메뉴 건너뛰기




Volumn 146, Issue 2, 1999, Pages 121-124

Transmission line fault location for phase-to-earth fault using one-terminal data

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; ELECTRIC FAULT LOCATION; ELECTRIC LOADS; ELECTRIC RESISTANCE; MATHEMATICAL MODELS;

EID: 0032657442     PISSN: 13502360     EISSN: None     Source Type: Journal    
DOI: 10.1049/ip-gtd:19990174     Document Type: Article
Times cited : (49)

References (9)
  • 1
    • 0022010176 scopus 로고
    • An accurate fault location with compensation for apparent reactance in the fault resistance resulting from remote-end infeed
    • ERIKSSON, L., SAHA, M.M., and ROCKFELLER, G.D.: 'An accurate fault location with compensation for apparent reactance in the fault resistance resulting from remote-end infeed', IEEE Trans. Power Appar. Syst., 1985, PAS-104, (2), pp. 424-436
    • (1985) IEEE Trans. Power Appar. Syst. , vol.PAS-104 , Issue.2 , pp. 424-436
    • Eriksson, L.1    Saha, M.M.2    Rockfeller, G.D.3
  • 2
    • 0020166862 scopus 로고
    • Development of a new type fault locator using the one-terminal voltage and current data
    • TAKAGI, T., YAMAKOSHI, Y., YAMAURA, M., KONDOW, R., and MATSUSHIMA, T.: 'Development of a new type fault locator using the one-terminal voltage and current data', IEEE Trans. Power Appar. Syst., 1982, PAS-101, (8), pp. 2892-2897
    • (1982) IEEE Trans. Power Appar. Syst. , vol.PAS-101 , Issue.8 , pp. 2892-2897
    • Takagi, T.1    Yamakoshi, Y.2    Yamaura, M.3    Kondow, R.4    Matsushima, T.5
  • 3
    • 0030086222 scopus 로고    scopus 로고
    • Automated transmission line fault analysis using synchronized sampling at two end
    • KEZUNOVIC, M., and PERUNICIC, B.: 'Automated transmission line fault analysis using synchronized sampling at two end', IEEE Trans. Power Syst., 1996, PS-11, (1), pp. 441-447
    • (1996) IEEE Trans. Power Syst. , vol.PS-11 , Issue.1 , pp. 441-447
    • Kezunovic, M.1    Perunicic, B.2
  • 4
    • 0029736561 scopus 로고    scopus 로고
    • Unsynchronized two-terminal fault location estimation
    • NOVOSEL, D., HART, D.G., UDREN, E., and GARITTY, J.: 'Unsynchronized two-terminal fault location estimation', IEEE Trans. Power Deliv., 1996, PS-11, (1), pp. 130-136
    • (1996) IEEE Trans. Power Deliv. , vol.PS-11 , Issue.1 , pp. 130-136
    • Novosel, D.1    Hart, D.G.2    Udren, E.3    Garitty, J.4
  • 5
    • 0023844294 scopus 로고
    • A technique for estimating transmission line fault locations from dicital impedance relay measurement
    • SACHDEV, M.S., and AGARWAL, R.: 'A technique for estimating transmission line fault locations from dicital impedance relay measurement', IEEE Trans. Power Deliv., 1988, PD-3, (1), pp. 424-436
    • (1988) IEEE Trans. Power Deliv. , vol.PD-3 , Issue.1 , pp. 424-436
    • Sachdev, M.S.1    Agarwal, R.2
  • 6
    • 0025517399 scopus 로고
    • Accurate fault location technique for power transmission lines
    • JOHNS, A.T., and JAMALI, S.: 'Accurate fault location technique for power transmission lines', IEE Proc. C, 1990, 137, (6), pp. 395-402
    • (1990) IEE Proc. C , vol.137 , Issue.6 , pp. 395-402
    • Johns, A.T.1    Jamali, S.2
  • 7
    • 0023985456 scopus 로고
    • Transmission line fault location using digital fault recorders
    • LAWRENCE, D.J., and WASER, D.L.: Transmission line fault location using digital fault recorders', IEEE Trans. Power Deliv., 1988, 3, (2), pp. 496-501
    • (1988) IEEE Trans. Power Deliv. , vol.3 , Issue.2 , pp. 496-501
    • Lawrence, D.J.1    Waser, D.L.2
  • 8
    • 0032188351 scopus 로고    scopus 로고
    • Transmission line fault location for single phase-to-earth fault on non-direct-ground neutral system
    • ZHANG, Q.C., ZHANG, Y., SONG, W.N., and FANG, D.Z.: Transmission line fault location for single phase-to-earth fault on non-direct-ground neutral system', IEEE Trans. Power Deliv., 1998, 10, (3), pp. 1086-1093
    • (1998) IEEE Trans. Power Deliv. , vol.10 , Issue.3 , pp. 1086-1093
    • Zhang, Q.C.1    Zhang, Y.2    Song, W.N.3    Fang, D.Z.4
  • 9
    • 0032628611 scopus 로고    scopus 로고
    • Fault location of two-parallel transmission line for non-earth fault using one-terminal data
    • New York, USA, Paper 99-WM-433
    • ZHANG, Q.C., ZHANG, Y., SONG, W.N., YU, Y.X., and WANG, Z.G.: 'Fault location of two-parallel transmission line for non-earth fault using one-terminal data'. IEEE PES winter meeting, New York, USA, 1999, Paper 99-WM-433
    • (1999) IEEE PES Winter Meeting
    • Zhang, Q.C.1    Zhang, Y.2    Song, W.N.3    Yu, Y.X.4    Wang, Z.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.