메뉴 건너뛰기




Volumn 359, Issue 1-2, 1998, Pages 157-171

Modeling and optimization studies for a sequential flow based bio- analytical system

Author keywords

Axial dispersion plug flow model; Blood chemistry analyzer; Flow injection analysis; Glucose; Sequential injection

Indexed keywords

GLUCOSE;

EID: 0032546048     PISSN: 00032670     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-2670(97)00577-1     Document Type: Article
Times cited : (6)

References (21)
  • 1
    • 0016687208 scopus 로고
    • Flow injection analysis. Part I. A new concept of fast continuous flow analysis
    • Ruzicka J., Hansen E.H. Flow injection analysis. Part I. A new concept of fast continuous flow analysis. Anal. Chim. Acta. 78:1975;145-157.
    • (1975) Anal. Chim. Acta , vol.78 , pp. 145-157
    • Ruzicka, J.1    Hansen, E.H.2
  • 2
    • 0025168899 scopus 로고
    • Sequential injection: A new concept for chemical sensors, process analysis and laboratory assays
    • Ruzicka J., Marshall G.D. Sequential injection: A new concept for chemical sensors, process analysis and laboratory assays. Anal. Chim. Acta. 237:1990;329-343.
    • (1990) Anal. Chim. Acta , vol.237 , pp. 329-343
    • Ruzicka, J.1    Marshall, G.D.2
  • 3
    • 0001492960 scopus 로고
    • Influence of the main parameters of single line flow injection systems without chemical reaction on the output signal, Part 1: Dispersion characteristics of the main sections of the flow system
    • Kolev S.D., Pungor E. Influence of the main parameters of single line flow injection systems without chemical reaction on the output signal, Part 1: Dispersion characteristics of the main sections of the flow system. Anal. Chim. Acta. 208:1988;117-132.
    • (1988) Anal. Chim. Acta , vol.208 , pp. 117-132
    • Kolev, S.D.1    Pungor, E.2
  • 4
    • 0001492961 scopus 로고
    • Influence of the main parameters of single line flow injection systems without chemical reaction on the output signal, Part 2: Simulation of the mathematical models
    • Kolev S.D., Pungor E. Influence of the main parameters of single line flow injection systems without chemical reaction on the output signal, Part 2: Simulation of the mathematical models. Anal. Chim. Acta. 208:1988;133-149.
    • (1988) Anal. Chim. Acta , vol.208 , pp. 133-149
    • Kolev, S.D.1    Pungor, E.2
  • 6
    • 0027180825 scopus 로고
    • Mathematical model for flow injection analysis: First order chemical reaction in a straight tube
    • Andreev V.P., Khidekel M.I. Mathematical model for flow injection analysis: First order chemical reaction in a straight tube. Anal. Chim. Acta. 278:1993;307-316.
    • (1993) Anal. Chim. Acta , vol.278 , pp. 307-316
    • Andreev, V.P.1    Khidekel, M.I.2
  • 9
    • 0002429729 scopus 로고
    • Kinetics in continuous flow sample processing - C hemical contributions to dispersion in flow injection techniques
    • Painton C.C., Mottola H.A. Kinetics in continuous flow sample processing - chemical contributions to dispersion in flow injection techniques. Anal. Chim. Acta. 158:1984;67-84.
    • (1984) Anal. Chim. Acta , vol.158 , pp. 67-84
    • Painton, C.C.1    Mottola, H.A.2
  • 10
    • 0022537616 scopus 로고
    • Sample dispersion with chemical reaction in a flow injection system
    • Wada H., Hiraoka S., Yuchi A., Nakagawa G. Sample dispersion with chemical reaction in a flow injection system. Anal. Chim. Acta. 179:1986;181-188.
    • (1986) Anal. Chim. Acta , vol.179 , pp. 181-188
    • Wada, H.1    Hiraoka, S.2    Yuchi, A.3    Nakagawa, G.4
  • 18
    • 0026111229 scopus 로고
    • Control and optimization of apheresis procedures in a COBE 2997 cell separator
    • Wooten S.L., Petersen J.N., Van Wie B.J. Control and optimization of apheresis procedures in a COBE 2997 cell separator. J. Biomech. Eng. 113:1991;11-20.
    • (1991) J. Biomech. Eng. , vol.113 , pp. 11-20
    • Wooten, S.L.1    Petersen, J.N.2    Van Wie, B.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.