메뉴 건너뛰기




Volumn 169, Issue 6, 1998, Pages 658-661

Paired inspiratory and expiratory thin-section CT of the lung: Impact of spirometric gating;Stellenwert der spirometer-triggerung fur die hochauflosende computertomographie der lunge in inspiration und exspiration

Author keywords

Computed tomography (CT), quantitative; Computed tomography (CT), technology; Computed tomography (CT), thin section; Lung, density, spirometric control

Indexed keywords

ADULT; ARTICLE; CHRONIC OBSTRUCTIVE LUNG DISEASE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC IMAGING; EXPIRED AIR; FEMALE; HUMAN; INSPIRATORY CAPACITY; LUNG FUNCTION; MALE; PRIORITY JOURNAL; SPIROMETRY; AGED; EQUIPMENT DESIGN; INSTRUMENTATION; LUNG DISEASE; LUNG VENTILATION; MIDDLE AGED; PHYSIOLOGY; RADIODENSITOMETRY; RADIOGRAPHY; REFERENCE VALUE; SENSITIVITY AND SPECIFICITY;

EID: 0032411919     PISSN: 09366652     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (15)

References (13)
  • 1
    • 0343471502 scopus 로고    scopus 로고
    • Erfassung von Parenchymveränderungen der Lunge bei Rauchern durch hochauflösende Computertomographie
    • Müller-Leisse C, Otto A, Berger F, Schmitz E, Günther RW: Erfassung von Parenchymveränderungen der Lunge bei Rauchern durch hochauflösende Computertomographie. Fortschr Röntgenstr 1997; 166: 108-114
    • (1997) Fortschr Röntgenstr , vol.166 , pp. 108-114
    • Müller-Leisse, C.1    Otto, A.2    Berger, F.3    Schmitz, E.4    Günther, R.W.5
  • 4
    • 0025349284 scopus 로고
    • Measurement of pulmonary parenchymal attenuation: Use of spirometric gating with quantitative CT
    • Kalender WA, Rienmüller R, Seissler W, Behr J. Welke M, Fichte H: Measurement of pulmonary parenchymal attenuation: use of spirometric gating with quantitative CT. Radiology 1990; 175: 265-268
    • (1990) Radiology , vol.175 , pp. 265-268
    • Kalender, W.A.1    Rienmüller, R.2    Seissler, W.3    Behr, J.4    Welke, M.5    Fichte, H.6
  • 6
    • 0028932741 scopus 로고
    • Die quantitative Computertomographie der Lunge in der Frühdiagnose: Erste Erfahrungen an asbestexponierten Marinesoldaten
    • Reuter M, Holling I, Emde L, Brinkmann G, Bettinghausen E, Szadkowski D, Heller M: Die quantitative Computertomographie der Lunge in der Frühdiagnose: erste Erfahrungen an asbestexponierten Marinesoldaten. Fortschr Röntgenstr 1995; 162: 288-295
    • (1995) Fortschr Röntgenstr , vol.162 , pp. 288-295
    • Reuter, M.1    Holling, I.2    Emde, L.3    Brinkmann, G.4    Bettinghausen, E.5    Szadkowski, D.6    Heller, M.7
  • 7
    • 0025891909 scopus 로고
    • Semiautomatic evaluation procedures for quantitative CT of the lung
    • Kalender WA, Fichte H, Bautz W, Skalej M: Semiautomatic evaluation procedures for quantitative CT of the lung. J Comput Assist Tomogr 1991; 15: 248-255
    • (1991) J Comput Assist Tomogr , vol.15 , pp. 248-255
    • Kalender, W.A.1    Fichte, H.2    Bautz, W.3    Skalej, M.4
  • 8
  • 10
  • 11
    • 0021326052 scopus 로고
    • Thoracic gas volume measurement. Increased variability in patients with obstructive ventilator defects
    • Garcia JG, Hunninghake GW, Nugent KM: Thoracic gas volume measurement. Increased variability in patients with obstructive ventilator defects. Chest 1984; 85: 272-275
    • (1984) Chest , vol.85 , pp. 272-275
    • Garcia, J.G.1    Hunninghake, G.W.2    Nugent, K.M.3
  • 12
    • 0019387335 scopus 로고
    • Changes in measured spirometric indices: What is significant?
    • Pennock B, Rogers RM, McCaffree D: Changes in measured spirometric indices: what is significant? Chest 1981; 80: 97-99
    • (1981) Chest , vol.80 , pp. 97-99
    • Pennock, B.1    Rogers, R.M.2    McCaffree, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.