메뉴 건너뛰기




Volumn 19, Issue 6, 1998, Pages 463-472

Distortion product otoacoustic emission and auditory brain stem response measures of pediatric sensorineural hearing loss with islands of normal sensitivity

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ARTICLE; AUDITORY THRESHOLD; CHILD; CLINICAL ARTICLE; CONTROLLED STUDY; DISTORTION PRODUCT OTOACOUSTIC EMISSION; EVOKED BRAIN STEM AUDITORY RESPONSE; FEMALE; FREQUENCY ANALYSIS; HUMAN; MALE; PERCEPTION DEAFNESS; PURE TONE AUDIOMETRY;

EID: 0032428695     PISSN: 01960202     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003446-199812000-00007     Document Type: Article
Times cited : (14)

References (30)
  • 1
    • 0023941057 scopus 로고
    • Auditory brainstem responses as a function of average hearing sensitivity for 2000-4000 Hz
    • Bauch, C. D., & Olsen, W. O. (1988). Auditory brainstem responses as a function of average hearing sensitivity for 2000-4000 Hz. Audiology, 27, 156-163.
    • (1988) Audiology , vol.27 , pp. 156-163
    • Bauch, C.D.1    Olsen, W.O.2
  • 2
    • 0010554964 scopus 로고
    • Fundamentals of sound generation
    • E. Moore (Ed.), New York: Grune & Stratton
    • Durrant, J. D. (1983). Fundamentals of sound generation. In E. Moore (Ed.), Bases of auditory brainstem evoked responses (pp. 15-49). New York: Grune & Stratton.
    • (1983) Bases of Auditory Brainstem Evoked Responses , pp. 15-49
    • Durrant, J.D.1
  • 5
    • 0027404710 scopus 로고
    • A comparison of auditory brain stem response thresholds and latencies elicited by air- and bone-conducted stimuli
    • Gorga, M. P., Kaminski, J. R., Beauchaine, K. L., & Bergman, B. M. (1993). A comparison of auditory brain stem response thresholds and latencies elicited by air- and bone-conducted stimuli. Ear and Hearing, 14, 85-93.
    • (1993) Ear and Hearing , vol.14 , pp. 85-93
    • Gorga, M.P.1    Kaminski, J.R.2    Beauchaine, K.L.3    Bergman, B.M.4
  • 9
    • 0029790787 scopus 로고    scopus 로고
    • The use of cumulative distributions to determine critical values and levels of confidence for clinical distortion product otoacoustic emission measurements
    • Gorga, M. P., Stover, L., Neely, S. T., & Montoya, D. (1996). The use of cumulative distributions to determine critical values and levels of confidence for clinical distortion product otoacoustic emission measurements. Journal of the Acoustical Society of America, 100, 968-977.
    • (1996) Journal of the Acoustical Society of America , vol.100 , pp. 968-977
    • Gorga, M.P.1    Stover, L.2    Neely, S.T.3    Montoya, D.4
  • 10
    • 0024354094 scopus 로고
    • The choice of stimuli for ABR measurements
    • Gorga, M. P., & Thornton, A. R. (1989). The choice of stimuli for ABR measurements. Ear and Hearing, 10, 217-230.
    • (1989) Ear and Hearing , vol.10 , pp. 217-230
    • Gorga, M.P.1    Thornton, A.R.2
  • 11
    • 0021861488 scopus 로고
    • Some comparisons between auditory brain stem response thresholds, latencies, and the pure tone audiogram
    • Gorga, M. P., Worthington, D. W., Reiland, J. K., Beauchaine, K. A., & Goldgar, D. E. (1985). Some comparisons between auditory brain stem response thresholds, latencies, and the pure tone audiogram. Ear and Hearing, 6, 105-112.
    • (1985) Ear and Hearing , vol.6 , pp. 105-112
    • Gorga, M.P.1    Worthington, D.W.2    Reiland, J.K.3    Beauchaine, K.A.4    Goldgar, D.E.5
  • 12
    • 0019966122 scopus 로고
    • Auditory brainstem response (ABR) for tone-pips: Results in normal and hearing-impaired subjects
    • Hayes, D., & Jerger, J. (1982). Auditory brainstem response (ABR) for tone-pips: Results in normal and hearing-impaired subjects. Scandinavian Audiology, 11, 133-142.
    • (1982) Scandinavian Audiology , vol.11 , pp. 133-142
    • Hayes, D.1    Jerger, J.2
  • 13
    • 0023095297 scopus 로고
    • Effects of audiometric configuration on the auditory brain stem response
    • Keith, W. J., & Greville, K. A. (1987). Effects of audiometric configuration on the auditory brain stem response. Ear and Hearing, 8, 49-55.
    • (1987) Ear and Hearing , vol.8 , pp. 49-55
    • Keith, W.J.1    Greville, K.A.2
  • 14
    • 0019808233 scopus 로고
    • The frequency specificity of tone-pip evoked auditory brain stem responses
    • Kileny, P. (1981). The frequency specificity of tone-pip evoked auditory brain stem responses. Ear and Hearing, 2, 270-275.
    • (1981) Ear and Hearing , vol.2 , pp. 270-275
    • Kileny, P.1
  • 15
    • 0023395390 scopus 로고
    • Predictive value of ABR in infants and children with moderate to profound hearing impairment
    • Kileny, P. R., & Magathan, M. G. (1987). Predictive value of ABR in infants and children with moderate to profound hearing impairment. Ear and Hearing, 8, 217-221.
    • (1987) Ear and Hearing , vol.8 , pp. 217-221
    • Kileny, P.R.1    Magathan, M.G.2
  • 17
    • 0024605179 scopus 로고
