메뉴 건너뛰기




Volumn 7, Issue 5, 1999, Pages 296-302

Comparison of polylactide screw and expansion bolt in bioabsorbable fixation with patellar tendon bone graft for anterior cruciate ligament rupture of the knee: A preliminary study

Author keywords

Anterior cruciate ligament reconstruction; Bioabsorbable; Expansion plug; Polylactide; Self reinforced poly L lactide screw

Indexed keywords

BIOMATERIAL; POLYESTER; POLYLACTIDE;

EID: 0032606108     PISSN: 09422056     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001670050167     Document Type: Review
Times cited : (18)

References (26)
  • 1
    • 84873788096 scopus 로고
    • Reconstruction of the anterior cruciate ligament: A new technique using the central one-third of the patellar ligament
    • Jones KG (1963) Reconstruction of the anterior cruciate ligament: a new technique using the central one-third of the patellar ligament. J Bone Joint Surg Am 45:925-932
    • (1963) J Bone Joint Surg Am , vol.45 , pp. 925-932
    • Jones, K.G.1
  • 2
    • 0020656022 scopus 로고
    • Vascularized patellar tendon graft with rigid internal fixation for anterior cruciate ligament insufficiency
    • Lambert K (1983) Vascularized patellar tendon graft with rigid internal fixation for anterior cruciate ligament insufficiency. Clin Orthop 172:85-89
    • (1983) Clin Orthop , vol.172 , pp. 85-89
    • Lambert, K.1
  • 3
    • 0028326991 scopus 로고
    • Interference fixation versus postfixation of bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction
    • Paschal SO, Seemann MD, Ashman RB, Allard RN, Montgomery JB (1994) Interference fixation versus postfixation of bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction. Clin Orthop 300: 281-284
    • (1994) Clin Orthop , vol.300 , pp. 281-284
    • Paschal, S.O.1    Seemann, M.D.2    Ashman, R.B.3    Allard, R.N.4    Montgomery, J.B.5
  • 4
    • 0023280269 scopus 로고
    • A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction
    • Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 15: 225-229
    • (1987) Am J Sports Med , vol.15 , pp. 225-229
    • Kurosaka, M.1    Yoshiya, S.2    Andrish, J.T.3
  • 5
    • 0027275217 scopus 로고
    • Biomechanical evaluation of interference screw fixation in a bovine patellar bone-tendon-bone autograft complex for anterior cruciate ligament reconstruction arthroscopy
    • Hulstyn M, Fadale PD, Abate J, Walsh WR (1993) Biomechanical evaluation of interference screw fixation in a bovine patellar bone-tendon-bone autograft complex for anterior cruciate ligament reconstruction arthroscopy. Arthroscopy 9:417-424
    • (1993) Arthroscopy , vol.9 , pp. 417-424
    • Hulstyn, M.1    Fadale, P.D.2    Abate, J.3    Walsh, W.R.4
  • 6
    • 0027508563 scopus 로고
    • The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts
    • Brown CH, Hecker AT, Hipp JA, Myers ER, Hayes WC (1993) The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts. Am J Sports Med 21: 880-886
    • (1993) Am J Sports Med , vol.21 , pp. 880-886
    • Brown, C.H.1    Hecker, A.T.2    Hipp, J.A.3    Myers, E.R.4    Hayes, W.C.5
  • 7
    • 0027518153 scopus 로고
    • Effect of varying angles on the pullout strength of interference screw fixation
    • Jomha NM, Raso VJ, Leung P (1993) Effect of varying angles on the pullout strength of interference screw fixation. Arthroscopy 9:580-583
    • (1993) Arthroscopy , vol.9 , pp. 580-583
    • Jomha, N.M.1    Raso, V.J.2    Leung, P.3
  • 8
    • 0026459258 scopus 로고
    • The biomechanical effects of geometric configuration of bone-tendon-bone autografts in anterior cruciate ligament reconstruction
    • Schapiro JD, Cohn BT, Jackson DW, Postak PD, Parker RD, Greenwald AS (1992) The biomechanical effects of geometric configuration of bone-tendon-bone autografts in anterior cruciate ligament reconstruction. Arthroscopy 8:453-458
    • (1992) Arthroscopy , vol.8 , pp. 453-458
    • Schapiro, J.D.1    Cohn, B.T.2    Jackson, D.W.3    Postak, P.D.4    Parker, R.D.5    Greenwald, A.S.6
  • 9
    • 0029971540 scopus 로고    scopus 로고
    • The relationship between tunnel placement and clinical results after anterior cruciate ligament reconstruction
    • Khalfayan EE, Sharkey PF, Alexander AH, et al. (1996) The relationship between tunnel placement and clinical results after anterior cruciate ligament reconstruction. Am J Sports Med 24: 335-341
    • (1996) Am J Sports Med , vol.24 , pp. 335-341
    • Khalfayan, E.E.1    Sharkey, P.F.2    Alexander, A.H.3
  • 10
    • 0026731925 scopus 로고
    • Tibial tunnel placement in anterior cruciate ligament reconstructions and graft impingement
