Volumn 13, Issue 4, 1998, Pages 190-197

Clinical trial of an ex vivo arterial blood gas monitor

Author keywords

[No Author keywords available]

Indexed keywords

CARBON DIOXIDE; OXYGEN;

EID: 0032413137     PISSN: 08839441     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-9441(98)90005-3     Document Type: Article
Times cited : (9)

References (32)
  • 2
    • 0027261080 scopus 로고
    • Does implementing pulse oximetry in a critical care unit result in substantial arterial blood gas savings?
    • Inman KJ, Sibbald WJ, Rutledge FS, et al: Does implementing pulse oximetry in a critical care unit result in substantial arterial blood gas savings? Chest 104:542-546, 1993
    • (1993) Chest , vol.104 , pp. 542-546
    • Inman, K.J.1    Sibbald, W.J.2    Rutledge, F.S.3
  • 3
    • 0030750593 scopus 로고    scopus 로고
    • Practice guideline for arterial blood gas measurement in the intensive care unit decreases numbers and increases appropriateness of tests
    • Pilon CS, Leathley M, London R, et al: Practice guideline for arterial blood gas measurement in the intensive care unit decreases numbers and increases appropriateness of tests. Crit Care Med 25:1308-1313, 1997
    • (1997) Crit Care Med , vol.25 , pp. 1308-1313
    • Pilon, C.S.1    Leathley, M.2    London, R.3
  • 4
    • 0031011407 scopus 로고    scopus 로고
    • Evaluating laboratory usage in the intensive care unit: Patient and institutional characteristics that influence frequency of blood sampling
    • Zimmerman JE, Seneff MG, Sun X, et al: Evaluating laboratory usage in the intensive care unit: Patient and institutional characteristics that influence frequency of blood sampling. Crit Care Med 25:737-748, 1997
    • (1997) Crit Care Med , vol.25 , pp. 737-748
    • Zimmerman, J.E.1    Seneff, M.G.2    Sun, X.3
  • 5
    • 0027203089 scopus 로고
    • Performance of Gem Premier blood gas/electrolyte analyzer evaluated
    • Jacobs E, Nowakowski M, Colman N: Performance of Gem Premier blood gas/electrolyte analyzer evaluated. Clin Chem 39:1890-1893, 1993
    • (1993) Clin Chem , vol.39 , pp. 1890-1893
    • Jacobs, E.1    Nowakowski, M.2    Colman, N.3
  • 6
    • 0027424672 scopus 로고
    • Near-patient blood gas and electrolyte analyses are accurate when performed by non-laboratory-trained individuals
    • Zaloga GP, Dudas L, Roberts P, et al: Near-patient blood gas and electrolyte analyses are accurate when performed by non-laboratory-trained individuals. J Clin Monit 9:341-346, 1993
    • (1993) J Clin Monit , vol.9 , pp. 341-346
    • Zaloga, G.P.1    Dudas, L.2    Roberts, P.3
  • 7
    • 0028787605 scopus 로고
    • Point-of-care testing in the intensive care unit: The intensive care physician's perspective
    • Castro HJ, Oropello JM, Halpern N: Point-of-care testing in the intensive care unit: The intensive care physician's perspective. Am J Clin Pathol 104:895-899, 1995 (suppl 1)
    • (1995) Am J Clin Pathol , vol.104 , Issue.1 SUPPL. , pp. 895-899
    • Castro, H.J.1    Oropello, J.M.2    Halpern, N.3
  • 9
    • 0030199178 scopus 로고    scopus 로고
    • Accuracy and precision of a new, portable, handheld blood gas analyzer, the IRMA
    • Wahr JA, Lau W, Tremper KK, et al: Accuracy and precision of a new, portable, handheld blood gas analyzer, the IRMA. J Clin Monit 12:317-324, 1996
    • (1996) J Clin Monit , vol.12 , pp. 317-324
    • Wahr, J.A.1    Lau, W.2    Tremper, K.K.3
  • 10
    • 0030014696 scopus 로고    scopus 로고
    • Hand-held blood gas analyzer is accurate in the critical care setting
    • Zaloga GP, Roberts PR, Black K, et al: Hand-held blood gas analyzer is accurate in the critical care setting. Crit Care Med 24:957-962, 1996
    • (1996) Crit Care Med , vol.24 , pp. 957-962
    • Zaloga, G.P.1    Roberts, P.R.2    Black, K.3
  • 11
    • 0031194621 scopus 로고    scopus 로고
