메뉴 건너뛰기




Volumn 8, Issue 2, 1998, Pages 91-110

Contact stress at articular surfaces in total joint replacements. Part I: Experimental methods

Author keywords

Contact stress; Joint replacements; Photoelasticity; Pressure sensitive film; Resistive ink sensor

Indexed keywords

BIOMATERIAL; EPOXIDE; POLITEF; POLYVINYLIDENE FLUORIDE; PROTECTIVE AGENT;

EID: 0032457616     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (68)
  • 3
    • 0029027099 scopus 로고
    • Effect of polyethylene quality on wear in total knee arthroplasty
    • M.G. Tanner, L.A. Whiteside and S.E. White, Effect of polyethylene quality on wear in total knee arthroplasty, Clin. Orthop. Rel. Res. 317 (1995), 83-88.
    • (1995) Clin. Orthop. Rel. Res. , vol.317 , pp. 83-88
    • Tanner, M.G.1    Whiteside, L.A.2    White, S.E.3
  • 4
    • 0025834740 scopus 로고
    • Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy
    • P. Kumar, M. Oka and K. Ikeuchi, Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy, J. Biomed. Mater. Res. 25 (1991), 813-828.
    • (1991) J. Biomed. Mater. Res. , vol.25 , pp. 813-828
    • Kumar, P.1    Oka, M.2    Ikeuchi, K.3
  • 6
    • 0028384735 scopus 로고
    • Optimization of the bearing surface geometry of total knees
    • S. Sathasivam and P.S. Walker, Optimization of the bearing surface geometry of total knees, J. Biomech. 27 (1994), 255-264.
    • (1994) J. Biomech. , vol.27 , pp. 255-264
    • Sathasivam, S.1    Walker, P.S.2
  • 7
    • 0029253653 scopus 로고
    • The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses
    • P.S.M. Barbour, D.C. Barton and J. Fisher, The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses, Wear 181-183(1) (1995), 250-257.
    • (1995) Wear , vol.181-183 , Issue.1 , pp. 250-257
    • Barbour, P.S.M.1    Barton, D.C.2    Fisher, J.3
  • 9
    • 2442769884 scopus 로고    scopus 로고
    • Clinical aspects
    • T.M. Wright and S.B. Goodman, eds, American Academy of Orthopaedic Surgeons, Rosemont, IL
    • Anon, Clinical aspects, in: Implant Wear: The Future of Total Joint Replacement, T.M. Wright and S.B. Goodman, eds, American Academy of Orthopaedic Surgeons, Rosemont, IL, 1996, pp. 1-27.
    • (1996) Implant Wear: The Future of Total Joint Replacement , pp. 1-27
  • 12
    • 0028798063 scopus 로고
    • The problem is osteolysis
    • W.H. Harris, The problem is osteolysis, Clin. Orthop. Rel. Res. 311 (1995), 46-53.
    • (1995) Clin. Orthop. Rel. Res. , vol.311 , pp. 46-53
    • Harris, W.H.1
  • 13
    • 0019256214 scopus 로고
    • The contact area and pressure distribution of the knee
    • F. Fukabayashi and H. Kurosawa, The contact area and pressure distribution of the knee, Acta Orthop. Scand. 51 (1980), 871-879.
    • (1980) Acta Orthop. Scand. , vol.51 , pp. 871-879
    • Fukabayashi, F.1    Kurosawa, H.2
  • 14
    • 0030248396 scopus 로고    scopus 로고
    • Appropriateness of plane pressure-sensitive film calibration for contact stress measurements in articular joints
    • E.M. Hasler, W. Herzog and H.G. Fick, Appropriateness of plane pressure-sensitive film calibration for contact stress measurements in articular joints, Clin. Biomech. 11 (1996), 358-360.