    • Howell SM, Clark JA (1992) Tibial tunnel placement in anterior cruciate ligament reconstructions and graft impingement. Clin Orthop 283:187-195
    • (1992) Clin Orthop , vol.283 , pp. 187-195
    • Howell, S.M.1    Clark, J.A.2
  • 11
    • 0030026551 scopus 로고    scopus 로고
    • Radiographic evaluation of native anterior cruciate ligament attachments and graft placement for reconstruction
    • Lintner DM, Dewitt SE, Moseley JB (1996) Radiographic evaluation of native anterior cruciate ligament attachments and graft placement for reconstruction. Am J Sports Med 24:72-78
    • (1996) Am J Sports Med , vol.24 , pp. 72-78
    • Lintner, D.M.1    Dewitt, S.E.2    Moseley, J.B.3
  • 12
    • 0028917811 scopus 로고
    • The effects of tibial tunnel placement and roofplasty on reconstructed anterior ligament knees
    • Muneta T, Yamamoto H, Ishibashi T, et al. (1995) The effects of tibial tunnel placement and roofplasty on reconstructed anterior ligament knees. Arthroscopy 11:57-62
    • (1995) Arthroscopy , vol.11 , pp. 57-62
    • Muneta, T.1    Yamamoto, H.2    Ishibashi, T.3
  • 13
    • 0028039953 scopus 로고
    • Anterior cruciate ligament reconstruction with patellar tendon. An ex-vivo study of wear releated damage and failure at the femoral tunnel
    • Graf BK, Henry J, Rothenberg M, Vanderby R (1994) Anterior cruciate ligament reconstruction with patellar tendon. An ex-vivo study of wear releated damage and failure at the femoral tunnel. Am J Sports Med 22: 131-135
    • (1994) Am J Sports Med , vol.22 , pp. 131-135
    • Graf, B.K.1    Henry, J.2    Rothenberg, M.3    Vanderby, R.4
  • 14
    • 0028308770 scopus 로고
    • Bone tunnel enlargement after anterior cruciate ligament replacement
    • Fahey M, Indelicato PA (1994) Bone tunnel enlargement after anterior cruciate ligament replacement. Am J Sports Med 22:410-414
    • (1994) Am J Sports Med , vol.22 , pp. 410-414
    • Fahey, M.1    Indelicato, P.A.2
  • 15
    • 0026063856 scopus 로고
    • Anterior cruciate ligament reconstruction using freeze-dried, ethylene oxide-sterilized bone-patellar tendon-bone allografts
    • Roberts TS, Drez D, McCarthy W, Paine R (1991) Anterior cruciate ligament reconstruction using freeze-dried, ethylene oxide-sterilized bone-patellar tendon-bone allografts. Am J Sports Med 19:35-41
    • (1991) Am J Sports Med , vol.19 , pp. 35-41
    • Roberts, T.S.1    Drez, D.2    McCarthy, W.3    Paine, R.4
  • 16
    • 0021842535 scopus 로고
    • Biodegradable implants in fracture fixation: Early results of fracture treatment of fractures of the ankle
    • Rokkanen P, Böstman O, Vainionpää S, et al. (1985) Biodegradable implants in fracture fixation: early results of fracture treatment of fractures of the ankle. Lancet 1:1422
    • (1985) Lancet , vol.1 , pp. 1422
    • Rokkanen, P.1    Böstman, O.2    Vainionpää, S.3
  • 17
    • 0029986978 scopus 로고    scopus 로고
    • Absorbable devices in the fixation of fractures
    • Rokkanen P, Böstman O, Vainionpää S, et al. (1996) Absorbable devices in the fixation of fractures. J Trauma 40: 123-127
    • (1996) J Trauma , vol.40 , pp. 123-127
    • Rokkanen, P.1    Böstman, O.2    Vainionpää, S.3
  • 21
    • 0028206787 scopus 로고
    • A biodegradable expansion plug for fixation of the coracoid bone block in the Bristow-Latarjet operation
    • Pihlajamäki H, Böstman O, Rokkanen P (1994) A biodegradable expansion plug for fixation of the coracoid bone block in the Bristow-Latarjet operation. Int Orthop 18:66-71
    • (1994) Int Orthop , vol.18 , pp. 66-71
    • Pihlajamäki, H.1    Böstman, O.2    Rokkanen, P.3
  • 23
    • 0028809821 scopus 로고
    • Fixation strength of a biodegradable screw in anterior cruciate ligament reconstruction
    • Järvinen M, Kousa P, Järvinen T, et al. (1994) Fixation strength of a biodegradable screw in anterior cruciate ligament reconstruction. J Bone Joint Surg Br 77:901-905
    • (1994) J Bone Joint Surg Br , vol.77 , pp. 901-905
    • Järvinen, M.1    Kousa, P.2    Järvinen, T.3
  • 24
    • 0029788658 scopus 로고    scopus 로고
    • Strength of the fixation of patellar tendon bone grafts using a totally absorbable self-reinforced poly-L-lactide expansion plug and screw. An experimental study in a bovine cadaver
    • Tuompo P, Partio E K, Jukkala-Partio, K, et al. (1996) Strength of the fixation of patellar tendon bone grafts using a totally absorbable self-reinforced poly-L-lactide expansion plug and screw. An experimental study in a bovine cadaver. J Arthrose Relat Surg 12:422-427
    • (1996) J Arthrose Relat Surg , vol.12 , pp. 422-427
    • Tuompo, P.1    Partio, E.K.2    Jukkala-Partio, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.