    • Evaluation of i-STAT portable clinical analyzer in a neonatal and pediatric intensive care unit
    • Murthy JN, Hicks JM, Soldin SJ: Evaluation of i-STAT portable clinical analyzer in a neonatal and pediatric intensive care unit. Clin Biochem 30:385-389, 1997
    • (1997) Clin Biochem , vol.30 , pp. 385-389
    • Murthy, J.N.1    Hicks, J.M.2    Soldin, S.J.3
  • 12
    • 0029056488 scopus 로고
    • Optical sensors for clinical monitoring
    • Lubbers DW: Optical sensors for clinical monitoring. Acta Anaesthesiol Scand 39:37-54, 1995 (suppl 104)
    • (1995) Acta Anaesthesiol Scand , vol.39 , Issue.104 SUPPL. , pp. 37-54
    • Lubbers, D.W.1
  • 13
    • 0027413775 scopus 로고
    • Initial evaluation of a new intra-arterial blood gas system in humans
    • Zimmerman JL, Dellinger RP: Initial evaluation of a new intra-arterial blood gas system in humans. Crit Care Med 21:495-500, 1993
    • (1993) Crit Care Med , vol.21 , pp. 495-500
    • Zimmerman, J.L.1    Dellinger, R.P.2
  • 14
    • 0028265076 scopus 로고
    • Continuous intraarterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: A prospective, criterion standard study
    • Haller M, Kilger E, Briegel J, et al: Continuous intraarterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: A prospective, criterion standard study. Crit Care Med 22:580-587, 1994
    • (1994) Crit Care Med , vol.22 , pp. 580-587
    • Haller, M.1    Kilger, E.2    Briegel, J.3
  • 15
    • 0028214567 scopus 로고
    • A multiparameter sensor for continuous intra-arterial blood gas monitoring: A prospective evaluation
    • Venkatesh B, Glutton-Brock TH, Henry SP: A multiparameter sensor for continuous intra-arterial blood gas monitoring: A prospective evaluation. Crit Care Med 22:588-594, 1994
    • (1994) Crit Care Med , vol.22 , pp. 588-594
    • Venkatesh, B.1    Glutton-Brock, T.H.2    Henry, S.P.3
  • 16
    • 0027420041 scopus 로고
    • Clinical performance of a blood gas monitor: A prospective, multicenter trial
    • Shapiro BA, Mahutte CK, Cane RD, et al: Clinical performance of a blood gas monitor: A prospective, multicenter trial. Crit Care Med 21:487-494, 1993
    • (1993) Crit Care Med , vol.21 , pp. 487-494
    • Shapiro, B.A.1    Mahutte, C.K.2    Cane, R.D.3
  • 17
    • 0027930990 scopus 로고
    • Performance of a patient-dedicated, on-demand blood gas monitor in medical ICU patients
    • Mahutte CK, Sasse SA, Chen PA, et al: Performance of a patient-dedicated, on-demand blood gas monitor in medical ICU patients. Am J Respir Crit Care Med 150:865-869, 1994
    • (1994) Am J Respir Crit Care Med , vol.150 , pp. 865-869
    • Mahutte, C.K.1    Sasse, S.A.2    Chen, P.A.3
  • 18
    • 0029215455 scopus 로고
    • Bedside arterial blood gas monitoring system using fluorescent optical sensors
    • Society for Photooptical Instrumentation Engineers (SPIE)-International Society for Optical Engineering
    • Bartnik DJ, Rymut RA: Bedside arterial blood gas monitoring system using fluorescent optical sensors. Advances in Fluorescence Sensing Technology, Society for Photooptical Instrumentation Engineers (SPIE)-International Society for Optical Engineering 2388:529-539, 1995
    • (1995) Advances in Fluorescence Sensing Technology , vol.2388 , pp. 529-539
    • Bartnik, D.J.1    Rymut, R.A.2
  • 19
    • 0031446286 scopus 로고    scopus 로고
    • Preliminary clinical trial of an ex vivo arterial blood gas monitor
    • McKinley BA, Parmley CL: Preliminary clinical trial of an ex vivo arterial blood gas monitor. J Crit Care 12:1-8, 1997
    • (1997) J Crit Care , vol.12 , pp. 1-8
    • McKinley, B.A.1    Parmley, C.L.2
  • 20
    • 0023635052 scopus 로고
    • Minimum discard volume from arterial catheters to obtain coagulation studies free of heparin effect