    • (1996) Clin. Biomech. , vol.11 , pp. 358-360
    • Hasler, E.M.1    Herzog, W.2    Fick, H.G.3
  • 17
    • 0028533947 scopus 로고
    • Sterilization of Fuji pressure-sensitive film
    • A.B. Liggins, W.R. Hardie and J.B. Finlay, Sterilization of Fuji pressure-sensitive film, Med. Eng. Phys. 16 (1994), 496-500.
    • (1994) Med. Eng. Phys. , vol.16 , pp. 496-500
    • Liggins, A.B.1    Hardie, W.R.2    Finlay, J.B.3
  • 18
    • 0026911047 scopus 로고
    • Contact stress gradient limits of Pressensor film
    • J.E. Hale and T.D. Brown, Contact stress gradient limits of Pressensor film, J. Biomech. Eng. 114 (1992), 352-357.
    • (1992) J. Biomech. Eng. , vol.114 , pp. 352-357
    • Hale, J.E.1    Brown, T.D.2
  • 21
    • 0027642032 scopus 로고
    • An algorithm for approximate crinkle artifact compensation in pressure-sensitive film recordings
    • N.J. Caldwell, J.E. Hale, M.J. Rudert and T.D. Brown, An algorithm for approximate crinkle artifact compensation in pressure-sensitive film recordings, J. Biomech. 26 (1993), 1001-1009.
    • (1993) J. Biomech. , vol.26 , pp. 1001-1009
    • Caldwell, N.J.1    Hale, J.E.2    Rudert, M.J.3    Brown, T.D.4
  • 22
    • 0023822132 scopus 로고
    • Wear and contact stress studies of the Minns meniscal knee prosthesis
    • K.J. Minns, Wear and contact stress studies of the Minns meniscal knee prosthesis, Eng. Med. 17 (1988), 135-138.
    • (1988) Eng. Med. , vol.17 , pp. 135-138
    • Minns, K.J.1
  • 24
    • 0028009147 scopus 로고
    • A comparison of contact pressures in tibial and patellar total knee components before and after service in vivo
    • J.L. McNamara, J.P. Collier, M.B. Mayor and R.E. Jensen, A comparison of contact pressures in tibial and patellar total knee components before and after service in vivo, Clin. Orthop. Rel. Res. 299 (1994), 104-113.
    • (1994) Clin. Orthop. Rel. Res. , vol.299 , pp. 104-113
    • McNamara, J.L.1    Collier, J.P.2    Mayor, M.B.3    Jensen, R.E.4
  • 27
    • 0029013290 scopus 로고
    • Patellofemoral contact pressures exceed the compressive yield strength of UHMWPE in total knee arthroplasties
    • T. Takeuchi, V.K. Lathi, A.M. Khan and W.C. Hayes, Patellofemoral contact pressures exceed the compressive yield strength of UHMWPE in total knee arthroplasties, J. Arthroplasty 10 (1995), 363-368.
    • (1995) J. Arthroplasty , vol.10 , pp. 363-368
    • Takeuchi, T.1    Lathi, V.K.2    Khan, A.M.3    Hayes, W.C.4
  • 29
    • 0029079875 scopus 로고
    • Tibiofemoral contact stress and stress distribution of total knee arthroplasties
    • J.A. Szivek, A.M. Cutignola and R.G. Volz, Tibiofemoral contact stress and stress distribution of total knee arthroplasties, J. Arthroplasty 10 (1995), 480-491.
    • (1995) J. Arthroplasty , vol.10 , pp. 480-491
    • Szivek, J.A.1    Cutignola, A.M.2    Volz, R.G.3
  • 31
    • 0030111308 scopus 로고    scopus 로고
    • Non-uniformity of contact stress on polyethylene inserts in total knee arthroplasty
    • R.E. Bristol, D.C. Fitzpatrick, T.D. Brown and J.J. Callaghan, Non-uniformity of contact stress on polyethylene inserts in total knee arthroplasty, Clin. Biomech. 11 (1996), 75-80.
