메뉴 건너뛰기




Volumn 13, Issue 4, 1998, Pages 242-252

Laser resistance of endotracheal tubes I: Experimental results of a compound tube in comparison to a metallic tube

Author keywords

Laser safety; Laser surgery; Laser induced ignition of endotracheal tubes; Upper aerodigestive tract; Vaporisation cooling

Indexed keywords

METAL; POLYVINYL ACETATE; RUBBER;

EID: 0032436770     PISSN: 02688921     EISSN: None     Source Type: Journal    
DOI: 10.1007/s101030050003     Document Type: Article
Times cited : (6)

References (14)
  • 1
    • 0018670848 scopus 로고
    • Endotracheal tube ignition during laser surgery of the larynx
    • Burgess GE, LeJeune FE. Endotracheal tube ignition during laser surgery of the larynx. Ach Otolaryngol 1979; 105:561-2
    • (1979) Ach Otolaryngol , vol.105 , pp. 561-562
    • Burgess, G.E.1    LeJeune, F.E.2
  • 3
    • 0038034906 scopus 로고
    • Comparison of endotracheal tube safety during carbon dioxide laser surgery: An experimental study
    • Werner JA, Schade W, Jeckström W et al. Comparison of endotracheal tube safety during carbon dioxide laser surgery: an experimental study. Laser Med Surg 1990; 6:184-9
    • (1990) Laser Med Surg , vol.6 , pp. 184-189
    • Werner, J.A.1    Schade, W.2    Jeckström, W.3
  • 5
    • 0026611432 scopus 로고
    • 2 laser endotracheal tube fires with the Laser-Guard protective coating
    • 2 laser endotracheal tube fires with the Laser-Guard protective coating. J Clin Anesth 1992; 4:25-7
    • (1992) J Clin Anesth , vol.4 , pp. 25-27
    • Sosis, M.B.1    Francis, F.D.2
  • 6
    • 0002625196 scopus 로고
    • Laser resistance of endotracheal tubes
    • Foth H-J. Laser resistance of endotracheal tubes. Laser Optoelekt 1994; 26:53-60
    • (1994) Laser Optoelekt , vol.26 , pp. 53-60
    • Foth, H.-J.1
  • 8
    • 26444588250 scopus 로고    scopus 로고
    • Materials and constructions to improve the laser resistance of medical equipment
    • Foth H-J. Materials and constructions to improve the laser resistance of medical equipment. Proceedings of SPIE 1997; 2974:219-29
    • (1997) Proceedings of SPIE , vol.2974 , pp. 219-229
    • Foth, H.-J.1
  • 9
    • 0030006332 scopus 로고    scopus 로고
    • Evaluation of a new laser-resistant fabric and copper foil-wrapped endotracheal tube
    • Sosis MB, Braverman B, Caldarelli DD. Evaluation of a new laser-resistant fabric and copper foil-wrapped endotracheal tube. Laryngoscope 1996; 106:842-4
    • (1996) Laryngoscope , vol.106 , pp. 842-844
    • Sosis, M.B.1    Braverman, B.2    Caldarelli, D.D.3
  • 10
    • 0033017972 scopus 로고    scopus 로고
    • Laser resistance of endotracheal tubes II: Temperature rise and theoretical explanation
    • Foth H-J. Laser resistance of endotracheal tubes II: temperature rise and theoretical explanation. Lasers Med Sci
    • Lasers Med Sci
    • Foth, H.-J.1
  • 11
    • 0027141429 scopus 로고
    • Evaluation of a technique of nitrogen insufflation to decrease plastic endotracheal tube cuff flammability during carbon dioxide laser surgery
    • Sosis MB. Evaluation of a technique of nitrogen insufflation to decrease plastic endotracheal tube cuff flammability during carbon dioxide laser surgery. J Clin Anesth 1993; 5:468-70
    • (1993) J Clin Anesth , vol.5 , pp. 468-470
    • Sosis, M.B.1
  • 12
    • 0025854512 scopus 로고
    • Saline-filled cuffs help prevent laser-induced polychloride endotracheal tube fires
    • Sosis MD, Dillon FX. Saline-filled cuffs help prevent laser-induced polychloride endotracheal tube fires. Anesth Analg 1991; 72:187-9
    • (1991) Anesth Analg , vol.72 , pp. 187-189
    • Sosis, M.D.1    Dillon, F.X.2
  • 14
    • 0027339755 scopus 로고
    • Ignition of the Xomed, plastic and rubber endotracheal tubes
    • Sosis MB, Dillon FX. Ignition of the Xomed, plastic and rubber endotracheal tubes. Anesth Analg 1993; 76:391-3.
    • (1993) Anesth Analg , vol.76 , pp. 391-393
    • Sosis, M.B.1    Dillon, F.X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.