메뉴 건너뛰기




Volumn 25, Issue 12, 1998, Pages 2392-2399

Intracavitary ultrasound phased arrays for prostate thermal therapies: MRI compatibility and in vivo testing

Author keywords

Aperiodic; Hyperthermia; Intracavitary; MRI; Phased array; Prostate; Thermal surgery; Thermal therapy; Transrectal; Ultrasound surgery

Indexed keywords

ANTENNA PHASED ARRAYS; DISEASES; HYPERTHERMIA THERAPY; MAGNETIC RESONANCE IMAGING; SURGERY; UROLOGY;

EID: 0032427804     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598450     Document Type: Article
Times cited : (32)

References (25)
  • 2
    • 0027174186 scopus 로고
    • Feasibility and toxicity of transrectal ultrasound hyperthermia treatment of locally advanced adenocarcinoma of the prostate
    • H. Fosmire, K. Hynynen, G. W. Drach, B. Stea, P. Swift, and J. R. Cassady, "Feasibility and toxicity of transrectal ultrasound hyperthermia treatment of locally advanced adenocarcinoma of the prostate," Int. J. Radiat. Oncol., Biol., Phys. 23, 253-259 (1993).
    • (1993) Int. J. Radiat. Oncol., Biol., Phys. , vol.23 , pp. 253-259
    • Fosmire, H.1    Hynynen, K.2    Drach, G.W.3    Stea, B.4    Swift, P.5    Cassady, J.R.6
  • 3
    • 0027298585 scopus 로고
    • High-intensity focused ultrasound in the treatment of prostatic disease
    • R. S. Foster, R. Bihrle, N. T. Sanghvi, F. J. Fry, and J. P. Donohue, "High-intensity focused ultrasound in the treatment of prostatic disease," Eur. Urol. 23, 29-33 (1993).
    • (1993) Eur. Urol. , vol.23 , pp. 29-33
    • Foster, R.S.1    Bihrle, R.2    Sanghvi, N.T.3    Fry, F.J.4    Donohue, J.P.5
  • 4
    • 0027256093 scopus 로고
    • High-intensity focused ultrasound experimentation on benign prostatic hypertrophy
    • A. Gelet, J. Y. Chapelon, and J. Margonari, "High-intensity focused ultrasound experimentation on benign prostatic hypertrophy," Eur. Urol. 23, 44-47 (1993).
    • (1993) Eur. Urol. , vol.23 , pp. 44-47
    • Gelet, A.1    Chapelon, J.Y.2    Margonari, J.3
  • 6
    • 0026155548 scopus 로고
    • The feasibility of using electrically focused ultrasound arrays to induce deep hyperthermia via body cavities
    • C. J. Diederich and K. Hynynen, "The feasibility of using electrically focused ultrasound arrays to induce deep hyperthermia via body cavities," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 38, 207-219 (1991).
    • (1991) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.38 , pp. 207-219
    • Diederich, C.J.1    Hynynen, K.2
  • 8
    • 0028630512 scopus 로고
    • Design and experimental evaluation of an intracavitary ultrasound phased array system for hyperthermia
    • M. T. Buchanan and K. Hynynen, "Design and experimental evaluation of an intracavitary ultrasound phased array system for hyperthermia," IEEE Trans. Biomed. Eng. 41, 1178-1187 (1994).
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , pp. 1178-1187
    • Buchanan, M.T.1    Hynynen, K.2
  • 9
    • 0029974783 scopus 로고    scopus 로고
    • Design and optimization of an ultrasound phased array for prostate thermal therapies
    • E. B. Hutchinson, M. T. Buchanan, and K. Hynynen, "Design and optimization of an ultrasound phased array for prostate thermal therapies," Med. Phys. 23, 767-776 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 767-776
    • Hutchinson, E.B.1    Buchanan, M.T.2    Hynynen, K.3
  • 12
    • 9944225623 scopus 로고
    • Dependence of the electromechanical coupling coefficient on the width-to-thickness ratio of plank shaped piezoelectric transducers used for electronically scanned ultrasound diagnostic systems
    • J. Sato, M. Kawabuchi, and A. Fukumoto, "Dependence of the electromechanical coupling coefficient on the width-to-thickness ratio of plank shaped piezoelectric transducers used for electronically scanned ultrasound diagnostic systems," J. Acoust. Soc. Am. 66, 1609-1611 (1979).
    • (1979) J. Acoust. Soc. Am. , vol.66 , pp. 1609-1611
    • Sato, J.1    Kawabuchi, M.2    Fukumoto, A.3
  • 13
    • 0025431701 scopus 로고
