 828-834
    • Marsala, J.1    Lowenstein, A.2    Ryan, W.A.3
  • 13
    • 0009139314 scopus 로고    scopus 로고
    • A review of liquid desiccant cooling
    • Karl W. Boer, editor, American Solar Energy Society, Boulder, Colorado
    • Öberg, V., and Goswami, D. Y., 1998a, “A Review of Liquid Desiccant Cooling,” Advances in Solar Energy, Vol. 12, Karl W. Boer, editor, American Solar Energy Society, Boulder, Colorado, pp. 346-385.
    • (1998) Advances in Solar Energy , vol.12 , pp. 346-385
    • Öberg, V.1    Goswami, D.Y.2
  • 14
    • 0031618312 scopus 로고    scopus 로고
    • Performance simulation of solar hybrid liquid desiccant cooling for ventilation air preconditioning
    • New Mexico
    • Öberg, V., and Goswami, D. Y., 1998b, “Performance Simulation of Solar Hybrid Liquid Desiccant Cooling for Ventilation Air Preconditioning,” Solar Engineering— 1998, Proceedings of the 16th Annual ASME Conference, New Mexico, pp. 176-182.
    • (1998) Solar Engineering— 1998, Proceedings of the 16Th Annual ASME Conference , pp. 176-182
    • Öberg, V.1    Goswami, D.Y.2
  • 15
    • 0032208917 scopus 로고    scopus 로고
    • Experimental study of the heat and mass transfer in a packed bed liquid desiccant air dehumiditier
    • Öberg, V., and Goswami, D. Y., 1998c, “Experimental Study of the Heat and Mass Transfer in a Packed Bed Liquid Desiccant Air Dehumiditier,” ASME Journal op Solar Energy Engineering, Vol. 120, pp. 289-297.
    • (1998) ASME Journal Op Solar Energy Engineering , vol.120 , pp. 289-297
    • Öberg, V.1    Goswami, D.Y.2
  • 16
    • 84985656751 scopus 로고
    • Mass transfer coefficients between gas and liquid phases in packed columns
    • Onda, K., Takeuchi, H., and Okumoto, Y., 1968, “Mass Transfer Coefficients Between Gas and Liquid Phases in Packed Columns,” Journal of Chemical Engineering of Japan, Vol. 1, No. 1, pp. 56-62.
    • (1968) Journal of Chemical Engineering of Japan , vol.1 , Issue.1 , pp. 56-62
    • Onda, K.1    Takeuchi, H.2    Okumoto, Y.3
  • 17
    • 0025529847 scopus 로고
    • Performance studies for an experimental solar open-cycle liquid desiccant air dehumidification system
    • Patnaik, S., Lenz, T. G., and Lof, G. O. G., 1990, “Performance Studies for an Experimental Solar Open-Cycle Liquid Desiccant Air Dehumidification System,” Solar Energy, Vol. 44, No. 3, pp. 123-135.
    • (1990) Solar Energy , vol.44 , Issue.3 , pp. 123-135
    • Patnaik, S.1    Lenz, T.G.2    Lof, G.3
  • 18
    • 0021427752 scopus 로고
    • The performance of various types of regenerators for liquid desiccants
    • Peng, C. S. P., and Howell, J. R., 1984, ‘The Performance of Various Types of Regenerators for Liquid Desiccants,” ASME Journal of Solar Energy Engineering, Vol. 106, pp. 133-141.
    • (1984) ASME Journal of Solar Energy Engineering , vol.106 , pp. 133-141
    • Peng, C.1    Howell, J.R.2
  • 19
    • 0030290696 scopus 로고    scopus 로고
    • Dimensionless mass transfer correlations for packed-bed liquid-desiccant contactors
    • Potnis, S. V., and Lenz, T. G., 1996, “Dimensionless Mass Transfer Correlations for Packed-Bed Liquid-Desiccant Contactors.” Industrial and Engineering Chemistry Research, Vol. 35, pp. 4185-4193.
    • (1996) Industrial and Engineering Chemistry Research , vol.35 , pp. 4185-4193
    • Potnis, S.V.1    Lenz, T.G.2
  • 20
    • 0018062223 scopus 로고
    • Liquid sorbent solar air conditioner
    • Veziroju, T. N., editor. Hemisphere Publishing Company, Washington, DC
    • Robison, H., 1977, “Liquid Sorbent Solar Air Conditioner,” Alternative Energy Sources, Vol. 2, Veziroju, T. N., editor. Hemisphere Publishing Company, Washington, DC, pp. 761-779.
    • (1977) Alternative Energy Sources , vol.2 , pp. 761-779
    • Robison, H.1
  • 21
    • 0025031336 scopus 로고
    • A liquid sorption-desorption system for air conditioning with heat at lower temperature
    • Scalabrin, G., and Scaltriti, G., 1990, “A Liquid Sorption-Desorption System for Air Conditioning With Heat at Lower Temperature,” ASME Journal of Solar Energy Engineering, Vol. 112, pp. 70-75.
    • (1990) ASME Journal of Solar Energy Engineering , vol.112 , pp. 70-75
    • Scalabrin, G.1    Scaltriti, G.2
  • 22
    • 0023828925 scopus 로고
    • Analysis of the seasonal performance of hybrid liquid desiccant cooling systems
    • Sick, F., Buschulte, T. K., Klein, P., Northey, P., and Duffie, J. A., 1988, “Analysis of the Seasonal Performance of Hybrid Liquid Desiccant Cooling Systems,” Solar Energy, Vol. 40, pp. 211-217.
    • (1988) Solar Energy , vol.40 , pp. 211-217
    • Sick, F.1    Buschulte, T.K.2    Klein, P.3    Northey, P.4    Duffie, J.A.5
  • 23
    • 0008516942 scopus 로고
    • An economic analysis of a solar open cycle desiccant dehumidification system
    • Thornbloom, M., and Nimmo, B., 1995, “An Economic Analysis of a Solar Open Cycle Desiccant Dehumidification System,” Solar Engineering—1995, Proceedings of the 13th Annual ASME Conference, Hawaii, Vol. 1, pp. 705-709.
    • (1995) Solar Engineering , vol.1 , pp. 705-709
    • Thornbloom, M.1    Nimmo, B.2
  • 25
    • 0014539146 scopus 로고
    • Adiabatic gas absorption and stripping in packed towers
    • Treybal, R. E., 1969, “Adiabatic Gas Absorption and Stripping in Packed Towers,” Industrial and Engineering Chemistry, Vol. 61, no. 7, pp. 36-41.
    • (1969) Industrial and Engineering Chemistry , vol.61 , Issue.7 , pp. 36-41
    • Treybal, R.E.1
  • 26
    • 0023742017 scopus 로고
    • Effectiveness of moisture removal for an adiabatic counterflow packed tower absorber operating with cacl2-air contact system
    • lillah, M. R., Kettleborough, C. F., and Gandhidasan, P., 1988, “Effectiveness of Moisture Removal for an Adiabatic Counterflow Packed Tower Absorber Operating with CaCl2-Air Contact System,” ASME Journal of Solar Energy Engineering, Vol. 110, pp. 98-101.
    • (1988) ASME Journal of Solar Energy Engineering , vol.110 , pp. 98-101
    • Lillah, M.R.1    Kettleborough, C.F.2    Gandhidasan, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.