메뉴 건너뛰기




Volumn 31, Issue 1, 1998, Pages 101-105

Evaluation of two types of biosensors for immunoassay of botulinum toxin

Author keywords

Biosensor; Botulinium toxin; Light addressable potentiometric sensor; Surface plasmon resonance sensor

Indexed keywords


EID: 0032351494     PISSN: 12258687     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (14)

References (7)
  • 1
    • 0028447041 scopus 로고
    • Applying silicon micromachining to cellular metabolism
    • Bousse, L. and Parce, W. (1994) Applying silicon micromachining to cellular metabolism. IEEE Engineering in Medicine and Biology June/July, 396-401.
    • (1994) IEEE Engineering in Medicine and Biology , vol.JUNE-JULY , pp. 396-401
    • Bousse, L.1    Parce, W.2
  • 3
    • 0028123835 scopus 로고
    • Enzyme linked immunosoebent assay and enzyme linked coagulation assay for detection of antibodies to Clostridium botulinum neurotoxin-A, neurotoxin-B and neurotoxin-E and solution phase complexes
    • Doellgast, G. J., Beard, G. A., Bottoms, J. D., Cheng, T., Roh, B. H., Roman, M. G., Hall, P. A., and Triscott, M. X. (1994) Enzyme linked immunosoebent assay and enzyme linked coagulation assay for detection of antibodies to Clostridium botulinum neurotoxin-A, neurotoxin-B and neurotoxin-E and solution phase complexes. J. Clin. Microbiol. 32, 105-111.
    • (1994) J. Clin. Microbiol. , vol.32 , pp. 105-111
    • Doellgast, G.J.1    Beard, G.A.2    Bottoms, J.D.3    Cheng, T.4    Roh, B.H.5    Roman, M.G.6    Hall, P.A.7    Triscott, M.X.8
  • 4
    • 0025782533 scopus 로고
    • Principles and sensitivities of integrated optical and surface-plasmon sensors for direct affinity sensing and immunosensing
    • Lukosz, W. (1991) Principles and sensitivities of integrated optical and surface-plasmon sensors for direct affinity sensing and immunosensing. Biosens. Bioelectron. 6, 215-225.
    • (1991) Biosens. Bioelectron. , vol.6 , pp. 215-225
    • Lukosz, W.1
  • 5
    • 0002923670 scopus 로고
    • Assay for botulinum and tetanus toxin
    • Simpson, L. L. (ed.) Academic Press, New York
    • Notormans, S. and Nagel, J. (1989) Assay for botulinum and tetanus toxin, in Botulinum neurotoxin and Tetanus Toxin, Simpson, L. L. (ed.) pp. 319-365, Academic Press, New York.
    • (1989) Botulinum Neurotoxin and Tetanus Toxin , pp. 319-365
    • Notormans, S.1    Nagel, J.2
  • 6
    • 0000038294 scopus 로고
    • Bacterial toxin
    • Hardegree, M. C. and Tu, A. T. (eds.) Marcel Dekker, New York
    • Sakaguchi, G., Ohishi, I., and Kozaki, S. (1988) Bacterial toxin, in Handbook of Natural Toxin, Hardegree, M. C. and Tu, A. T. (eds.) pp. 191-216, Marcel Dekker, New York.
    • (1988) Handbook of Natural Toxin , pp. 191-216
    • Sakaguchi, G.1    Ohishi, I.2    Kozaki, S.3
  • 7
    • 0029439191 scopus 로고
    • Real-time detection and quantification of DNA hybridization by an optical biosensor
    • Watts, H. J., Yeung, D., and Parkes, H. (1995) Real-time detection and quantification of DNA hybridization by an optical biosensor. Anal. Chem. 67, 4283-4289.
    • (1995) Anal. Chem. , vol.67 , pp. 4283-4289
    • Watts, H.J.1    Yeung, D.2    Parkes, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.