    • Optimizing ultrasonic transducers based on piezoelectric composites using a finite-element method
    • P. Challande, "Optimizing ultrasonic transducers based on piezoelectric composites using a finite-element method," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 37, 135-140 (1990).
    • (1990) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.37 , pp. 135-140
    • Challande, P.1
  • 14
  • 15
    • 0029347489 scopus 로고
    • Non-invasive estimation of tissue temperature response to heating fields using diagnostic ultrasound
    • R. Seip and E. S. Ebbini, "Non-invasive estimation of tissue temperature response to heating fields using diagnostic ultrasound," IEEE Trans. Biomed. Eng. 42, 828-839 (1995).
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , pp. 828-839
    • Seip, R.1    Ebbini, E.S.2
  • 16
    • 6844262260 scopus 로고    scopus 로고
    • Temperature imaging by proton chemical shift
    • CRC Press, Boca Raton
    • K. Kuroda and S. Tsutsumi, "Temperature imaging by proton chemical shift," Non-Invasive Thermometry of the Human Body (CRC Press, Boca Raton, 1996), pp. 63-103.
    • (1996) Non-Invasive Thermometry of the Human Body , pp. 63-103
    • Kuroda, K.1    Tsutsumi, S.2
  • 17
    • 0014972416 scopus 로고
    • Beam behavior within the nearfield of a vibrating piston
    • J. Zemanek, "Beam behavior within the nearfield of a vibrating piston," J. Acoust. Soc. Am. 49, 181-191 (1971).
    • (1971) J. Acoust. Soc. Am. , vol.49 , pp. 181-191
    • Zemanek, J.1
  • 18
    • 84888360034 scopus 로고
    • Analysis of tissue and arterial blood temperatures in the resting human forearm
    • H. H. Pennes, "Analysis of tissue and arterial blood temperatures in the resting human forearm," J. Appl. Physiol. 1, 93-122 (1948).
    • (1948) J. Appl. Physiol. , vol.1 , pp. 93-122
    • Pennes, H.H.1
  • 19
    • 0002976643 scopus 로고
    • Ultrasonic measurement techniques and equipment output levels
    • edited by M. H. Repacholi and D. A. Bemvell Humana, Clifton, NJ
    • H. F. Stewart, "Ultrasonic measurement techniques and equipment output levels," in Essentials of Medical Ultrasound, edited by M. H. Repacholi and D. A. Bemvell (Humana, Clifton, NJ, 1982), pp. 77-116.
    • (1982) Essentials of Medical Ultrasound , pp. 77-116
    • Stewart, H.F.1
  • 20
    • 0027532146 scopus 로고
    • Acoustic power calibrations of cylindrical intracavitary ultrasound hyperthermia applicators
    • K. Hynynen, "Acoustic power calibrations of cylindrical intracavitary ultrasound hyperthermia applicators," Med. Phys. 20, 129-134 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 129-134
    • Hynynen, K.1
  • 22
    • 0029958301 scopus 로고    scopus 로고
    • Optimization of spoiled gradient-echo imaging for in vivo localization of a focused ultrasound beam
    • A. H. Chung, K. Hynynen, V. Colucci, K. Oshio, H. E. Cline, and F. A. Jolesz, "Optimization of spoiled gradient-echo imaging for in vivo localization of a focused ultrasound beam," Magn. Reson. Med. 36, 745-752 (1996).
    • (1996) Magn. Reson. Med. , vol.36 , pp. 745-752
    • Chung, A.H.1    Hynynen, K.2    Colucci, V.3    Oshio, K.4    Cline, H.E.5    Jolesz, F.A.6
  • 23
    • 0031965608 scopus 로고    scopus 로고
    • The feasibility of MRI feedback control for intracavitary phased array hyperthermia treatments
    • E. Hutchinson, M. Dahleh, and K. Hynynen, "The feasibility of MRI feedback control for intracavitary phased array hyperthermia treatments," Int. J. Hyperthermia 14, 39-56 (1998).
    • (1998) Int. J. Hyperthermia , vol.14 , pp. 39-56
    • Hutchinson, E.1    Dahleh, M.2    Hynynen, K.3
  • 25
    • 0028299454 scopus 로고
    • The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery
    • C. Damianou and K. Hynynen, "The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery," J. Acoust. Soc. Am. 95, 1641-1649 (1994).
    • (1994) J. Acoust. Soc. Am. , vol.95 , pp. 1641-1649
    • Damianou, C.1    Hynynen, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.