메뉴 건너뛰기




Volumn 86, Issue 1, 1998, Pages 55-61

Measuring eye position with the double magnetic induction method

Author keywords

Double magnetic induction; Eye movement recording

Indexed keywords

ARTICLE; DEVICE; EYE POSITION; MAGNETISM; MEASUREMENT; NONHUMAN; PERFORMANCE; PRIORITY JOURNAL; TECHNIQUE;

EID: 0032585586     PISSN: 01650270     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0165-0270(98)00145-9     Document Type: Article
Times cited : (12)

References (9)
  • 1
    • 0019861090 scopus 로고
    • Control and sense of eye movement behind closed eye lids
    • Allik J, Rauk M, Luuk A Control and sense of eye movement behind closed eye lids. Perception. 10:1981;39-51.
    • (1981) Perception , vol.10 , pp. 39-51
    • Allik, J.1    Rauk, M.2    Luuk, A.3
  • 2
    • 0016717106 scopus 로고
    • The main sequence: A tool for studying eye movements
    • Bahill AT, Clark MR, Stark L The main sequence: A tool for studying eye movements. Math Biosci. 24:1975;191-204.
    • (1975) Math Biosci , vol.24 , pp. 191-204
    • Bahill, A.T.1    Clark, M.R.2    Stark, L.3
  • 3
    • 0021286407 scopus 로고
    • The double magnetic induction method for measuring eye movement - Results in monkey and man
    • Bour LJ, van Gisbergen JAM, Bruijns J, Ottes FP The double magnetic induction method for measuring eye movement - Results in monkey and man. IEEE Trans Biomed Eng. BME-31:1984;419-427.
    • (1984) IEEE Trans Biomed Eng , vol.31 , pp. 419-427
    • Bour, L.J.1    Van Gisbergen, J.A.M.2    Bruijns, J.3    Ottes, F.P.4
  • 4
    • 0019190225 scopus 로고
    • Implantation of magnetic search coils for measurement of eye position: An improved method
    • Judge SJ, Richmond BJ, Chu FC Implantation of magnetic search coils for measurement of eye position: An improved method. Vis Res. 20:1980;535-538.
    • (1980) Vis Res , vol.20 , pp. 535-538
    • Judge, S.J.1    Richmond, B.J.2    Chu, F.C.3
  • 5
    • 0026687165 scopus 로고
    • A new method of mounting and directing chronically implanted microdrives
    • Malpeli JG, Weyand T, LaClair R A new method of mounting and directing chronically implanted microdrives. J Neurosci Methods. 44:1992;19-26.
    • (1992) J Neurosci Methods , vol.44 , pp. 19-26
    • Malpeli, J.G.1    Weyand, T.2    Laclair, R.3
  • 6
    • 0021286209 scopus 로고
    • An inexpensive eye movement monitor using a scleral search coil technique
    • Remmel RS An inexpensive eye movement monitor using a scleral search coil technique. IEEE Trans Biomed Eng. BME-31:1984;388-390.
    • (1984) IEEE Trans Biomed Eng , vol.31 , pp. 388-390
    • Remmel, R.S.1
  • 7
    • 0020330210 scopus 로고
    • The measurement of eye movement using double magnetic induction
    • Reulen JPH, Bakker L The measurement of eye movement using double magnetic induction. IEEE Trans Biomed Eng. BME-29:1982;740-744.
    • (1982) IEEE Trans Biomed Eng , vol.29 , pp. 740-744
    • Reulen, J.P.H.1    Bakker, L.2
  • 8
    • 0344806451 scopus 로고
    • A method of measuring eye movement using a scleral search coil in a magnetic field
    • Robinson DA A method of measuring eye movement using a scleral search coil in a magnetic field. IEEE Trans Biomed Eng. BME-10:1963;137-145.
    • (1963) IEEE Trans Biomed Eng , vol.10 , pp. 137-145
    • Robinson, D.A.1
  • 9
    • 0031795956 scopus 로고    scopus 로고
    • Effects of focal inactivation of dorsal or ventral layers of the lateral geniculate nucleus on cats' ability to see and fixate small targets
    • Tate AK, Malpeli JG. Effects of focal inactivation of dorsal or ventral layers of the lateral geniculate nucleus on cats' ability to see and fixate small targets. J Neurophysiol, 1998;80:2206-9.
    • (1998) J Neurophysiol , vol.80 , pp. 2206-2209
    • Tate, A.K.1    Malpeli, J.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.