메뉴 건너뛰기




Volumn 89, Issue 2, 1998, Pages 53-58

Biotinylated platelets have an impaired response to agonists as evidenced by in vitro platelet aggregation tests

Author keywords

Biotin; Blood platelets; Platelet aggregation

Indexed keywords

BIOTIN DERIVATIVE; ENDOTHELIAL LEUKOCYTE ADHESION MOLECULE 1;

EID: 0032518214     PISSN: 00493848     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0049-3848(97)00290-9     Document Type: Article
Times cited : (14)

References (10)
  • 2
    • 0027531056 scopus 로고
    • Investigation of human platelet alloantigens and glycoproteins using non-radioactive immunoprecipitation
    • Smith J.W., Hayward C.P.M., Warkentin T.E., Horsewood P., Kelton J.G. Investigation of human platelet alloantigens and glycoproteins using non-radioactive immunoprecipitation. J Immun Methods. 158:1993;77-85.
    • (1993) J Immun Methods , vol.158 , pp. 77-85
    • Smith, J.W.1    Hayward, C.P.M.2    Warkentin, T.E.3    Horsewood, P.4    Kelton, J.G.5
  • 3
    • 0028849399 scopus 로고
    • Antibodies against GPIb/IX, GPIIb/IIIa and other platelet antigens in chronic immune thrombocytopenic purpura
    • Hou M., Stockelberg D., Kutti J., Wadenvik H. Antibodies against GPIb/IX, GPIIb/IIIa and other platelet antigens in chronic immune thrombocytopenic purpura. Eur J Haematol. 55:1995;307-314.
    • (1995) Eur J Haematol , vol.55 , pp. 307-314
    • Hou, M.1    Stockelberg, D.2    Kutti, J.3    Wadenvik, H.4
  • 5
    • 26544478064 scopus 로고
    • Biotinylation: A non-radioisotopic platelet label
    • Hawker R.J., Ahmadian M., Nicholson G.S. Biotinylation. a non-radioisotopic platelet label Transfusion. Supplement 32):1992;76S.
    • (1992) Transfusion , vol.32
    • Hawker, R.J.1    Ahmadian, M.2    Nicholson, G.S.3
  • 6
    • 0029127976 scopus 로고
    • In vivo biotinylation demonstrates that reticulated platelets are the youngest platelets in circulation
    • Ault K.A., Knowles C. In vivo biotinylation demonstrates that reticulated platelets are the youngest platelets in circulation. Exper Hematol. 23:1995;996-1001.
    • (1995) Exper Hematol , vol.23 , pp. 996-1001
    • Ault, K.A.1    Knowles, C.2
  • 7
    • 0027957299 scopus 로고
    • Aged platelets have an impaired response to thrombin as quantitated by P-Selectin expression
    • Peng J.P., Friese P., Heilmann E., George J.N., Burstein S.A., Dale G.L. Aged platelets have an impaired response to thrombin as quantitated by P-Selectin expression. Blood. 83:1994;161-166.
    • (1994) Blood , vol.83 , pp. 161-166
    • Peng, J.P.1    Friese, P.2    Heilmann, E.3    George, J.N.4    Burstein, S.A.5    Dale, G.L.6
  • 8
    • 0028122548 scopus 로고
    • Use of bi-level biotinylation for concurrent measurement of in vivo recovery and survival in two rabbit platelet population
    • Franco R.S., Lee K.N., Barker-Gear R., Gatse R., Menitove J.E. Use of bi-level biotinylation for concurrent measurement of in vivo recovery and survival in two rabbit platelet population. Transfusion. 34:1994;784-789.
    • (1994) Transfusion , vol.34 , pp. 784-789
    • Franco, R.S.1    Lee, K.N.2    Barker-Gear, R.3    Gatse, R.4    Menitove, J.E.5
  • 9
    • 0019461764 scopus 로고
    • Indium-111-labelled human platelets: Improved method, efficacy, and evaluation
    • Thakur M.L., Walsh L., Malech H.L., Gottschalk A. Indium-111-labelled human platelets. improved method, efficacy, and evaluation J Nuclear Med. 22:1981;381-385.
    • (1981) J Nuclear Med , vol.22 , pp. 381-385
    • Thakur, M.L.1    Walsh, L.2    Malech, H.L.3    Gottschalk, A.4
  • 10
    • 0024409949 scopus 로고
    • Correlated measurement of platelet release and aggregation in whole blood
    • Ault K.A., Rinder H.M., Mitchell C.S., Lambrew C.T., Hillman R.S. Correlated measurement of platelet release and aggregation in whole blood. Cytometry. 10:1989;448-455.
    • (1989) Cytometry , vol.10 , pp. 448-455
    • Ault, K.A.1    Rinder, H.M.2    Mitchell, C.S.3    Lambrew, C.T.4    Hillman, R.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.