    • (1996) Clin. Biomech. , vol.11 , pp. 75-80
    • Bristol, R.E.1    Fitzpatrick, D.C.2    Brown, T.D.3    Callaghan, J.J.4
  • 34
    • 0030457410 scopus 로고    scopus 로고
    • Average and peak contact stress distribution evaluation of total knee arthroplasties
    • J.A. Szivek, P.L. Anderson and J.B. Benjamin, Average and peak contact stress distribution evaluation of total knee arthroplasties, J. Arthroplasty 11 (1996), 952-963.
    • (1996) J. Arthroplasty , vol.11 , pp. 952-963
    • Szivek, J.A.1    Anderson, P.L.2    Benjamin, J.B.3
  • 35
    • 0031080827 scopus 로고    scopus 로고
    • Statically equivalent load and support conditions provide different hip joint contact pressures
    • B.K. Bay, A.J. Hamel, S.A. Olson and N.A. Sharkey, Statically equivalent load and support conditions provide different hip joint contact pressures, J. Biomech. 30 (1997), 193-196.
    • (1997) J. Biomech. , vol.30 , pp. 193-196
    • Bay, B.K.1    Hamel, A.J.2    Olson, S.A.3    Sharkey, N.A.4
  • 36
    • 0030808905 scopus 로고    scopus 로고
    • Patellofemoral joint kinematics and contact pressures in total knee arthroplasty
    • T.Q. Lee, A.P. Gerken, F.E. Glaser, W.C. Kim and S.A. Anzel, Patellofemoral joint kinematics and contact pressures in total knee arthroplasty, Clin. Orthop. Rel. Res. 340 (1997), 257-266.
    • (1997) Clin. Orthop. Rel. Res. , vol.340 , pp. 257-266
    • Lee, T.Q.1    Gerken, A.P.2    Glaser, F.E.3    Kim, W.C.4    Anzel, S.A.5
  • 37
    • 0031105747 scopus 로고    scopus 로고
    • Comparison of predicted and measured contact pressures in normal and dysplastic hips
    • D.A. Michaeli, S.B. Murphy and J.A. Hipp, Comparison of predicted and measured contact pressures in normal and dysplastic hips, Med. Eng. Phys. 19 (1997), 180-186.
    • (1997) Med. Eng. Phys. , vol.19 , pp. 180-186
    • Michaeli, D.A.1    Murphy, S.B.2    Hipp, J.A.3
  • 43
    • 0030826332 scopus 로고    scopus 로고
    • Patellofemoral joint after total knee arthroplasty: Effect on contact area and contact stress
    • S. Matsuda, T. Ishinishi, S.E. White and L.A. Whiteside, Patellofemoral joint after total knee arthroplasty: effect on contact area and contact stress, J. Arthroplasty 12 (1997), 790-797.
    • (1997) J. Arthroplasty , vol.12 , pp. 790-797
    • Matsuda, S.1    Ishinishi, T.2    White, S.E.3    Whiteside, L.A.4
  • 44
    • 0020802378 scopus 로고
    • In vitro measurement of static pressure distribution in synovial joints. Part I: Tibial surface of the knee
    • A.M. Ahmed and D.L. Burke, In vitro measurement of static pressure distribution in synovial joints. Part I: Tibial surface of the knee, Trans. ASME J. Biomech. Eng. 216 (1983), 216-225.
    • (1983) Trans. ASME J. Biomech. Eng. , vol.216 , pp. 216-225
    • Ahmed, A.M.1    Burke, D.L.2
  • 45
    • 0026883590 scopus 로고
    • A miniature piezoelectric polymer transducer for in vitro measurement of the dynamic contact stress distribution
    • M. Manouel, H.S. Pearlman, A. Belakhlef and T.D. Brown, A miniature piezoelectric polymer transducer for in vitro measurement of the dynamic contact stress distribution, J. Biomech. 25 (1992), 627-635.
