메뉴 건너뛰기




Volumn , Issue 1346, 1999, Pages 266-273

Characterization of carbon fiber-reinforced peek composite for use as a bearing material in total hip replacements

Author keywords

[No Author keywords available]

Indexed keywords

BIOMATERIALS; CARBON FIBER REINFORCED PLASTICS; COMPUTER SIMULATION; IMPLANTS (SURGICAL); INJECTION MOLDING; MATERIALS TESTING; MECHANICAL PROPERTIES; ORTHOPEDICS; POLYETHER ETHER KETONES; STRESS ANALYSIS; TRIBOLOGY; WEAR OF MATERIALS;

EID: 0032670374     PISSN: 10403094     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Article
Times cited : (7)

References (11)
  • 1
    • 85012762982 scopus 로고
    • Composites for aerospace dry bearing applications
    • K. Friedrich (Ed.), Elsevier, Amsterdam
    • Lancaster, J. K., "Composites for aerospace dry bearing applications," in Friction and Wear of Polymer Composites, K. Friedrich (Ed.), Elsevier, Amsterdam, 1986, pp.363-396.
    • (1986) Friction and Wear of Polymer Composites , pp. 363-396
    • Lancaster, J.K.1
  • 2
    • 85023396114 scopus 로고
    • Tribological properties of selected polymeric matrix composites against steel surfaces
    • K. Friedrich (Ed.), Elsevier, Amsterdam
    • Thorp, J. M., "Tribological properties of selected polymeric matrix composites against steel surfaces," in Friction and Wear of Polymer Composites, K. Friedrich (Ed.), Elsevier, Amsterdam, 1986, pp.89-136.
    • (1986) Friction and Wear of Polymer Composites , pp. 89-136
    • Thorp, J.M.1
  • 3
    • 36149060809 scopus 로고
    • The effect of carbon fiber reinforcement on the friction and wear of polymers
    • Lancaster, J. K., "The effect of carbon fiber reinforcement on the friction and wear of polymers," British Journal of Applied Physics, 1, 5, 1968, 549.
    • (1968) British Journal of Applied Physics , vol.1 , Issue.5 , pp. 549
    • Lancaster, J.K.1
  • 4
    • 85012735140 scopus 로고
    • Friction and wear of unidirectionally oriented glass, carbon, aramid and stainless steel fiber-reinforced plastics
    • K. Friedrich (Ed.), Elsevier, Amsterdam
    • Tsukizoe, T. and Ohmae, N., "Friction and wear of unidirectionally oriented glass, carbon, aramid and stainless steel fiber-reinforced plastics," in K. Friedrich (Ed.), Friction and Wear of Polymer Composites, Elsevier, Amsterdam, 1986, pp.205-232.
    • (1986) Friction and Wear of Polymer Composites , pp. 205-232
    • Tsukizoe, T.1    Ohmae, N.2
  • 5
    • 0029414205 scopus 로고
    • Recent advances in polymer composites tribology
    • Friedrich, K., Lu, Z. and Hager, A. M., "Recent advances in polymer composites tribology," Wear, 190, 1995, pp. 139-144.
    • (1995) Wear , vol.190 , pp. 139-144
    • Friedrich, K.1    Lu, Z.2    Hager, A.M.3
  • 7
    • 0019620832 scopus 로고
    • The effect of carbon fiber reinforcement on contact area, contact pressure, and time-dependent deformation in polyethylene tibial components
    • Wright, T. M., Fukubayashi, T. and Burstein, A. H., "The effect of carbon fiber reinforcement on contact area, contact pressure, and time-dependent deformation in polyethylene tibial components," Journal of Biomedical Materials Research, Vol. 15, 1981, pp. 719-730.
    • (1981) Journal of Biomedical Materials Research , vol.15 , pp. 719-730
    • Wright, T.M.1    Fukubayashi, T.2    Burstein, A.H.3
  • 8
    • 0028249112 scopus 로고
    • A hip wear simulator for the evaluation of biomaterials in hip-arthroplasty components
    • Mejia, L. C. and Brierley, T. J., "A hip wear simulator for the evaluation of biomaterials in hip-arthroplasty components," Biomedical Materials and Engineering, 4, 1994, pp. 259-271.
    • (1994) Biomedical Materials and Engineering , vol.4 , pp. 259-271
    • Mejia, L.C.1    Brierley, T.J.2
  • 9
    • 77949504506 scopus 로고
    • Loading on normal hip and knee joints and on joint replacements
    • M. Schaldach and D. Hohman (eds.), Springer-Verlag, New York
    • Paul, J., "Loading on normal hip and knee joints and on joint replacements," Engineering in Medicine, Vol. 2, Advances in Artificial Hip and Knee Joint Technology, M. Schaldach and D. Hohman (eds.), Springer-Verlag, New York, 1976.
    • (1976) Engineering in Medicine, Vol. 2, Advances in Artificial Hip and Knee Joint Technology , vol.2
    • Paul, J.1
  • 10
    • 0002591099 scopus 로고
    • Evolution and evaluation of materials-screening machines and joint simulators in predicting in vivo wear phenomena
    • Applications, P. Ducheyne and G. Hastings (eds.), CRC Press
    • McKellop, H. and Clarke, I. C., "Evolution and evaluation of materials-screening machines and joint simulators in predicting in vivo wear phenomena," Functional Behavior of Orthopaedic Biomaterials, Vol. II, Applications, P. Ducheyne and G. Hastings (eds.), CRC Press, 1984.
    • (1984) Functional Behavior of Orthopaedic Biomaterials , vol.2
    • McKellop, H.1    Clarke, I.C.2
  • 11
    • 0023007566 scopus 로고
    • The effect of conformity, thickness and material on stresses in ultra-high molecular weight components for total joint replacements
    • Bartel, D. L., Bicknell, V. L. and Wright, T. M., "The effect of conformity, thickness and material on stresses in ultra-high molecular weight components for total joint replacements," Journal of Bone and Joint Surgery, Vol. 68-A, 7, 1986, pp. 1041-1051.
    • (1986) Journal of Bone and Joint Surgery , vol.68 A , Issue.7 , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.