    • Frequency specific auditory brainstem responses. Effective masking levels and relationship to behavioural thresholds in normal hearing adults
    • Purdy, S. C., Houghton, J. M., Keith, W. J., & Greville, K. A. (1989). Frequency specific auditory brainstem responses. Effective masking levels and relationship to behavioural thresholds in normal hearing adults. Audiology, 28, 82-91.
    • (1989) Audiology , vol.28 , pp. 82-91
    • Purdy, S.C.1    Houghton, J.M.2    Keith, W.J.3    Greville, K.A.4
  • 18
    • 0027236353 scopus 로고
    • Repeatability of distortion product otoacoustic emissions in normally hearing humans
    • Roede, J., Harris, F. P., Probst, R., & Xu, L. (1993). Repeatability of distortion product otoacoustic emissions in normally hearing humans. Audiology, 32, 273-281.
    • (1993) Audiology , vol.32 , pp. 273-281
    • Roede, J.1    Harris, F.P.2    Probst, R.3    Xu, L.4
  • 19
    • 0028357452 scopus 로고
    • Ear-canal standing waves and high-frequency sound calibration using otoacoustic emission probes
    • Siegel, J. H. (1994). Ear-canal standing waves and high-frequency sound calibration using otoacoustic emission probes. Journal of the Acoustical Society of America, 95, 2589-2597.
    • (1994) Journal of the Acoustical Society of America , vol.95 , pp. 2589-2597
    • Siegel, J.H.1
  • 21
    • 0024341453 scopus 로고
    • Auditory brainstem response assessment of infants and children
    • Stapells, D. R. (1989). Auditory brainstem response assessment of infants and children. Seminars in Hearing, 10, 229-251.
    • (1989) Seminars in Hearing , vol.10 , pp. 229-251
    • Stapells, D.R.1
  • 22
    • 0345082828 scopus 로고
    • Low-frequency hearing and the auditory brainstem responses
    • Stapells, D. R. (1994). Low-frequency hearing and the auditory brainstem responses. American Journal of Audiology, 3, 11-13.
    • (1994) American Journal of Audiology , vol.3 , pp. 11-13
    • Stapells, D.R.1
  • 23
    • 0029123735 scopus 로고
    • Thresholds for auditory brain stem responses to tones in notched noise from infants and young children with normal hearing or sensorineural hearing loss
    • Stapells, D. R., Gravel, J. S., & Martin, B. A. (1995). Thresholds for auditory brain stem responses to tones in notched noise from infants and young children with normal hearing or sensorineural hearing loss. Ear and Hearing, 16, 361-371.
    • (1995) Ear and Hearing , vol.16 , pp. 361-371
    • Stapells, D.R.1    Gravel, J.S.2    Martin, B.A.3
  • 24
    • 0002179537 scopus 로고
    • Electrophysiologic measures of frequency-specific auditory function
    • J. T. Jacobson (Ed.), Needham Heights, MA: Allyn & Bacon
    • Stapells, D. R., Picton, T. W., & Durieux-Smith, A. (1994). Electrophysiologic measures of frequency-specific auditory function. In: J. T. Jacobson (Ed.), Principles and applications in auditory evoked potentials (pp. 251-283). Needham Heights, MA: Allyn & Bacon.
    • (1994) Principles and Applications in Auditory Evoked Potentials , pp. 251-283
    • Stapells, D.R.1    Picton, T.W.2    Durieux-Smith, A.3
  • 25
    • 0029788653 scopus 로고    scopus 로고
    • Toward optimizing the clinical utility of distortion product otoacoustic emission measurements
    • Stover, L., Gorga, M. P., & Neely, S. T. (1996). Toward optimizing the clinical utility of distortion product otoacoustic emission measurements. Journal of the Acoustical Society of America, 100, 956-967.
    • (1996) Journal of the Acoustical Society of America , vol.100 , pp. 956-967
    • Stover, L.1    Gorga, M.P.2    Neely, S.T.3
  • 26
    • 0023736907 scopus 로고
    • Brainstem response audiometry: I. Its use in distinguishing between conductive and cochlear hearing loss
    • van der Drift, J. F. C., Brocaar, M. P., & van Zanten, G. A. (1988a). Brainstem response audiometry: I. Its use in distinguishing between conductive and cochlear hearing loss. Audiology, 27, 260-270.
    • (1988) Audiology , vol.27 , pp. 260-270
    • Van Der Drift, J.F.C.1    Brocaar, M.P.2    Van Zanten, G.A.3
  • 27
    • 0023780377 scopus 로고
    • Brainstem response audiometry: II. Classification of hearing loss by discriminant analysis
    • van der Drift, J. F. C., Brocaar, M. P., & van Zanten, G. A. (1988b). Brainstem response audiometry: II. Classification of hearing loss by discriminant analysis. Audiology, 27, 271-278.
    • (1988) Audiology , vol.27 , pp. 271-278
    • Van Der Drift, J.F.C.1    Brocaar, M.P.2    Van Zanten, G.A.3
  • 30
    • 0018769705 scopus 로고
    • Cochlear processes affecting wave V latency of the auditory evoked brainstem response: A study of patients with sensory hearing loss
    • Yamada, O., Kodera, K., & Yagi, T. (1979). Cochlear processes affecting wave V latency of the auditory evoked brainstem response: A study of patients with sensory hearing loss. Scandinavian Audiology, 8, 67-70.
    • (1979) Scandinavian Audiology , vol.8 , pp. 67-70
    • Yamada, O.1    Kodera, K.2    Yagi, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.