메뉴 건너뛰기




Volumn 29, Issue 1, 1998, Pages 47-63

Thermal and daylighting performance of an automated venetian blind and lighting system in a full-scale private office

Author keywords

Daylighting; Energy efficiency; Lighting; Thermal measurements; Windows

Indexed keywords

COOLING; DAYLIGHTING; ENERGY EFFICIENCY; INTERIORS (BUILDING); OPTIMIZATION; THERMAL VARIABLES MEASUREMENT;

EID: 0032305060     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0378-7788(98)00035-8     Document Type: Article
Times cited : (153)

References (12)
  • 1
    • 0025554759 scopus 로고
    • Experimental study of full-size automated venetian blind windows
    • S. Rheault, E. Bilgen, Experimental study of full-size automated venetian blind windows, Solar Energy 44 (3) (1990) 157-160.
    • (1990) Solar Energy , vol.44 , Issue.3 , pp. 157-160
    • Rheault, S.1    Bilgen, E.2
  • 3
    • 0041520404 scopus 로고
    • Performance assessment on a smart system for the combined control of natural and artificial lighting
    • Third European Conference on Architecture, Florence, Italy, 17-21 May
    • F. Aleo, S. Sciuto, Performance assessment on a smart system for the combined control of natural and artificial lighting, Proc. Solar Energy in Architecture and Urban Planning, Third European Conference on Architecture, Florence, Italy, 17-21 May 1993.
    • (1993) Proc. Solar Energy in Architecture and Urban Planning
    • Aleo, F.1    Sciuto, S.2
  • 4
    • 85103065269 scopus 로고    scopus 로고
    • Overall performance of an automated venetian blind/electric lighting system in a full-scale office environment
    • 7-11 December 1998 in Clearwater Beach, FL and to be published in the Proceedings
    • E.S. Lee, D.L. DiBartolomeo, E. Vine, S.E. Selkowitz, 1998, Overall performance of an automated venetian blind/electric lighting system in a full-scale office environment, To be presented at the Thermal Performance of the Exterior Envelopes of Buildings VII, 7-11 December 1998 in Clearwater Beach, FL and to be published in the Proceedings.
    • (1998) Thermal Performance of the Exterior Envelopes of Buildings VII
    • Lee, E.S.1    DiBartolomeo, D.L.2    Vine, E.3    Selkowitz, S.E.4
  • 6
    • 0003819709 scopus 로고
    • Impact assessment and performance targets for lighting and envelope systems
    • Lawrence Berkeley National Laboratory, Berkeley, CA
    • R. Sullivan, E.S. Lee, S.E. Selkowitz, Impact assessment and performance targets for lighting and envelope systems, LBNL Report 33075, Lawrence Berkeley National Laboratory, Berkeley, CA, 1992.
    • (1992) LBNL Report 33075
    • Sullivan, R.1    Lee, E.S.2    Selkowitz, S.E.3
  • 7
    • 0029212466 scopus 로고
    • The design and evaluation of integrated envelope and lighting control strategies for commercial building
    • E.S. Lee, S. Selkowitz, The design and evaluation of integrated envelope and lighting control strategies for commercial building, ASHRAE Trans. 101 (1) (1995) 326-342.
    • (1995) ASHRAE Trans. , vol.101 , Issue.1 , pp. 326-342
    • Lee, E.S.1    Selkowitz, S.2
  • 9
    • 0031539248 scopus 로고    scopus 로고
    • Developing a dynamic envelope/lighting control system with field measurements
    • D.L. DiBartolomeo, E.S. Lee, F.M. Rubinstein, S.E. Selkowitz, Developing a dynamic envelope/lighting control system with field measurements, J. Illum. Eng. Soc. 26 (1) (1997) 146-164.
    • (1997) J. Illum. Eng. Soc. , vol.26 , Issue.1 , pp. 146-164
    • DiBartolomeo, D.L.1    Lee, E.S.2    Rubinstein, F.M.3    Selkowitz, S.E.4
  • 12
    • 0030646602 scopus 로고    scopus 로고
    • Solar heat gain coefficient of complex fenestrations with a venetian blind for differing slat tilt angles
    • J.H. Klems, J.L. Warner, Solar heat gain coefficient of complex fenestrations with a venetian blind for differing slat tilt angles, ASHRAE Trans. 103 (1) (1997) .
    • (1997) ASHRAE Trans. , vol.103 , Issue.1
    • Klems, J.H.1    Warner, J.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.