메뉴 건너뛰기




Volumn 28, Issue 1, 1999, Pages 37-41

Predictability of reformatted computed tomography for pre-operative planning of endosseous implants

Author keywords

Dental implant, endosseous; Jaw; Tomography, X ray computed

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; EDENTULOUSNESS; FEMALE; HUMAN; MALE; METHODOLOGY; MIDDLE AGED; PATIENT CARE PLANNING; PREOPERATIVE CARE; REPRODUCIBILITY; TOOTH IMPLANTATION; TREATMENT OUTCOME;

EID: 0032618277     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.dmfr.4600403     Document Type: Article
Times cited : (70)

References (12)
  • 2
    • 0030280461 scopus 로고    scopus 로고
    • Consensus Report Implant therapy II
    • World Workshop in Periodontics. Consensus Report Implant therapy II. Annals Periodontol 1996; 1: 816-820.
    • (1996) Annals Periodontol , vol.1 , pp. 816-820
  • 3
    • 85004987645 scopus 로고
    • Reliability of spiral tomography with the Scanora technique for dental implant planning
    • Ekestubbe A, Gröndahl H-G. Reliability of spiral tomography with the Scanora technique for dental implant planning. Clin Oral Impl Res 1993; 4: 195-202.
    • (1993) Clin Oral Impl Res , vol.4 , pp. 195-202
    • Ekestubbe, A.1    Gröndahl, H.-G.2
  • 4
    • 0024813030 scopus 로고
    • Location of the mandibular canal: Comparison of macroscopic findings, conventional radiography, and computed tomography
    • Klinge B, Petersson A, Maly P. Location of the mandibular canal: Comparison of macroscopic findings, conventional radiography, and computed tomography. Int J Oral Maxillofac Implants 1989; 4: 327-332.
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 327-332
    • Klinge, B.1    Petersson, A.2    Maly, P.3
  • 5
    • 0142140013 scopus 로고
    • Visualisation of the mandibular canal by different radiographic techniques
    • Lindh C, Petersson A, Klinge B. Visualisation of the mandibular canal by different radiographic techniques. Clin Oral Impl Res 1992; 3: 90-97.
    • (1992) Clin Oral Impl Res , vol.3 , pp. 90-97
    • Lindh, C.1    Petersson, A.2    Klinge, B.3
  • 6
    • 0039784995 scopus 로고
    • A comparison of the accuracy of periapical, panoramic and computerized tomographic radiographs in locating the mandibular canal
    • Sonick M, Abrahams J, Faiella RA. A comparison of the accuracy of periapical, panoramic and computerized tomographic radiographs in locating the mandibular canal. Int J Oral Maxillofac Implants 1994; 9: 455-460.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 455-460
    • Sonick, M.1    Abrahams, J.2    Faiella, R.A.3
  • 7
    • 0027726017 scopus 로고
    • Interpretation of linear and computed tomograms in the assessment of implant recipient sites
    • Todd AD, Gher ME, Quintero G, Richardson AC. Interpretation of linear and computed tomograms in the assessment of implant recipient sites. J Periodontol 1993; 64: 1243-1249.
    • (1993) J Periodontol , vol.64 , pp. 1243-1249
    • Todd, A.D.1    Gher, M.E.2    Quintero, G.3    Richardson, A.C.4
  • 8
    • 0028934642 scopus 로고
    • Clinical usefulness of two-dimensional reformatted and three-dimensionally rendered computerized tomographic images: Literature review and a survey of surgeons' opinions
    • Alder ME, Deahl ST, Matteson SR. Clinical usefulness of two-dimensional reformatted and three-dimensionally rendered computerized tomographic images: literature review and a survey of surgeons' opinions. J Oral Maxillofac Surg 1995; 53: 375-386.
    • (1995) J Oral Maxillofac Surg , vol.53 , pp. 375-386
    • Alder, M.E.1    Deahl, S.T.2    Matteson, S.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.