Volumn 14, Issue 7-8, 1998, Pages 485-489

The fast flush test - Is the clinical comparison eouivalent to its in vitro simulation?

Author keywords

Blood pressure; Dynamic response; Fast flush test; Natural frequency, damping

Indexed keywords

BLOOD VESSELS; CARDIOVASCULAR SYSTEM; DAMPING; DYNAMIC RESPONSE; MANOMETERS; NATURAL FREQUENCIES; PRESSURE MEASUREMENT; PULSATILE FLOW;

EID: 0032462511     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1009987329163     Document Type: Article
Times cited : (4)

References (8)
  • 1
    • 0019523842 scopus 로고
    • Direct blood pressure measurement - Dynamic response requirements
    • Gardner RM. Direct blood pressure measurement - dynamic response requirements. Anesthesiology 1981; 54: 227-236
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 2
    • 0344391833 scopus 로고
    • Physiologic recording by modern instruments with particular reference to pressure recording
    • Fry DL. Physiologic recording by modern instruments with particular reference to pressure recording. Physiol Rev 1960; 40: 753-788
    • (1960) Physiol Rev , vol.40 , pp. 753-788
    • Fry, D.L.1
  • 3
    • 0030110761 scopus 로고    scopus 로고
    • Equivalence of fast flush and square wave testing of blood pressure monitoring systems
    • Kleinman B, Powell S, Gardner RM. Equivalence of fast flush and square wave testing of blood pressure monitoring systems. J Clin Monit 1996; 12: 149-154
    • (1996) J Clin Monit , vol.12 , pp. 149-154
    • Kleinman, B.1    Powell, S.2    Gardner, R.M.3
  • 4
    • 0026690056 scopus 로고
    • The fast flush test measures the dynamic response of the entire blood pressure monitoring system
    • Kleinman B, Powell S, Kumar P, Gardner RM. The fast flush test measures the dynamic response of the entire blood pressure monitoring system. Anesthesiology 1992; 77: 1215-1220
    • (1992) Anesthesiology , vol.77 , pp. 1215-1220
    • Kleinman, B.1    Powell, S.2    Kumar, P.3    Gardner, R.M.4
  • 7
    • 0024544132 scopus 로고
    • Understanding natural frequency and damping and how they relate to the measurement of blood pressure
    • Kleinman B. Understanding natural frequency and damping and how they relate to the measurement of blood pressure. J Clin Monit 1989; 5: 137-147
    • (1989) J Clin Monit , vol.5 , pp. 137-147
    • Kleinman, B.1
  • 8
    • 0023786403 scopus 로고
    • Frequency response evaluation of radial artery catheter-manometer systems: Sinusoidal frequency analysis versus flush method
    • Schwid HA. Frequency response evaluation of radial artery catheter-manometer systems: Sinusoidal frequency analysis versus flush method. J Clin Monit 1988; 4: 181-185
    • (1988) J Clin Monit , vol.4 , pp. 181-185
    • Schwid, H.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.