메뉴 건너뛰기




Volumn 50, Issue 2, 1999, Pages 301-303

What is disinfection, sterilization? [1]

Author keywords

[No Author keywords available]

Indexed keywords

BACTERIAL GROWTH; BACTERIUM CONTAMINATION; DISINFECTION; ENDOSCOPE; FOOD AND DRUG ADMINISTRATION; INSTRUMENT STERILIZATION; LETTER; PRACTICE GUIDELINE; PRIORITY JOURNAL; ATYPICAL MYCOBACTERIOSIS; BACTERIAL COUNT; CROSS INFECTION; DISEASE TRANSMISSION; DRUG EFFECT; HUMAN; METHODOLOGY; MYCOBACTERIUM CHELONEI; NOTE; RECYCLING; TUBERCULOSIS;

EID: 0032586880     PISSN: 00165107     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0016-5107(99)70250-6     Document Type: Letter
Times cited : (3)

References (14)
  • 2
    • 0031900104 scopus 로고    scopus 로고
    • Soaking endoscopes in 2% glutaraldehyde for 20 minutes: a risk management perspective
    • LF Muscarella Soaking endoscopes in 2% glutaraldehyde for 20 minutes: a risk management perspective Am J Infect Control 26 1998 153 155
    • (1998) Am J Infect Control , vol.26 , pp. 153-155
    • Muscarella, LF1
  • 3
    • 3543067807 scopus 로고    scopus 로고
    • Guidance on the content and format of premarket 510(k) submissions for liquid chemical germicides
    • The Food and Drug Administration Guidance on the content and format of premarket 510(k) submissions for liquid chemical germicides 1995, 1997 FDA
    • (1997)
    • The Food and Drug Administration1
  • 4
    • 0029283682 scopus 로고
    • FDA labeling requirements for disinfection of endoscopes: a counterpoint
    • WA Rutala DJ Weber FDA labeling requirements for disinfection of endoscopes: a counterpoint Infect Control Hosp Epidemiol 16 1995 231 235
    • (1995) Infect Control Hosp Epidemiol , vol.16 , pp. 231-235
    • Rutala, WA1    Weber, DJ2
  • 5
    • 85119798180 scopus 로고    scopus 로고
    • Cidex activated dialdehyde solution (2.4% glutaraldehyde). Label insert. Johnson and Johnson Medical, Inc, Arlington, Texas.
  • 6
    • 0031861889 scopus 로고    scopus 로고
    • Risk of contamination of sterile biopsy forceps in disinfected endoscopes
    • RM Lee RA Kozarek S Sumida S Raltz Risk of contamination of sterile biopsy forceps in disinfected endoscopes Gastrointest Endosc 47 1998 377 381
    • (1998) Gastrointest Endosc , vol.47 , pp. 377-381
    • Lee, RM1    Kozarek, RA2    Sumida, S3    Raltz, S4
  • 7
    • 0023135296 scopus 로고
    • Use of membrane filters for measurement of mycobactericidal activity of alkaline glutaraldehyde solution
    • FM Collins Use of membrane filters for measurement of mycobactericidal activity of alkaline glutaraldehyde solution Appl Environ Microbiol 53 1987 737 739
    • (1987) Appl Environ Microbiol , vol.53 , pp. 737-739
    • Collins, FM1
  • 8
    • 0023404984 scopus 로고
    • A more accurate method for measurement of tuberculocidal activity of disinfectants
    • J Ascenzi RJ Ezzell TM Wendt A more accurate method for measurement of tuberculocidal activity of disinfectants Appl Environ Microbiol 53 1987 2189 2192
    • (1987) Appl Environ Microbiol , vol.53 , pp. 2189-2192
    • Ascenzi, J1    Ezzell, RJ2    Wendt, TM3
  • 9
    • 85119807895 scopus 로고
    • Cidex Plus 28 day solution: a new stabilized alkaline glutaraldehyde disinfecting and sterilizing solution
    • NI Bruckner Cidex Plus 28 day solution: a new stabilized alkaline glutaraldehyde disinfecting and sterilizing solution 1986 Research Division, Johnson and Johnson Medical, Inc, Arlington, Texas
    • (1986)
    • Bruckner, NI1
  • 10
    • 0344778690 scopus 로고
    • Important information concerning the reuse of glutaraldehyde-based disinfectants and their tuberculocidal activity
    • JM Ascenzi TM Wendt JW McDowell Important information concerning the reuse of glutaraldehyde-based disinfectants and their tuberculocidal activity 1984 Research Division, Johnson and Johnson Medical, Inc, Arlington, Texas
    • (1984)
    • Ascenzi, JM1    Wendt, TM2    McDowell, JW3
  • 11
    • 85119806378 scopus 로고    scopus 로고
    • Procide NS, Procide, Procide plus: 510(k) summary of safety and efficacy. Cottrell Ltd, Englewood, Colorado.
  • 12
    • 0028857656 scopus 로고
    • Disinfection and sterilization strategies and the potential for airborne transmission of bloodborne pathogens: microbiologic considerations
    • MS Favero EA Bolyard Disinfection and sterilization strategies and the potential for airborne transmission of bloodborne pathogens: microbiologic considerations Surg Clin North Am 75 1995 1071 1089
    • (1995) Surg Clin North Am , vol.75 , pp. 1071-1089
    • Favero, MS1    Bolyard, EA2
  • 13
    • 0030074574 scopus 로고    scopus 로고
    • Low-temperature sterilization technologies: do we need to redefine “sterilization”?
    • WA Rutala DJ Weber Low-temperature sterilization technologies: do we need to redefine “sterilization”? Infect Control Hosp Epidemiol 17 1996 87 91
    • (1996) Infect Control Hosp Epidemiol , vol.17 , pp. 87-91
    • Rutala, WA1    Weber, DJ2
  • 14
    • 0032064010 scopus 로고    scopus 로고
    • Are all sterilization processes alike?
    • LF Muscarella Are all sterilization processes alike? AORN J 67 1998 966 976
    • (1998) AORN J , vol.67 , pp. 966-976
    • Muscarella, LF1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.