    • (1992) J. Biomech. , vol.25 , pp. 627-635
    • Manouel, M.1    Pearlman, H.S.2    Belakhlef, A.3    Brown, T.D.4
  • 46
    • 0027748484 scopus 로고
    • Some problems in using a polyvinylidene fluoride transducer for the intra-articular determination of joint contact stress
    • J.E. Hale and C.L. Vaughan, Some problems in using a polyvinylidene fluoride transducer for the intra-articular determination of joint contact stress, Eng. Med. 207 (1993), 127-130.
    • (1993) Eng. Med. , vol.207 , pp. 127-130
    • Hale, J.E.1    Vaughan, C.L.2
  • 48
    • 0014832186 scopus 로고
    • Photoelastic-fringe multiplication: For tenfold increase in sensitivity
    • D. Post, Photoelastic-fringe multiplication: for tenfold increase in sensitivity, Exp. Mech. 10 (1970), 305-312.
    • (1970) Exp. Mech. , vol.10 , pp. 305-312
    • Post, D.1
  • 49
    • 0015279622 scopus 로고
    • On the accuracy of goniometric compensation methods in photoelastic fringe-order mechanisms
    • S.M. Sathikh and G.W. Bigg, On the accuracy of goniometric compensation methods in photoelastic fringe-order mechanisms, Exp. Mech. 12 (1972), 47-49.
    • (1972) Exp. Mech. , vol.12 , pp. 47-49
    • Sathikh, S.M.1    Bigg, G.W.2
  • 50
    • 3643077058 scopus 로고
    • La photoelasticimetrie et ses applications dans la construction aeronautique
    • V. Tesar, La photoelasticimetrie et ses applications dans la construction aeronautique, Sci. Aerien. II (1935), 373-394.
    • (1935) Sci. Aerien. , vol.2 , pp. 373-394
    • Tesar, V.1
  • 51
    • 0003712199 scopus 로고
    • Wiley, New York
    • M.M. Frocht, Photoelasticity, Vols 1 and 2, Wiley, New York, 1941 and 1948.
    • (1941) Photoelasticity , vol.1-2
    • Frocht, M.M.1
  • 52
    • 84981656877 scopus 로고
    • The determination of principal stresses from photoelastic data
    • S.J. Haake and E.A. Patterson, The determination of principal stresses from photoelastic data, Strain 28 (1992), 153-158.
    • (1992) Strain , vol.28 , pp. 153-158
    • Haake, S.J.1    Patterson, E.A.2
  • 53
    • 0022660628 scopus 로고
    • New separation method of photoelastic principal stresses using a micro-computer
    • T. Shibuya, T. Koizumi, K. Takakuda and T. Maeno, New separation method of photoelastic principal stresses using a micro-computer, Bull. JSME 29 (1986), 400-407.
    • (1986) Bull. JSME , vol.29 , pp. 400-407
    • Shibuya, T.1    Koizumi, T.2    Takakuda, K.3    Maeno, T.4
  • 54
    • 0042332552 scopus 로고
    • The method of oblique incidence in photoelasticity
    • D.C. Drucker, The method of oblique incidence in photoelasticity, Proc. Soc. Exp. Stress Anal. VII(1) (1950), 51-56.
    • (1950) Proc. Soc. Exp. Stress Anal. , vol.7 , Issue.1 , pp. 51-56
    • Drucker, D.C.1
  • 55
    • 0014882294 scopus 로고
    • A new separation method of principal stresses for plane stress problems
    • S. Ito and Y. Murakami, A new separation method of principal stresses for plane stress problems, Bull. JSME 13 (1970), 1287-1293.
    • (1970) Bull. JSME , vol.13 , pp. 1287-1293
    • Ito, S.1    Murakami, Y.2
  • 56
    • 0020846485 scopus 로고
    • Least squares asymptotic analysis of photoelastic data from stress concentration regions in plane problems
    • J.C. Thompson and K.J. Negus, Least squares asymptotic analysis of photoelastic data from stress concentration regions in plane problems, Strain 19 (1983), 179-184.