    • Rakowski-Reinhardt AC, Tonnesen AS, Bracey A, et al: Minimum discard volume from arterial catheters to obtain coagulation studies free of heparin effect. Heart Lung 16:699-705, 1987
    • (1987) Heart Lung , vol.16 , pp. 699-705
    • Rakowski-Reinhardt, A.C.1    Tonnesen, A.S.2    Bracey, A.3
  • 21
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310, 1986
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 13044305827 scopus 로고
    • 2 precision: The effect of averaging multiple samples
    • 2 precision: The effect of averaging multiple samples. Chest 98:33S, 1990 (suppl)
    • (1990) Chest , vol.98 , Issue.SUPPL.
    • Jensen, R.L.1    Crapo, R.O.2    Henderson, S.E.3
  • 23
    • 2842557566 scopus 로고
    • A side-by-side comparison of four blood gas analyzers using tonometered human blood
    • MacGregor DA, Scuderi PE, Bowton DL, et al: A side-by-side comparison of four blood gas analyzers using tonometered human blood. Chest 98:33S, 1990 (suppl)
    • (1990) Chest , vol.98 , Issue.SUPPL.
    • MacGregor, D.A.1    Scuderi, P.E.2    Bowton, D.L.3
  • 25
    • 0028195082 scopus 로고
    • Evaluation of blood gas monitors: Performance criteria, clinical impact, and cost/benefit
    • Shapiro BA: Evaluation of blood gas monitors: Performance criteria, clinical impact, and cost/benefit. Crit Care Med 22:546-549, 1994
    • (1994) Crit Care Med , vol.22 , pp. 546-549
    • Shapiro, B.A.1
  • 26
    • 0030974635 scopus 로고    scopus 로고
    • Instrumental variability of respiratory blood gases among different blood gas analysers in different laboratories
    • Kampelmacher MJ, van Kesteren RG, Winckers EK: Instrumental variability of respiratory blood gases among different blood gas analysers in different laboratories. Eur Respir J 10:1341-1344, 1997
    • (1997) Eur Respir J , vol.10 , pp. 1341-1344
    • Kampelmacher, M.J.1    Van Kesteren, R.G.2    Winckers, E.K.3
  • 27
    • 85030350441 scopus 로고
    • Section 3: Clinical chemistry, therapeutic drug monitoring, toxicology, endocrinology, ligands
    • Northfield, IL, College of American Pathologists
    • Section 3: Clinical chemistry, therapeutic drug monitoring, toxicology, endocrinology, ligands. 1995 CAP Surveys. Northfield, IL, College of American Pathologists, 1995, pp 7-8
    • (1995) 1995 CAP Surveys , pp. 7-8
  • 28
    • 0028881732 scopus 로고
    • Regulatory requirements (CLIA '88, JCAHO, CAP) for decentralized testing
    • Ehrmeyer SS, Laessig RH: Regulatory requirements (CLIA '88, JCAHO, CAP) for decentralized testing. Am J Clin Pathol 104:S40-S49, 1995 (suppl 1)
    • (1995) Am J Clin Pathol , vol.104 , Issue.1 SUPPL.
    • Ehrmeyer, S.S.1    Laessig, R.H.2
  • 29
    • 0028286848 scopus 로고
    • Development of a patient-dedicated, on-demand, blood gas monitor
    • Mahutte CK, Holody M, Maxwell TP, et al: Development of a patient-dedicated, on-demand, blood gas monitor. Am J Respir Crit Care Med 149:852-859, 1994
    • (1994) Am J Respir Crit Care Med , vol.149 , pp. 852-859
    • Mahutte, C.K.1    Holody, M.2    Maxwell, T.P.3
  • 30
    • 85030345264 scopus 로고    scopus 로고
    • Evaluation of a new automated bedside blood gas and chemistry analyzer
    • Bailey PL, Lu JK, Cluff ML, et al: Evaluation of a new automated bedside blood gas and chemistry analyzer. Anesthesiology 87:A432, 1997
    • (1997) Anesthesiology , vol.87
    • Bailey, P.L.1    Lu, J.K.2    Cluff, M.L.3
  • 31
    • 0025183494 scopus 로고
    • ABGs and arterial lines: The relationship to unnecessarily drawn arterial blood gas samples
    • Muakkassa FF, Rutledge R, Fakhry SM, et al: ABGs and arterial lines: The relationship to unnecessarily drawn arterial blood gas samples. J Trauma 30:1087-1093, 1990
    • (1990) J Trauma , vol.30 , pp. 1087-1093
    • Muakkassa, F.F.1    Rutledge, R.2    Fakhry, S.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.