메뉴 건너뛰기




Volumn 27, Issue 1, 1999, Pages 42-47

A "geographic information systems" based technique for the study of microvascular networks

Author keywords

Digital image processing; GIS; Intravital microscopy; Ionizing radiation; Microcirculation; Physiome Project

Indexed keywords

ANIMAL; ARTICLE; AUDIOVISUAL EQUIPMENT; BLOOD RHEOLOGY; HAMSTER; HISTOLOGY; INFORMATION SYSTEM; MALE; MICROCIRCULATION; SYRIAN HAMSTER;

EID: 0032622206     PISSN: 00906964     EISSN: None     Source Type: Journal    
DOI: 10.1114/1.204     Document Type: Article
Times cited : (22)

References (15)
  • 1
    • 0015799838 scopus 로고
    • An open cremaster muscle preparation for the study of blood vessels by in vivo microscopy
    • Baez, S. An open cremaster muscle preparation for the study of blood vessels by in vivo microscopy. Microvasc. Res. 5:384-394, 1973.
    • (1973) Microvasc. Res. , vol.5 , pp. 384-394
    • Baez, S.1
  • 2
    • 0023679457 scopus 로고
    • Vascular lesions following radiation
    • Fajardo, L. F., and M. Berthrong. Vascular lesions following radiation. Pathol. Annu. 23:297-230, 1983.
    • (1983) Pathol. Annu. , vol.23 , pp. 297-1230
    • Fajardo, L.F.1    Berthrong, M.2
  • 4
    • 0028860132 scopus 로고
    • Measurement uncertainties associated with the use of bright-field and fluorescence microscopy in the microcirculation
    • Gretz, J. E., and B. R. Duling. Measurement uncertainties associated with the use of bright-field and fluorescence microscopy in the microcirculation. Microvasc. Res. 49:134-140, 1995.
    • (1995) Microvasc. Res. , vol.49 , pp. 134-140
    • Gretz, J.E.1    Duling, B.R.2
  • 5
    • 0027374735 scopus 로고
    • Imaging system for three-dimensional mapping of cerebrocortical capillary networks in vivo
    • Hudetz, A. G., A. S. Greene, G. Feher, D. E. Knuese, and A. W. J. Cowley. Imaging system for three-dimensional mapping of cerebrocortical capillary networks in vivo. Microvasc. Res. 46:293-309, 1993.
    • (1993) Microvasc. Res. , vol.46 , pp. 293-309
    • Hudetz, A.G.1    Greene, A.S.2    Feher, G.3    Knuese, D.E.4    Cowley, A.W.J.5
  • 7
    • 16044366569 scopus 로고
    • Methods for in vivo mapping and classifying microvascular networks in skeletal muscle
    • edited by A. S. Popel and P. C. Johnson. New York: Karger
    • Koller, A., and P. C. Johnson. Methods for in vivo mapping and classifying microvascular networks in skeletal muscle. In: Microvascular Networks: Experimental and Theoretical Studies, edited by A. S. Popel and P. C. Johnson. New York: Karger, 1986, pp. 27-37.
    • (1986) Microvascular Networks: Experimental and Theoretical Studies , pp. 27-37
    • Koller, A.1    Johnson, P.C.2
  • 8
    • 0024114777 scopus 로고
    • A versatile video image analysis system for microcirculatory research
    • Pries, A. R. A versatile video image analysis system for microcirculatory research. Int. J. Microcirc.: Clin. Exp. 7:327-345, 1988.
    • (1988) Int. J. Microcirc.: Clin. Exp. , vol.7 , pp. 327-345
    • Pries, A.R.1
  • 9
    • 0027089966 scopus 로고
    • Blood viscosity in tube flow: Dependence on diameter and hematocrit
    • Pries, A. R., D. Neuhaus, and P. Gaehtgens. Blood viscosity in tube flow: Dependence on diameter and hematocrit. Am. J. Physiol. 263:H1770-H1778, 1992.
    • (1992) Am. J. Physiol. , vol.263
    • Pries, A.R.1    Neuhaus, D.2    Gaehtgens, P.3
  • 10
    • 85034503630 scopus 로고    scopus 로고
    • Early effects of ionizing radiation on normal tissue microvascular networks
    • in press
    • Roth, N. M., M. R. Sontag, and M. F. Kiani. Early effects of ionizing radiation on normal tissue microvascular networks. Radiat. Res. (in press).
    • Radiat. Res.
    • Roth, N.M.1    Sontag, M.R.2    Kiani, M.F.3
  • 11
    • 23044513947 scopus 로고
    • Electronic measurement of red blood cell velocity and volume flow in microvessels
    • edited by J. Chanyen and L. Bitensky. New York: Marcel Dekker
    • Slaaf, D. W., T. Arts, T. J. M. Jeurens, G. J. Tangelder, and R. S. Reneman. Electronic measurement of red blood cell velocity and volume flow in microvessels. In: Investigative Microtechniques in Medicine and Biology, edited by J. Chanyen and L. Bitensky. New York: Marcel Dekker, 1984, pp. 327-364.
    • (1984) Investigative Microtechniques in Medicine and Biology , pp. 327-364
    • Slaaf, D.W.1    Arts, T.2    Jeurens, T.J.M.3    Tangelder, G.J.4    Reneman, R.S.5
  • 14
    • 0027261078 scopus 로고
    • Evaluation of carbocyanine-labeled erythrocytes for microvascular measurements
    • Unthank, J. L., J. M. Lash, J. C. Nixon, R. A. Sidner, and H. G. Bohlen. Evaluation of carbocyanine-labeled erythrocytes for microvascular measurements. Microvasc. Res. 45:193-210, 1993.
    • (1993) Microvasc. Res. , vol.45 , pp. 193-210
    • Unthank, J.L.1    Lash, J.M.2    Nixon, J.C.3    Sidner, R.A.4    Bohlen, H.G.5
  • 15
    • 0024694382 scopus 로고
    • A microcomputer-based system for mapping microvascular networks
    • Wu, C. H., and P. C. Johnson. A microcomputer-based system for mapping microvascular networks. Int. J. Microcirc.: Clin. Exp. 8:303-311, 1989.
    • (1989) Int. J. Microcirc.: Clin. Exp. , vol.8 , pp. 303-311
    • Wu, C.H.1    Johnson, P.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.