    • (1983) Strain , vol.19 , pp. 179-184
    • Thompson, J.C.1    Negus, K.J.2
  • 57
    • 0024891701 scopus 로고
    • A method for measuring pressures instantaneously in articular joints
    • H. Inaba and M. Arai, A method for measuring pressures instantaneously in articular joints, J. Biomech. 22 (1989), 1293-1297.
    • (1989) J. Biomech. , vol.22 , pp. 1293-1297
    • Inaba, H.1    Arai, M.2
  • 58
    • 0027543629 scopus 로고
    • A new cheap pressure foil
    • R. Bourgois and J. Bel, A new cheap pressure foil, Strain 29 (1993), 27-28.
    • (1993) Strain , vol.29 , pp. 27-28
    • Bourgois, R.1    Bel, J.2
  • 59
    • 0026261060 scopus 로고
    • The use of photoelastic coatings to investigate the pelvic strain variation resulting from the introduction of cementless metal backed acetabular cups
    • D. Slemon, P. O'Donnell and E.G. Little, The use of photoelastic coatings to investigate the pelvic strain variation resulting from the introduction of cementless metal backed acetabular cups, Strain 27 (1991), 143-153.
    • (1991) Strain , vol.27 , pp. 143-153
    • Slemon, D.1    O'Donnell, P.2    Little, E.G.3
  • 60
    • 0025266706 scopus 로고
    • Effect of press-fit femoral stem on strain in the femur. A photoelastic coating study
    • X.M. Zhou, P.S. Walker and D.D. Robertson, Effect of press-fit femoral stem on strain in the femur. A photoelastic coating study, J. Arthroplasty 1 (1990), 71-82.
    • (1990) J. Arthroplasty , vol.1 , pp. 71-82
    • Zhou, X.M.1    Walker, P.S.2    Robertson, D.D.3
  • 61
    • 2442728840 scopus 로고
    • An introduction to thermoelastic analysis
    • N. Harwood and W.M. Cummings, eds, Adam Hilger, Bristol
    • N. Harwood, W.M. Cummings and A. K. MacKenzie, An introduction to thermoelastic analysis, in: Thermoelastic Stress Analysis, N. Harwood and W.M. Cummings, eds, Adam Hilger, Bristol, 1991, pp. 1-34.
    • (1991) Thermoelastic Stress Analysis , pp. 1-34
    • Harwood, N.1    Cummings, W.M.2    MacKenzie, A.K.3
  • 63
    • 0030271513 scopus 로고    scopus 로고
    • Fatigue performance of ultra-high-molecular-weight polyethylene: Effect of gamma radiation sterilization
    • W.L. Sauer, K.D. Weaver and N.B. Beals, Fatigue performance of ultra-high-molecular-weight polyethylene: effect of gamma radiation sterilization, Biomaterials 17 (1996), 1929-1935.
    • (1996) Biomaterials , vol.17 , pp. 1929-1935
    • Sauer, W.L.1    Weaver, K.D.2    Beals, N.B.3
  • 65
    • 0031105323 scopus 로고    scopus 로고
    • Polyethylene wear in total hip and knee arthroplasties
    • G. Lewis, Polyethylene wear in total hip and knee arthroplasties, J. Biomed. Mater, Res. (Appl. Biomater.) 38 (1997), 55-75.
    • (1997) J. Biomed. Mater, Res. (Appl. Biomater.) , vol.38 , pp. 55-75
    • Lewis, G.1
  • 68
    • 0029027099 scopus 로고
    • Effect of polyethylene quality on wear in total knee arthroplasty
    • M.B. Tanner, L.A. Whiteside and S.E. White, Effect of polyethylene quality on wear in total knee arthroplasty, Clin. Orthop. Rel. Res. 317 (1995), 83-88.
    • (1995) Clin. Orthop. Rel. Res. , vol.317 , pp. 83-88
    • Tanner, M.B.1    Whiteside, L.A.2    White, S.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.