메뉴 건너뛰기




Volumn 54, Issue 6, 1999, Pages 931-942

Determination of selenium in serum and urine by inductively coupled plasma mass spectrometry: Comparison with Zeeman graphite furnace atomic absorption spectrometry

Author keywords

[No Author keywords available]

Indexed keywords

ABSORPTION SPECTROSCOPY; ATOMIC SPECTROSCOPY; BODY FLUIDS; CORRELATION METHODS; REGRESSION ANALYSIS; SELENIUM;

EID: 0032636325     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0584-8547(99)00005-1     Document Type: Article
Times cited : (22)

References (22)
  • 1
    • 0024804261 scopus 로고
    • Selenium: Clinical significance and analytical concepts
    • Lockitch G. Selenium: clinical significance and analytical concepts. Crit. Rev. Clin. Lab. Sci. 27:1989;483-541.
    • (1989) Crit. Rev. Clin. Lab. Sci. , vol.27 , pp. 483-541
    • Lockitch, G.1
  • 2
    • 0021028389 scopus 로고
    • Selenium deficiency with total parenteral nutrition: Reversal of biochemical and functional abnormalities by selenium supplementation: A case report
    • Baker S.S., Lerman R.H., Krey S.H., Crocker K.S., Hirsh E.F., Cohen H. Selenium deficiency with total parenteral nutrition: reversal of biochemical and functional abnormalities by selenium supplementation: a case report. Am. J. Clin. Nutr. 38:1983;769-774.
    • (1983) Am. J. Clin. Nutr. , vol.38 , pp. 769-774
    • Baker, S.S.1    Lerman, R.H.2    Krey, S.H.3    Crocker, K.S.4    Hirsh, E.F.5    Cohen, H.6
  • 3
    • 0027515540 scopus 로고
    • Urinary selenium concentrations
    • Alaejos M.S., Romero C.D. Urinary selenium concentrations. Clin. Chem. 39:1993;2040-2052.
    • (1993) Clin. Chem. , vol.39 , pp. 2040-2052
    • Alaejos, M.S.1    Romero, C.D.2
  • 4
    • 0021340063 scopus 로고
    • Selenium in human urine: Concentration levels and medical implications
    • Robberecht H.J., Deelstra H.A. Selenium in human urine: concentration levels and medical implications. Clin. Chim. Acta. 136:1984;107-120.
    • (1984) Clin. Chim. Acta , vol.136 , pp. 107-120
    • Robberecht, H.J.1    Deelstra, H.A.2
  • 7
    • 0021049604 scopus 로고
    • Determination of selenium in biological materials with platform furnace atomic-absorption spectroscopy and Zeeman background correction
    • Carnrick G.R., Manning D.C., Slavin W. Determination of selenium in biological materials with platform furnace atomic-absorption spectroscopy and Zeeman background correction. Analyst. 108:1983;1297-1312.
    • (1983) Analyst , vol.108 , pp. 1297-1312
    • Carnrick, G.R.1    Manning, D.C.2    Slavin, W.3
  • 8
    • 0019983570 scopus 로고
    • A methodological comparison of hydride and carbon furnace atomic absorption spectroscopy for the determination of selenium in serum
    • Oster O., Prellwitz W. A methodological comparison of hydride and carbon furnace atomic absorption spectroscopy for the determination of selenium in serum. Clin. Chim. Acta. 124:1982;277-291.
    • (1982) Clin. Chim. Acta , vol.124 , pp. 277-291
    • Oster, O.1    Prellwitz, W.2
  • 9
    • 0000414949 scopus 로고
    • Determination of selenium in small volumes of blood plasma and serum by electrothermal atomic absorption spectrometry
    • Alfthan G., Kumpulainen J. Determination of selenium in small volumes of blood plasma and serum by electrothermal atomic absorption spectrometry. Anal. Chim. Acta. 140:1982;221-227.
    • (1982) Anal. Chim. Acta , vol.140 , pp. 221-227
    • Alfthan, G.1    Kumpulainen, J.2
  • 10
    • 0012474027 scopus 로고
    • Is palladium a better matrix modifier than nickel for the Zeeman graphite furnace determination of selenium in serum and urine?
    • [Abstract], Detroit
    • D.E. Nixon, T.P. Moyer, Is palladium a better matrix modifier than nickel for the Zeeman graphite furnace determination of selenium in serum and urine? [Abstract], In: Federation of Analytical Chemistry and Spectroscopy Society, 20th Meeting. Detroit, 1993.
    • (1993) In: Federation of Analytical Chemistry and Spectroscopy Society, 20th Meeting
    • Nixon, D.E.1    Moyer, T.P.2
  • 11
    • 0023890349 scopus 로고
    • Direct determination of selenium in serum by graphite-furnace atomic absorption spectrometry with deuterium background correction and a reduced palladium modifier: Age-specific reference ranges
    • Jacobson B.E., Lockitch G. Direct determination of selenium in serum by graphite-furnace atomic absorption spectrometry with deuterium background correction and a reduced palladium modifier: age-specific reference ranges. Clin. Chem. 34:1988;709-714.
    • (1988) Clin. Chem. , vol.34 , pp. 709-714
    • Jacobson, B.E.1    Lockitch, G.2
  • 12
