메뉴 건너뛰기




Volumn 33, Issue 5, 1999, Pages 259-264

The extended Biocor® stentless aortic bioprosthesis. Early clinical experience

Author keywords

Aortic prostheses; Haemodynamic evaluation; Stentless

Indexed keywords

ADULT; AGED; AORTA PROSTHESIS; AORTA STENOSIS; AORTA VALVE REGURGITATION; ARTICLE; BIOPROSTHESIS; CLINICAL TRIAL; CORONARY ARTERY BYPASS GRAFT; ENDOCARDITIS; FEMALE; FOLLOW UP; HEART HEMODYNAMICS; HUMAN; MAJOR CLINICAL STUDY; MALE; MORTALITY; PERICARDIUM; PRESSURE; PRIORITY JOURNAL; PROSTHESIS FAILURE; THROMBOEMBOLISM; AORTA VALVE; AORTA VALVE STENOSIS; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; MIDDLE AGED; PROSTHESIS; TREATMENT OUTCOME;

EID: 0032589755     PISSN: 14017431     EISSN: None     Source Type: Journal    
DOI: 10.1080/14017439950141498     Document Type: Article
Times cited : (14)

References (19)
  • 1
    • 0025191277 scopus 로고
    • Aortic valve replacement with stentless porcine aortic bioprosthesis
    • David TE, Pollick C, Bos J. Aortic valve replacement with stentless porcine aortic bioprosthesis. J Thorac Cardiovasc Surg 1990; 99: 113-118.
    • (1990) J Thorac Cardiovasc Surg , vol.99 , pp. 113-118
    • David, T.E.1    Pollick, C.2    Bos, J.3
  • 2
    • 0028249804 scopus 로고
    • The O'Brien-Angell stentless valve. Early results of 100 implants
    • Hvass U, Chatel D, Ouroudji M, et al. The O'Brien-Angell stentless valve. Early results of 100 implants. Eur J Cardiothorac Surg 1994; 8: 384-387.
    • (1994) Eur J Cardiothorac Surg , vol.8 , pp. 384-387
    • Hvass, U.1    Chatel, D.2    Ouroudji, M.3
  • 3
    • 0029016342 scopus 로고
    • The Toronto SPV bioprosthesis: One-year results in 100 patients
    • Mohr FW, Walther T, Baryalei M, et al. The Toronto SPV bioprosthesis: one-year results in 100 patients. Ann Thorac Surg 1995; 60: 171-175.
    • (1995) Ann Thorac Surg , vol.60 , pp. 171-175
    • Mohr, F.W.1    Walther, T.2    Baryalei, M.3
  • 6
    • 0026323319 scopus 로고
    • Effect of stent mounting on tissue valves for aortic valve replacement
    • Angell WW, Pupello DF, Bessone LN, Hiro SP, Brock JC. Effect of stent mounting on tissue valves for aortic valve replacement. J Cardiac Surg 1991 ; 6 Suppl 4: 595-599.
    • (1991) J Cardiac Surg , vol.6 , Issue.SUPPL. 4 , pp. 595-599
    • Angell, W.W.1    Pupello, D.F.2    Bessone, L.N.3    Hiro, S.P.4    Brock, J.C.5
  • 7
    • 0028673425 scopus 로고
    • Porcine stentless aortic heart valve substitute: Mid term clinical follow-up
    • Vrandecic M, Gontijo BF, Fantini FA, et al. Porcine stentless aortic heart valve substitute: mid term clinical follow-up. J Cardiovasc Surg 1994; 35 Suppl 1: 31-34.
    • (1994) J Cardiovasc Surg , vol.35 , Issue.SUPPL. 1 , pp. 31-34
    • Vrandecic, M.1    Gontijo, B.F.2    Fantini, F.A.3
  • 8
    • 0022355265 scopus 로고
    • Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography
    • Skjaerpe T, Hegrenaes L, Hatle L. Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography. Circulation 1985; 72: 810-818.
    • (1985) Circulation , vol.72 , pp. 810-818
    • Skjaerpe, T.1    Hegrenaes, L.2    Hatle, L.3
  • 10
    • 0024723470 scopus 로고
    • Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American society of echocardiography committee on standards
    • Schiller NB, Shah PM, Crawford M, et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of echocardiography committee on standards. J Am Soc Echocardiogr 1989; 2: 358-367.
    • (1989) J Am Soc Echocardiogr , vol.2 , pp. 358-367
    • Schiller, N.B.1    Shah, P.M.2    Crawford, M.3
  • 13
    • 0029093740 scopus 로고
    • Perioperative assessment of aortic homograft, Toronto stentless valve, and stented valve in the aortic position
    • Jin XY, Gibson DG, Yacoub MH, Pepper JR. Perioperative assessment of aortic homograft, Toronto stentless valve, and stented valve in the aortic position. Ann Thorac Surg 1995; 60: S395-401.
    • (1995) Ann Thorac Surg , vol.60
    • Jin, X.Y.1    Gibson, D.G.2    Yacoub, M.H.3    Pepper, J.R.4
  • 14
    • 0029080237 scopus 로고
    • Aortic valve replacement with a stentless porcine bioprosthesis: Multicentre trial
    • Del Rizzo DF, Goldman BS, David TE. Aortic valve replacement with a stentless porcine bioprosthesis: multicentre trial. Can J Cardiol 1995; 11: 597-603.
    • (1995) Can J Cardiol , vol.11 , pp. 597-603
    • Del Rizzo, D.F.1    Goldman, B.S.2    David, T.E.3
  • 17
    • 0027102191 scopus 로고
    • Aortic valve replacement in octogenarians with aortic stenosis: A case control study
    • Olsson M, Granström L, Lindblom D, Rosenqvist M, Rydén L. Aortic valve replacement in octogenarians with aortic stenosis: a case control study. J Am Coll Cardiol 1992; 20: 1512-1516.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1512-1516
    • Olsson, M.1    Granström, L.2    Lindblom, D.3    Rosenqvist, M.4    Rydén, L.5
  • 19
    • 0027652695 scopus 로고
    • Risk analysis of low cardiac output syndrome after valve replacement
    • Sato N, Uchida N, Miura M, et al. Risk analysis of low cardiac output syndrome after valve replacement. Tohoku J Exp Med 1993; 171: 77-88.
    • (1993) Tohoku J Exp Med , vol.171 , pp. 77-88
    • Sato, N.1    Uchida, N.2    Miura, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.