메뉴 건너뛰기




Volumn 146, Issue 1, 1999, Pages 96-100

Determination of the optimum site-matching wind turbine using risk-based capacity benefit factors

Author keywords

[No Author keywords available]

Indexed keywords

RISKS; SPEED; VELOCITY; WIND POWER;

EID: 0032652440     PISSN: 13502360     EISSN: None     Source Type: Journal    
DOI: 10.1049/ip-gtd:19990049     Document Type: Article
Times cited : (29)

References (9)
  • 2
    • 0026912558 scopus 로고
    • Evaluation of short-term wind predictability
    • FERREIRA, L. A.F.M.:'Evaluation of short-term wind predictability', IEEE Trans. Energy Comers., 1992, 3, (7), pp. 409-417
    • (1992) IEEE Trans. Energy Comers. , vol.3 , Issue.7 , pp. 409-417
    • Ferreira, L.A.F.M.1
  • 3
    • 0020497503 scopus 로고
    • Development of a new procedure for reliability modeling of wind turbine generators
    • GIORSETTO, P.,and UTSUROGI, K.F.:'Development of a new procedure for reliability modeling of wind turbine generators',IEEE Trans., Power Appar. Syst., 1983, 1, (102), pp. 134-143
    • (1983) IEEE Trans., Power Appar. Syst. , vol.1 , Issue.102 , pp. 134-143
    • Giorsetto, P.1    Utsurogi, K.F.2
  • 5
    • 0024719222 scopus 로고
    • A reliability test system for educational purposes - Basic data
    • BILLINTON, R.,KUMAR, S.,and CHOWDHURY, N.:'A reliability test system for educational purposes - basic data', IEEE Trans., Power Syst., 1989, 3, (4), pp. 1238-1244
    • (1989) IEEE Trans., Power Syst. , vol.3 , Issue.4 , pp. 1238-1244
    • Billinton, R.1    Kumar, S.2    Chowdhury, N.3
  • 6
    • 0022060780 scopus 로고
    • Reliability modeling of generation system including unconventional energy sources
    • SINGH, C.,and LAGO-GONZALEZ, A.:'Reliability modeling of generation system including unconventional energy sources', IEEE Trans., Power Appar. Syst., 1985, 5, (104), pp. 1049-1056
    • (1985) IEEE Trans., Power Appar. Syst. , vol.5 , Issue.104 , pp. 1049-1056
    • Singh, C.1    Lago-Gonzalez, A.2
  • 7
    • 0026682336 scopus 로고
    • Incorporation of wind energy conversion systems in conventional generating capacity adequacy assessment
    • BILLINTON, R.,and CHOWDHURY, A.A.:'Incorporation of wind energy conversion systems in conventional generating capacity adequacy assessment', IEE Proc. C, 1992, 1, (139), pp. 47-56
    • (1992) IEE Proc. C , vol.1 , Issue.139 , pp. 47-56
    • Billinton, R.1    Chowdhury, A.A.2
  • 8
    • 0030385334 scopus 로고    scopus 로고
    • A sequential simulation technique for adequacy evaluation of generating systems including wind energy
    • BILLINTON, R.,CHEN, H.,and GHAJAR, R.:'A sequential simulation technique for adequacy evaluation of generating systems including wind energy', IEEE Trans. Energy Convers., 1996, 4, (11), pp. 728-734
    • (1996) IEEE Trans. Energy Convers , vol.4 , Issue.11 , pp. 728-734
    • Billinton, R.1    Chen, H.2    Ghajar, R.3
  • 9
    • 0030241740 scopus 로고    scopus 로고
    • Time-series models for reliability evaluation of power systems including wind energy
    • BILLINTON, R.,CHEN, H.,and GHAJAR, R.:'Time-series models for reliability evaluation of power systems including wind energy', Microelectron. Reliab., 1996, 9, (36), pp. 1253-1261
    • (1996) Microelectron. Reliab. , vol.9 , Issue.36 , pp. 1253-1261
    • Billinton, R.1    Chen, H.2    Ghajar, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.