메뉴 건너뛰기




Volumn 48, Issue 8, 1999, Pages 533-537

Pre-analytic errors in the determination of arterial O 2-partial pressure under hyperoxic conditions;Praanalytische fehlerquellen bei der bestimmung des arteriellen sauerstoffpartialdrucks unter hyperoxischen bedingungen

Author keywords

Arterial blood gas analysis; Pre analytic errors

Indexed keywords

GLASS; OXYGEN; PLASTIC;

EID: 0032587542     PISSN: 00032417     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001010050744     Document Type: Article
Times cited : (4)

References (11)
  • 1
    • 0000751185 scopus 로고
    • Variation in arterial blood gas measurement due to sampling techniques
    • Bageant RA (1975) Variation in arterial blood gas measurement due to sampling techniques. Respir Care 20:565-570
    • (1975) Respir Care , vol.20 , pp. 565-570
    • Bageant, R.A.1
  • 2
    • 0020060661 scopus 로고
    • Blood gas analysis: Effect of air bubbles in syringe and delay in estimation
    • Biswas CK, Ramos JM, Agroyannis B, Kerr DNS (1982) Blood gas analysis: effect of air bubbles in syringe and delay in estimation. Br Med J 284:923-927
    • (1982) Br Med J , vol.284 , pp. 923-927
    • Biswas, C.K.1    Ramos, J.M.2    Agroyannis, B.3    Kerr, D.N.S.4
  • 4
    • 0014667584 scopus 로고
    • Von den Werten der Blutgase und des pH zur gezielten Therapie
    • Germano GH, Brennan K (1969) Von den Werten der Blutgase und des pH zur gezielten Therapie. Med Welt 20:295-299
    • (1969) Med Welt , vol.20 , pp. 295-299
    • Germano, G.H.1    Brennan, K.2
  • 5
    • 0023720868 scopus 로고
    • Importance of correct handling of samples for their results of blood gas analysis
    • Harsten A, Berg B, Inerot S, Muth L (1988) Importance of correct handling of samples for their results of blood gas analysis. Acta Anaesthesiol Scand 32:365-368
    • (1988) Acta Anaesthesiol Scand , vol.32 , pp. 365-368
    • Harsten, A.1    Berg, B.2    Inerot, S.3    Muth, L.4
  • 6
    • 0016209744 scopus 로고
    • The effects of air bubbles and time delay on blood gas analysis
    • Ishikawa S, Fornier A, Borst C, Segal MS (1974) The effects of air bubbles and time delay on blood gas analysis. Ann Allergy 33:72-77
    • (1974) Ann Allergy , vol.33 , pp. 72-77
    • Ishikawa, S.1    Fornier, A.2    Borst, C.3    Segal, M.S.4
  • 7
    • 0002292095 scopus 로고
    • 2 partial pressure
    • Zander R, Mertzlufft F (eds) Karger, Basel München Paris
    • 2 partial pressure. In: Zander R, Mertzlufft F (eds) The Oxygen Status of Arterial Blood. Karger, Basel München Paris, pp 44-51
    • (1988) The Oxygen Status of Arterial Blood , pp. 44-51
    • Kimmich, H.P.1
  • 8
    • 0002689150 scopus 로고
    • Measurement of blood oxygen tension in anesthesia
    • Laver MB, Seifen A (1965) Measurement of blood oxygen tension in anesthesia. Anesthesiology 26:73-101
    • (1965) Anesthesiology , vol.26 , pp. 73-101
    • Laver, M.B.1    Seifen, A.2
  • 9
    • 0018976645 scopus 로고
    • Air bubbles and temperature effect on blood gas analysis
    • Madiedo G, Sciacca R, Hause L (1980) Air bubbles and temperature effect on blood gas analysis. J Clin Pathol 33:864-867
    • (1980) J Clin Pathol , vol.33 , pp. 864-867
    • Madiedo, G.1    Sciacca, R.2    Hause, L.3
  • 10
    • 16744368055 scopus 로고
    • Maßnahmen zur Qualitätsverbesserung von Blutgasanalysen
    • Müller-Plathe O (1981) Maßnahmen zur Qualitätsverbesserung von Blutgasanalysen. Med Lab 7/8:177-183
    • (1981) Med Lab , vol.7-8 , pp. 177-183
    • Müller-Plathe, O.1
  • 11
    • 0016500677 scopus 로고
    • Plastic or glass syringes: A comparison of the changes in oxygen tension when blood or water samples are stored in iced water
    • Restall RVF, Miller SE, Hahn C, Epstein H (1975) Plastic or glass syringes: a comparison of the changes in oxygen tension when blood or water samples are stored in iced water. Br J Anaesth 47:636-637
    • (1975) Br J Anaesth , vol.47 , pp. 636-637
    • Restall, R.V.F.1    Miller, S.E.2    Hahn, C.3    Epstein, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.