메뉴 건너뛰기




Volumn 41, Issue 5, 1998, Pages 1185-1192

In vivo neutron dosimetry during high-energy bremsstrahlung radiotherapy

Author keywords

High energy medical accelerators; In vivo dosimetry; In phantom dosimetry; Photoneutrons; Superheated drop detectors

Indexed keywords

ARTICLE; BREMS RADIATION; DOSE RESPONSE; DOSIMETRY; IMAGE QUALITY; NEUTRON DOSIMETRY; PRIORITY JOURNAL; RELIABILITY;

EID: 0032528223     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(98)00162-X     Document Type: Article
Times cited : (38)

References (21)
  • 3
    • 0001470989 scopus 로고
    • The superheated drop detector
    • Apfel R.E. The superheated drop detector. Nucl. Instrum. Methods. 162:1979;603-608.
    • (1979) Nucl. Instrum. Methods , vol.162 , pp. 603-608
    • Apfel, R.E.1
  • 4
    • 0001604809 scopus 로고
    • Photoneutron leakage from medical accelerators: A comprehensive approach to patient and personnel dose measurement
    • ISBN 1-55048-657-8, Montreal: IRPA;
    • d'Errico, F.; Curzio, G. Photoneutron leakage from medical accelerators: A comprehensive approach to patient and personnel dose measurement. In: Proc. IRPA8. ISBN 1-55048-657-8, Vol. I, Montreal: IRPA; 1992:833-836.
    • (1992) In: Proc. IRPA8 , vol.1 , pp. 833-836
    • D'Errico, F.1    Curzio, G.2
  • 5
    • 0027286239 scopus 로고
    • Superheated drop detector for determination of neutron dose equivalent to patients undergoing high energy x-ray and electron radiotherapy
    • Nath R., Meigooni A.S., King R., Smolen S., d'Errico F. Superheated drop detector for determination of neutron dose equivalent to patients undergoing high energy x-ray and electron radiotherapy. Med. Phys. 20:1993;781-787.
    • (1993) Med. Phys. , vol.20 , pp. 781-787
    • Nath, R.1    Meigooni, A.S.2    King, R.3    Smolen, S.4    D'Errico, F.5
  • 6
    • 85092678529 scopus 로고    scopus 로고
    • In-phantom dosimetry and spectrometry of photoneutrons from an 18 MV linear accelerator
    • (accepted)
    • d'Errico, F.; Nath, R.; Tana, L.; Curzio, G.; Alberts, W. G. In-phantom dosimetry and spectrometry of photoneutrons from an 18 MV linear accelerator. Med. Phys. (accepted).
    • Med. Phys.
    • D'Errico, F.1    Nath, R.2    Tana, L.3    Curzio, G.4    Alberts, W.G.5
  • 7
    • 0030889566 scopus 로고    scopus 로고
    • Advances in superheated drop (bubble) detector techniques
    • d'Errico F., Alberts W.G., Matzke M. Advances in superheated drop (bubble) detector techniques. Radiat. Prot. Dosim. 70:1997;103-108.
    • (1997) Radiat. Prot. Dosim. , vol.70 , pp. 103-108
    • D'Errico, F.1    Alberts, W.G.2    Matzke, M.3
  • 8
    • 0000899868 scopus 로고
    • PTB neutron fields for the calibration of neutron sensitive devices
    • W. Kölzer, & R. Maushart. Rheinland, Köln: Verlag TÜV
    • Guldbakke S., Dietz E., Kluge H., Schlegel D. PTB neutron fields for the calibration of neutron sensitive devices. Kölzer W., Maushart R. Strahlenschutz Physik und Messtechnik . 1994;240-247 Verlag TÜV, Rheinland, Köln.
    • (1994) Strahlenschutz: Physik und Messtechnik , pp. 240-247
    • Guldbakke, S.1    Dietz, E.2    Kluge, H.3    Schlegel, D.4
  • 10
    • 0345709889 scopus 로고    scopus 로고
    • Monte Carlo evaluation of the detection efficiency of a superheated drop detector
    • Gualdrini, G. F.; d'Errico, F.; Noccioni, P. Monte Carlo evaluation of the detection efficiency of a superheated drop detector. ENEA Report RT/AMB/97/1 (1997).
    • (1997) ENEA Report RT/AMB/97/1
    • Gualdrini, G.F.1    D'Errico, F.2    Noccioni, P.3
  • 11
    • 0010481171 scopus 로고
    • Calculations of quality factors for fast neutrons in materials composed of H, C, N, and O
    • EUR-8395 Luxembourg: Commission of the European Communities;
    • Siebert, B. R. L.; Caswell, R. S.; Coyne, J. J. Calculations of quality factors for fast neutrons in materials composed of H, C, N, and O. In: Proc. 8th Symp. on Microdosimetry, EUR-8395 Luxembourg: Commission of the European Communities; 1982.
    • (1982) In: Proc. 8th Symp. on Microdosimetry
    • Siebert, B.R.L.1    Caswell, R.S.2    Coyne, J.J.3
  • 12
    • 0018933433 scopus 로고
    • Kerma factors for neutrons energies below 30 MeV
    • Caswell R.S., Coyne J.J., Randolph M.L. Kerma factors for neutrons energies below 30 MeV. Radiat. Res. 83:1980;217-254.
    • (1980) Radiat. Res. , vol.83 , pp. 217-254
    • Caswell, R.S.1    Coyne, J.J.2    Randolph, M.L.3
  • 15
    • 0021266808 scopus 로고
    • Neutrons from high-energy x-ray medical accelerators: An estimate of risk to the radiotherapy patient
    • Nath R., Epp E.R., Laughlin J.S., Swanson W.P., Bond V.P. Neutrons from high-energy x-ray medical accelerators An estimate of risk to the radiotherapy patient . Med. Phys. 11:1984;231-241.
    • (1984) Med. Phys. , vol.11 , pp. 231-241
    • Nath, R.1    Epp, E.R.2    Laughlin, J.S.3    Swanson, W.P.4    Bond, V.P.5
  • 18
    • 0019449771 scopus 로고
    • Measurement and calculation of ovary and fetus dose in extended field radiotherapy for 10 MV x-rays
    • Sharma S.C., Williamson J., Khan F.M., Lee C.C.K. Measurement and calculation of ovary and fetus dose in extended field radiotherapy for 10 MV x-rays. Int. J. Radiat. Oncol. Biol. Phys. 7:1981;843-846.
    • (1981) Int. J. Radiat. Oncol. Biol. Phys. , vol.7 , pp. 843-846
    • Sharma, S.C.1    Williamson, J.2    Khan, F.M.3    Lee, C.C.K.4
  • 20
    • 0026441128 scopus 로고
    • Recent patterns of growth in radiation therapy facilities in the United States: A Patterns of Care study report
    • Owen J.B., Coia L.R., Hanks G.E. Recent patterns of growth in radiation therapy facilities in the United States A Patterns of Care study report . Int. J. Oncol. Biol. Phys. 24:1992;983-986.
    • (1992) Int. J. Oncol. Biol. Phys. , vol.24 , pp. 983-986
    • Owen, J.B.1    Coia, L.R.2    Hanks, G.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.