메뉴 건너뛰기




Volumn 82, Issue 11, 1998, Pages 1428-1430

Comparison of echocardiographic acoustic quantification with off-line manual tracing for determining left ventricular volume and ejection fraction in pediatric patients

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTICS; ARTICLE; CHILD; CLINICAL ARTICLE; COMPARATIVE STUDY; ECHOCARDIOGRAPHY; FEMALE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE VOLUME; HUMAN; MALE; PRIORITY JOURNAL; QUANTITATIVE ASSAY; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 0032374027     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(98)00656-0     Document Type: Article
Times cited : (4)

References (7)
  • 2
    • 0026565376 scopus 로고
    • On-line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imaging
    • 2. Perez JE, Waggoner AD, Barzilai B, Melton HE, Miller HG, Sobel BE. On-line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imaging. J Am Coll Cardiol 1992;19:313-320.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 313-320
    • Perez, J.E.1    Waggoner, A.D.2    Barzilai, B.3    Melton, H.E.4    Miller, H.G.5    Sobel, B.E.6
  • 3
    • 0026632428 scopus 로고
    • Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system
    • 3. Vandenberg BF, Rath LS, Stuhlmuller P, Melton HE, Skorton DJ. Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system. Circulation 1992;86:159-166.
    • (1992) Circulation , vol.86 , pp. 159-166
    • Vandenberg, B.F.1    Rath, L.S.2    Stuhlmuller, P.3    Melton, H.E.4    Skorton, D.J.5
  • 5
    • 0027385310 scopus 로고
    • Comparison of left ventricular function by echocardiographic automated border detection and by radionuclide ejection fraction
    • 5. Gorscan J, Lazar JM, Schulman DS, Follansbee WP. Comparison of left ventricular function by echocardiographic automated border detection and by radionuclide ejection fraction. Am J Cardiol 1993;72:810-815.
    • (1993) Am J Cardiol , vol.72 , pp. 810-815
    • Gorscan, J.1    Lazar, J.M.2    Schulman, D.S.3    Follansbee, W.P.4
  • 6
    • 0030090212 scopus 로고    scopus 로고
    • Assessment of diastolic left ventricular filling by echocardiographic automated border detection and comparison with radionuclide ventriculography
    • 6. Vitarelli A, Penco M, Ferro-Luzzi M, Rosanio S, Dagianti A, Fedele F, Dagianti A. Assessment of diastolic left ventricular filling by echocardiographic automated border detection and comparison with radionuclide ventriculography. J Am Soc Echocardiogr 1996;9:135-146.
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 135-146
    • Vitarelli, A.1    Penco, M.2    Ferro-Luzzi, M.3    Rosanio, S.4    Dagianti, A.5    Fedele, F.6    Dagianti, A.7
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 7. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;2:307-310.
    • (1986) Lancet , vol.2 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.