    • 0023870648 scopus 로고
    • Improved determination of selenium in serum by Zeeman atomic absorption spectrometry
    • Morisi G., Patriarca M., Menotti A. Improved determination of selenium in serum by Zeeman atomic absorption spectrometry. Clin. Chem. 34:1988;127-130.
    • (1988) Clin. Chem. , vol.34 , pp. 127-130
    • Morisi, G.1    Patriarca, M.2    Menotti, A.3
  • 13
    • 0025058263 scopus 로고
    • Automated measurement of two indicators of human selenium status, and applicability to population studies
    • McMaster D., Bell N., Anderson P., Love A.H.G. Automated measurement of two indicators of human selenium status, and applicability to population studies. Clin. Chem. 36:1990;211-216.
    • (1990) Clin. Chem. , vol.36 , pp. 211-216
    • McMaster, D.1    Bell, N.2    Anderson, P.3    Love, A.H.G.4
  • 14
    • 0023845921 scopus 로고
    • Comparison of methods for the determination of selenium in biological fluids
    • Macpherson A.K., Sampson B., Diplock A.T. Comparison of methods for the determination of selenium in biological fluids. Analyst. 113:1988;281-283.
    • (1988) Analyst , vol.113 , pp. 281-283
    • Macpherson, A.K.1    Sampson, B.2    Diplock, A.T.3
  • 15
    • 0024406214 scopus 로고
    • Isotopic determination of selenium in biological materials with inductively coupled plasma mass spectrometry
    • Ting B.T.G., Mooers C.S., Janghorbani M. Isotopic determination of selenium in biological materials with inductively coupled plasma mass spectrometry. Analyst. 114:1989;667-674.
    • (1989) Analyst , vol.114 , pp. 667-674
    • Ting, B.T.G.1    Mooers, C.S.2    Janghorbani, M.3
  • 16
    • 0026843781 scopus 로고
    • Determination of selenium by inductively coupled plasma mass spectrometry utilizing a new hydride generation sample introduction system
    • Buckley W.T., Budac J.J., Godfrey D.V. Determination of selenium by inductively coupled plasma mass spectrometry utilizing a new hydride generation sample introduction system. Anal. Chem. 64:1992;724-729.
    • (1992) Anal. Chem. , vol.64 , pp. 724-729
    • Buckley, W.T.1    Budac, J.J.2    Godfrey, D.V.3
  • 17
    • 0001208974 scopus 로고
    • Elimination of chloride interference on the determination of selenium in serum by inductively coupled plasma mass spectrometry
    • Lyon T.D.B., Fell G.S., Hutton R.C., Eaton A.N. Elimination of chloride interference on the determination of selenium in serum by inductively coupled plasma mass spectrometry. J. Anal. Atom. Spectrom. 3:1988;601-603.
    • (1988) J. Anal. Atom. Spectrom. , vol.3 , pp. 601-603
    • Lyon, T.D.B.1    Fell, G.S.2    Hutton, R.C.3    Eaton, A.N.4
  • 18
    • 37049084331 scopus 로고
    • Evaluation of inductively coupled argon plasma mass spectrometry (ICP-MS) for simultaneous multi-element trace analysis in clinical chemistry
    • Lyon T.D.B., Fell G.S., Hutton R.C., Eaton A.N. Evaluation of inductively coupled argon plasma mass spectrometry (ICP-MS) for simultaneous multi-element trace analysis in clinical chemistry. J. Anal. Atom. Spectrom. 3:1988;265-271.
    • (1988) J. Anal. Atom. Spectrom. , vol.3 , pp. 265-271
    • Lyon, T.D.B.1    Fell, G.S.2    Hutton, R.C.3    Eaton, A.N.4
  • 19
    • 0031100654 scopus 로고    scopus 로고
    • Simple method for the accurate determination of selenium in serum by using inductively coupled plasma mass spectrometry
    • Delves H.T., Sieniawska C.E. Simple method for the accurate determination of selenium in serum by using inductively coupled plasma mass spectrometry. J. Anal. Atom. Spectrom. 12:1997;387-389.
    • (1997) J. Anal. Atom. Spectrom. , vol.12 , pp. 387-389
    • Delves, H.T.1    Sieniawska, C.E.2
  • 21
    • 0345456910 scopus 로고
    • Speciation of selenium in human serum by size exclusion chromatography and inductively coupled plasma mass spectrometry
    • in: D.C. Andrews, A.M.C. Davies (Eds.), Cambridge, UK
    • T.M. Bricker, R.S. Houk, Speciation of selenium in human serum by size exclusion chromatography and inductively coupled plasma mass spectrometry, in: D.C. Andrews, A.M.C. Davies (Eds.), Frontiers in Analytical Spectroscopy, Cambridge, UK, 1995, pp. 109-116.
    • (1995) Frontiers in Analytical Spectroscopy , pp. 109-116
    • Bricker, T.M.1    Houk, R.S.2
  • 22
    • 37049083188 scopus 로고
    • Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciation
    • Larsen E.H., Stuerup S. Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciation. J. Anal. Atom. Spectrom. 9:1994;1099-1105.
    • (1994) J. Anal. Atom. Spectrom. , vol.9 , pp. 1099-1105
    • Larsen, E.H.1    Stuerup, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.