메뉴 건너뛰기




Volumn 29, Issue 11, 1998, Pages 684-687

Noninvasive and invasive sensors for patient monitoring

Author keywords

[No Author keywords available]

Indexed keywords

BIOSENSOR; ELECTROCHEMISTRY; ELECTRODE; FIBER OPTICS; HUMAN; PATIENT MONITORING; PULSE OXIMETER; REVIEW; SENSOR;

EID: 0032461227     PISSN: 00075027     EISSN: None     Source Type: Journal    
DOI: 10.1093/labmed/29.11.684     Document Type: Review
Times cited : (6)

References (11)
  • 2
    • 0025050669 scopus 로고
    • Current analytical approaches to measuring blood analytes
    • Burritt MF. Current analytical approaches to measuring blood analytes. Clin Chem. 1990;36:1562-1566.
    • (1990) Clin Chem. , vol.36 , pp. 1562-1566
    • Burritt, M.F.1
  • 3
    • 0029665546 scopus 로고    scopus 로고
    • 2 as an accurate predictor of therapy in limb salvage
    • 2 as an accurate predictor of therapy in limb salvage. Ann Vasc Surg. 1996;10:224-227.
    • (1996) Ann Vasc Surg. , vol.10 , pp. 224-227
    • Bunt, T.J.1    Holloway, G.A.2
  • 4
    • 0031029378 scopus 로고    scopus 로고
    • Transcutaneous bilirubinometry: Its role in the assessment of neonatal jaundice
    • Dai J, Parry DM, Krahn J. Transcutaneous bilirubinometry: its role in the assessment of neonatal jaundice. Clin Biochem. 1997;30:1-9.
    • (1997) Clin Biochem. , vol.30 , pp. 1-9
    • Dai, J.1    Parry, D.M.2    Krahn, J.3
  • 5
    • 0029052094 scopus 로고
    • Pulse oximetry in ventilated preterm newborns: Reliability of detection of hyperoxaemia and hypoxaemia, and feasibility of alarm settings
    • Paky F, Koeck CM. Pulse oximetry in ventilated preterm newborns: reliability of detection of hyperoxaemia and hypoxaemia, and feasibility of alarm settings. Acta Paediatr. 1995;84:613-616.
    • (1995) Acta Paediatr. , vol.84 , pp. 613-616
    • Paky, F.1    Koeck, C.M.2
  • 6
    • 0031036953 scopus 로고    scopus 로고
    • Noninvasive blood glucose monitoring
    • Klonoff DC. Noninvasive blood glucose monitoring. Diabetes Care. 1997;20:433-437.
    • (1997) Diabetes Care. , vol.20 , pp. 433-437
    • Klonoff, D.C.1
  • 7
    • 0025108769 scopus 로고
    • Continuous ex vivo and in vivo monitoring with chemical sensors
    • Fogt E. Continuous ex vivo and in vivo monitoring with chemical sensors. Clin Chem. 1990;36:1573-1580.
    • (1990) Clin Chem. , vol.36 , pp. 1573-1580
    • Fogt, E.1
  • 8
    • 0027420041 scopus 로고
    • Clinical performance of a blood gas monitor: A prospective, multicenter trial
    • Shapiro BA, Mahutte CK, Cane RD, et al. Clinical performance of a blood gas monitor: a prospective, multicenter trial. Crit Care Med. 1993;21:487-494.
    • (1993) Crit Care Med. , vol.21 , pp. 487-494
    • Shapiro, B.A.1    Mahutte, C.K.2    Cane, R.D.3
  • 9
    • 0028265076 scopus 로고
    • Continuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: A prospective, criterion standard study
    • Haller M, Kilger E, Briegel J, et al. Continuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: a prospective, criterion standard study. Crit Care Med. 1994;22:580-587.
    • (1994) Crit Care Med. , vol.22 , pp. 580-587
    • Haller, M.1    Kilger, E.2    Briegel, J.3
  • 10
    • 0029886585 scopus 로고    scopus 로고
    • Clinical evaluation of a multiparameter intra-arterial blood-gas sensor
    • Abraham E, Gallagher TJ, Fink S. Clinical evaluation of a multiparameter intra-arterial blood-gas sensor. Intensive Care Med. 1996;22:507-513.
    • (1996) Intensive Care Med. , vol.22 , pp. 507-513
    • Abraham, E.1    Gallagher, T.J.2    Fink, S.3
  • 11
    • 0025181253 scopus 로고
    • Intravascular monitoring: Problems and promise
    • Halbert SA. Intravascular monitoring: problems and promise. Clin Chem. 1990;36:1581-1584.
    • (1990) Clin Chem. , vol.36 , pp. 1581-1584
    • Halbert, S.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.