-
1
-
-
0028736007
-
Etalon filters
-
D. M. Rust, “Etalon filters,” Opt. Eng. 33, 3342-3348 (1994).
-
(1994)
Opt. Eng.
, vol.33
, pp. 3342-3348
-
-
Rust, D.M.1
-
2
-
-
85010168997
-
Visible wavelength Doppler lidar for measurement of wind and aerosol profiles during day and night
-
K. F. Fischer, V. J. Abreu, W. R. Skinner, J. E. Barnes, M. J. McGill, and T. D. Irgang, “Visible wavelength Doppler lidar for measurement of wind and aerosol profiles during day and night,” Opt. Eng. 34, 499-511 (1995).
-
(1995)
Opt. Eng.
, vol.34
, pp. 499-511
-
-
Fischer, K.F.1
Abreu, V.J.2
Skinner, W.R.3
Barnes, J.E.4
Mc Gill, M.J.5
Irgang, T.D.6
-
3
-
-
0028749331
-
Incoherent Doppler lidar for measurement of atmospheric winds
-
J. Wang and P. B. Hays, eds., Proc. SPIE 2266
-
W. R. Skinner and P. B. Hays, “Incoherent Doppler lidar for measurement of atmospheric winds,” in Optical Spectroscopic Techniques and Instrumentation for Atmospheric and Space Research, J. Wang and P. B. Hays, eds., Proc. SPIE 2266, 383-394 (1994).
-
(1994)
Optical Spectroscopic Techniques and Instrumentation for Atmospheric and Space Research
, pp. 383-394
-
-
Skinner, W.R.1
Hays, P.B.2
-
4
-
-
0000929250
-
Multiple Fabry-Perot interferometers in an incoherent Doppler lidar
-
M. J. McGill and W. R. Skinner, “Multiple Fabry-Perot interferometers in an incoherent Doppler lidar,” Opt. Eng. 36, 139-145 (1997).
-
(1997)
Opt. Eng.
, vol.36
, pp. 139-145
-
-
Mc Gill, M.J.1
Skinner, W.R.2
-
5
-
-
0019635486
-
A stable, rugged, capacitance-stabilised piezoelectric scanned Fabry-Perot etalon
-
D. Rees, I. McWhirter, P. B. Hays, and T. Dines, “A stable, rugged, capacitance-stabilised piezoelectric scanned Fabry-Perot etalon,” J. Phys. E 14, 1320-1325 (1981).
-
(1981)
J. Phys. E
, vol.14
, pp. 1320-1325
-
-
Rees, D.1
Mc Whirter, I.2
Hays, P.B.3
Dines, T.4
-
6
-
-
0019633024
-
Tunable Fabry-Perot filters
-
P. D. Atherton, N. K. Reay, J. Ring, and T. R. Hicks, “Tunable Fabry-Perot filters,” Opt. Eng. 20, 806-814 (1981).
-
(1981)
Opt. Eng.
, vol.20
, pp. 806-814
-
-
Atherton, P.D.1
Reay, N.K.2
Ring, J.3
Hicks, T.R.4
-
7
-
-
84975586135
-
The PEPSIOS purely interferometric high resolution scanning spectrometer
-
J. E. Mack, D. P. McNutt, F. L. Roesler, and R. Chabbal, “The PEPSIOS purely interferometric high resolution scanning spectrometer,” Appl. Opt. 2, 873-885 (1963).
-
(1963)
Appl. Opt.
, vol.2
, pp. 873-885
-
-
Mack, J.E.1
Mc Nutt, D.P.2
Roesler, F.L.3
Chabbal, R.4
-
8
-
-
0020091449
-
Observations of atmospheric absorption lines from a stabilised balloon platform and measurements of stratospheric winds
-
D. Rees, P. A. Rounce, I. McWhirter, A. F. D. Scott, A. H. Greenaway, and W. Towlson, “Observations of atmospheric absorption lines from a stabilised balloon platform and measurements of stratospheric winds,” J. Phys. E 15, 191-206 (1982).
