메뉴 건너뛰기




Volumn 33, Issue 9, 1998, Pages 488-495

Determinants of image appearance in contrast-enhanced magnetic resonance angiography: A review

Author keywords

[No Author keywords available]

Indexed keywords

CONTRAST ENHANCEMENT; DIGITAL SUBTRACTION ANGIOGRAPHY; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; IMAGING SYSTEM; MAGNETIC RESONANCE ANGIOGRAPHY; PRIORITY JOURNAL; REVIEW;

EID: 0032470384     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-199809000-00003     Document Type: Review
Times cited : (35)

References (15)
  • 5
    • 0030770299 scopus 로고    scopus 로고
    • Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: Application to the renal arteries
    • Wilman A, Riederer S, King B, Debbins J, Rossman P, Ehman R. Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: Application to the renal arteries. Radiology 1997;205:135-146.
    • (1997) Radiology , vol.205 , pp. 135-146
    • Wilman, A.1    Riederer, S.2    King, B.3    Debbins, J.4    Rossman, P.5    Ehman, R.6
  • 6
    • 0031906175 scopus 로고    scopus 로고
    • Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography
    • Kim J, Farb R, Wright G. Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography. Radiology 1998;206:283-289.
    • (1998) Radiology , vol.206 , pp. 283-289
    • Kim, J.1    Farb, R.2    Wright, G.3
  • 7
    • 0029805810 scopus 로고    scopus 로고
    • Breathhold single dose gadolinium enhanced 3D MR aortography: Utility of a test bolus and MR power injector
    • Earls J, Rofsky N, Decoroto D, Krinsky G, Weinreb J. Breathhold single dose gadolinium enhanced 3D MR aortography: Utility of a test bolus and MR power injector. Radiology 1996;201:705-710.
    • (1996) Radiology , vol.201 , pp. 705-710
    • Earls, J.1    Rofsky, N.2    Decoroto, D.3    Krinsky, G.4    Weinreb, J.5
  • 8
    • 0030893848 scopus 로고    scopus 로고
    • An automated method for detecting the bolus arrival time and initiating data acquisition in fast 3D gadolinium-enhanced MRA
    • Foo T, Marojkumar S, Prince M, Chenevert T. An automated method for detecting the bolus arrival time and initiating data acquisition in fast 3D gadolinium-enhanced MRA. Radiology 1997;203:275-280.
    • (1997) Radiology , vol.203 , pp. 275-280
    • Foo, T.1    Marojkumar, S.2    Prince, M.3    Chenevert, T.4
  • 10
    • 0028509723 scopus 로고
    • Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography
    • Du YP, Parker DL, Davis WL, Cao G. Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography. J Magn Reson Imaging 1994;4(5):733-741.
    • (1994) J Magn Reson Imaging , vol.4 , Issue.5 , pp. 733-741
    • Du, Y.P.1    Parker, D.L.2    Davis, W.L.3    Cao, G.4
  • 11
    • 0029966835 scopus 로고    scopus 로고
    • Image subtraction in gadolinium-enhanced MR imaging
    • Lee V, Flyer M, Krinsky G, Rofsky N. Image subtraction in gadolinium-enhanced MR imaging. Am J Roentgenol 1996;167:1427-1432.
    • (1996) Am J Roentgenol , vol.167 , pp. 1427-1432
    • Lee, V.1    Flyer, M.2    Krinsky, G.3    Rofsky, N.4
  • 13
    • 0028845732 scopus 로고
    • Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches
    • Prince M, Narasimham D, Stanley J, et al. Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. Radiology 1995;197:785-792.
    • (1995) Radiology , vol.197 , pp. 785-792
    • Prince, M.1    Narasimham, D.2    Stanley, J.3
  • 15
    • 0030183445 scopus 로고    scopus 로고
    • The effects of time varying intravascular signal intensity and k-space acquisition order on three dimensional MR angiography image quality
    • Maki J, Prince M, Londy F, Chenevert T. The effects of time varying intravascular signal intensity and k-space acquisition order on three dimensional MR angiography image quality. J Magn Reson Imaging 1996;6:642-651.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 642-651
    • Maki, J.1    Prince, M.2    Londy, F.3    Chenevert, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.