메뉴 건너뛰기




Volumn 22, Issue 5, 1999, Pages 442-451

Reducing running costs in air conditioning

Author keywords

[No Author keywords available]

Indexed keywords

AZEOTROPES; COST EFFECTIVENESS; ELECTRIC POWER UTILIZATION; MATHEMATICAL MODELS; REFRIGERANTS;

EID: 0032672908     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0140-7007(98)00068-1     Document Type: Article
Times cited : (12)

References (8)
  • 1
    • 0344988255 scopus 로고
    • An experimental study of the use of mixed refrigerants for non-isothermal refrigeration
    • Haselden G.G., Klimek L. An experimental study of the use of mixed refrigerants for non-isothermal refrigeration. Proc. Inst. Refrig. 54:1957;129-148.
    • (1957) Proc. Inst. Refrig. , vol.54 , pp. 129-148
    • Haselden, G.G.1    Klimek, L.2
  • 2
    • 0344988253 scopus 로고
    • Mixed refrigerants for air conditioning and heat pumping
    • Chen J., Haselden G.G. Mixed refrigerants for air conditioning and heat pumping. Proc. Inst. Refrig. 3:1992;1-10.
    • (1992) Proc. Inst. Refrig. , vol.3 , pp. 1-10
    • Chen, J.1    Haselden, G.G.2
  • 3
    • 0028501322 scopus 로고
    • Wide boiling refrigerant mixtures for energy saving
    • Bensafi A, Haselden G.G. Wide boiling refrigerant mixtures for energy saving. Proc. Inst. Refrig. 17:1994;469-474.
    • (1994) Proc. Inst. Refrig. , vol.17 , pp. 469-474
    • Bensafi, A.1    Haselden, G.G.2
  • 4
    • 49149138365 scopus 로고
    • The advantages of using non-azeotropic refrigerant mixtures for heat pump application
    • Kruse H. The advantages of using non-azeotropic refrigerant mixtures for heat pump application. Int. J. Refrig. 4:(3):1981;119-125.
    • (1981) Int. J. Refrig. , vol.4 , Issue.3 , pp. 119-125
    • Kruse, H.1
  • 6
    • 43949155081 scopus 로고
    • Glide matching with binary and ternary zeotropic refrigerant mixtures (Part 1)-An experimental study
    • Mulroy W., Domanski P.A., Didion D.A. Glide matching with binary and ternary zeotropic refrigerant mixtures (Part 1)-An experimental study. Int. J. Refrig. 17:(4):1994;220-225.
    • (1994) Int. J. Refrig. , vol.17 , Issue.4 , pp. 220-225
    • Mulroy, W.1    Domanski, P.A.2    Didion, D.A.3
  • 7
    • 0344988252 scopus 로고    scopus 로고
    • The use of wide-boiling mixed refrigerants in air conditioning and water chiller applications., IChemE Research Event
    • Lamb R.A., Carter K.L., Foumeny E.A., Haselden G.G. The use of wide-boiling mixed refrigerants in air conditioning and water chiller applications., IChemE Research Event. Nottingham. 1:1997;577-580.
    • (1997) Nottingham , vol.1 , pp. 577-580
    • Lamb, R.A.1    Carter, K.L.2    Foumeny, E.A.3    Haselden, G.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.