-
(1982)
J. Phys. E
, vol.15
, pp. 191-206
-
-
Rees, D.1
Rounce, P.A.2
Mc Whirter, I.3
Scott, A.F.D.4
Greenaway, A.H.5
Towlson, W.6
-
9
-
-
84975648079
-
Optimization of a triple etalon interferometer
-
W. R. Skinner, P. B. Hays, and V. J. Abreu, “Optimization of a triple etalon interferometer,” Appl. Opt. 26, 2817-2827 (1987).
-
(1987)
Appl. Opt.
, vol.26
, pp. 2817-2827
-
-
Skinner, W.R.1
Hays, P.B.2
Abreu, V.J.3
-
10
-
-
0010481071
-
The High Resolution Doppler Imager: Instrument performance in orbit since late 1991
-
P. B. Hays and J. Wang, eds., Proc. SPIE 2830
-
W. R. Skinner, P. B. Hays, H. J. Grassl, D. A. Gell, M. D. Burrage, A. R. Marshall, and J. Kafkalidis, “The High Resolution Doppler Imager: instrument performance in orbit since late 1991,” in Optical Spectroscopic Techniques and Instrumentation for Atmospheric and Space Research, P. B. Hays and J. Wang, eds., Proc. SPIE 2830, 202-214 (1996).
-
(1996)
Optical Spectroscopic Techniques and Instrumentation for Atmospheric and Space Research
, pp. 202-214
-
-
Skinner, W.R.1
Hays, P.B.2
Grassl, H.J.3
Gell, D.A.4
Burrage, M.D.5
Marshall, A.R.6
Kafkalidis, J.7
-
12
-
-
84975555770
-
Effects of plate defects in a polyetalon Fabry-Perot spectrometer
-
F. L. Roesler, “Effects of plate defects in a polyetalon Fabry-Perot spectrometer,” Appl. Opt. 8, 829-831 (1969).
-
(1969)
Appl. Opt.
, vol.8
, pp. 829-831
-
-
Roesler, F.L.1
-
13
-
-
84975648481
-
Coating stress in Fabry-Perot etalons
-
P. A. Greet, “Coating stress in Fabry-Perot etalons,” Appl. Opt. 25, 3328-3330 (1986).
-
(1986)
Appl. Opt.
, vol.25
, pp. 3328-3330
-
-
Greet, P.A.1
-
14
-
-
0027653423
-
Measured optical performance of three Fabry-Perot interferometers for use in a tunable ultraviolet filter
-
C. Korendyke and D. G. Socker, “Measured optical performance of three Fabry-Perot interferometers for use in a tunable ultraviolet filter,” Opt. Eng. 32, 2281-2285 (1993).
-
(1993)
Opt. Eng.
, vol.32
, pp. 2281-2285
-
-
Korendyke, C.1
Socker, D.G.2
-
15
-
-
0344527509
-
Recherches expérimentales et théoriques sur la généralisation de lemploi du spectrometre Fabry-Perot aux divers domaines de la spectroscopie
-
R. Chabbal, “Recherches expérimentales et théoriques sur la généralisation de l’emploi du spectrometre Fabry-Perot aux divers domaines de la spectroscopie,” Rev. Opt. 37, 49-104 (1958).
-
(1958)
Rev. Opt.
, vol.37
, pp. 49-104
-
-
Chabbal, R.1
-
16
-
-
0027797282
-
The High-Resolution Doppler Imager on the Upper Atmosphere Research Satellite
-
P. B. Hays, V. J. Abreu, M. E. Dobbs, D. A. Gell, H. J. Grassl, and W. R. Skinner, “The High-Resolution Doppler Imager on the Upper Atmosphere Research Satellite,” J. Geophys. Res. 98, 10,713-10,723 (1993).
-
(1993)
J. Geophys. Res.
, vol.98
, pp. 10713-10723
-
-
Hays, P.B.1
Abreu, V.J.2
Dobbs, M.E.3
Gell, D.A.4
Grassl, H.J.5
Skinner, W.R.6
-
17
-
-
85010184247
-
-
University of Michigan, Ann Arbor, Mich. 481092143 (e-mail communication, 7 December
-
W. Skinner, University of Michigan, Ann Arbor, Mich. 481092143 (e-mail communication, 7 December 1998).
-
(1998)
-
-
Skinner, W.1
|