-
2
-
-
0023761196
-
Mitral annulus motion: Relation to pulmonary venous and transmitral flows in normal subjects and in patients with dilated cardiomydpathy
-
Karen G., Sonnenblick E.H. and Le Jemetel T.H. Mitral annulus motion: Relation to pulmonary venous and transmitral flows in normal subjects and in patients with dilated cardiomydpathy. Circulation 1988; 78: 621-629
-
(1988)
Circulation
, vol.78
, pp. 621-629
-
-
Karen, G.1
Sonnenblick, E.H.2
Le Jemetel, T.H.3
-
3
-
-
0026197022
-
Doppler assesment of pulmonary venous flow in healthy patients and in patients with heart disease
-
Klein A.L. and Tajik A.J. Doppler assesment of pulmonary venous flow in healthy patients and in patients with heart disease. J. Amer. Soc Echocardiogr. 1991; 4: 379-392.
-
(1991)
J. Amer. Soc Echocardiogr.
, vol.4
, pp. 379-392
-
-
Klein, A.L.1
Tajik, A.J.2
-
4
-
-
0025141328
-
Pulmonary flow determined by Doppler echocardiography in mitral stenosis
-
Karen G , Pandes A., Miller H.I., Scherez J. and Lanicado S. Pulmonary flow determined by Doppler echocardiography in mitral stenosis. Amer J. Cardiol. 1990; 65: 246-249.
-
(1990)
Amer J. Cardiol.
, vol.65
, pp. 246-249
-
-
Karen, G.1
Pandes, A.2
Miller, H.I.3
Scherez, J.4
Lanicado, S.5
-
5
-
-
0026247969
-
Pulmonary venous flow velocity: Relation to haemodynamics, mitral flow velocity and left atrial volume and ejection fraction
-
Basnight M.A., Gonzalez M.S., Kershenovich S.C. and Appleton C.P. Pulmonary venous flow velocity: relation to haemodynamics, mitral flow velocity and left atrial volume and ejection fraction J. Amer. Soc. Echocardiogr. 1991; 4: 547-558.
-
(1991)
J. Amer. Soc. Echocardiogr.
, vol.4
, pp. 547-558
-
-
Basnight, M.A.1
Gonzalez, M.S.2
Kershenovich, S.C.3
Appleton, C.P.4
-
6
-
-
0000685295
-
Percutaneous baloon mitral valvoplasty Vs. open mitral commissurotomy: Results of a randomised clinical trial
-
Bueno R., Andrade P., Nercolini D., Loures D., Ribeiro E., Blume L., Rossi P., Pereira M., Chama M. and Curitiba P. Percutaneous baloon mitral valvoplasty Vs. open mitral commissurotomy: results of a randomised clinical trial. JACC 1993; 21: 429A-434A.
-
(1993)
JACC
, vol.21
-
-
Bueno, R.1
Andrade, P.2
Nercolini, D.3
Loures, D.4
Ribeiro, E.5
Blume, L.6
Rossi, P.7
Pereira, M.8
Chama, M.9
Curitiba, P.10
-
7
-
-
0029157685
-
Mitral dilation with the multi - Track system: An alternative approach
-
Bonhoeffer P., Piechaud J.F., Sidi D., Yonga G., Jowi C. and Joshi M. et al Mitral dilation with the multi - track system: an alternative approach. Cathet. Cardiovas Diagn. 1995; 36: 189-193.
-
(1995)
Cathet. Cardiovas Diagn.
, vol.36
, pp. 189-193
-
-
Bonhoeffer, P.1
Piechaud, J.F.2
Sidi, D.3
Yonga, G.4
Jowi, C.5
Joshi, M.6
-
8
-
-
85047676225
-
Pulsatile flow in pulmonary artery, capillary and vein in the dog
-
Guntheroth W.G., Gould R., Butler J. and Kinen E. Pulsatile flow in pulmonary artery, capillary and vein in the dog. Cardiovasc Res 1974; 8: 330-337
-
(1974)
Cardiovasc Res
, vol.8
, pp. 330-337
-
-
Guntheroth, W.G.1
Gould, R.2
Butler, J.3
Kinen, E.4
-
9
-
-
0025950505
-
Atrial contribution to left ventricular filling in mitral stenosis
-
Meisner J.S., Keren G., Pajaro O., Mani A., Stron J.A. and Frater R.W.M. Atrial contribution to left ventricular filling in mitral stenosis. Circulation 1991; 84:1469-1480.
-
(1991)
Circulation
, vol.84
, pp. 1469-1480
-
-
Meisner, J.S.1
Keren, G.2
Pajaro, O.3
Mani, A.4
Stron, J.A.5
Frater, R.W.M.6
-
10
-
-
0025239151
-
Relation of pulmonary vein to mitral flow velocities by trans - Oesophageal Doppler echocardiography. Effect of different loading conditions
-
Nishimura R.A., Abel M.D., Hatle L.K. and Tajik A.J. Relation of pulmonary vein to mitral flow velocities by trans - oesophageal Doppler echocardiography. Effect of different loading conditions. Circulation 1990; 81: 1488-1497
-
(1990)
Circulation
, vol.81
, pp. 1488-1497
-
-
Nishimura, R.A.1
Abel, M.D.2
Hatle, L.K.3
Tajik, A.J.4
-
11
-
-
0023753489
-
Inaccuracy of pressure half- time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance
-
Thomas J.D., Wilkins G.T., Choong C.Y.P., Abascal V.M., Palacious I.F., Block P.C. and Weyman A.E. Inaccuracy of pressure half- time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance. Circulation 1988; 78: 980-993
-
(1988)
Circulation
, vol.78
, pp. 980-993
-
-
Thomas, J.D.1
Wilkins, G.T.2
Choong, C.Y.P.3
Abascal, V.M.4
Palacious, I.F.5
Block, P.C.6
Weyman, A.E.7
-
12
-
-
0025943403
-
Left ventricular volumes and function immediately after baloon mitral valvoplasty
-
Mohan J.C., Nair M. and Arora R. Left ventricular volumes and function immediately after baloon mitral valvoplasty. Int. J Cardiol. 1991; 33:275-280.
-
(1991)
Int. J Cardiol.
, vol.33
, pp. 275-280
-
-
Mohan, J.C.1
Nair, M.2
Arora, R.3
-
13
-
-
0026079982
-
Effects of percutaneous baloon mitral valvoplasty on left ventricular mass and volume
-
Tischler M.D., St John Sutton M., Bittl J.A. and Parker J.D. Effects of percutaneous baloon mitral valvoplasty on left ventricular mass and volume. Amer. J Cardiol 1991; 68:940-944.
-
(1991)
Amer. J Cardiol
, vol.68
, pp. 940-944
-
-
Tischler, M.D.1
St John Sutton, M.2
Bittl, J.A.3
Parker, J.D.4
|