메뉴 건너뛰기




Volumn 39, Issue , 1998, Pages 347-348

An apparatus for studying wear damage in UHMWPE: Description and initial test results

Author keywords

[No Author keywords available]

Indexed keywords

FINITE ELEMENT METHOD; IMPLANTS (SURGICAL); KINEMATICS; LOADS (FORCES); ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS;

EID: 0032296923     PISSN: 10716947     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Article
Times cited : (5)

References (9)
  • 1
    • 0023007566 scopus 로고
    • The Effect of Conformity, Thickness, and Material on Stresses in UHMWPE Components for Total Joint Replacement
    • Bartel, D.L., Bicknell, V.L., and Wright, T.M., 1986, "The Effect of Conformity, Thickness, and Material on Stresses in UHMWPE Components for Total Joint Replacement,". J Bone Jt Surg 68A:1041-1051.
    • (1986) J Bone Jt Surg , vol.68 A , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 2
    • 11644283123 scopus 로고    scopus 로고
    • Is Oxidation of UHMWPE the Main Cause of Delamination Wear in Total Knee Replacement
    • Bell, C.J., Simmons, J., King, P., Walker, P.S., and Blunn, G.W., 1997, "Is Oxidation of UHMWPE the Main Cause of Delamination Wear in Total Knee Replacement," Trans Ortho Res Soc 22:96.
    • (1997) Trans Ortho Res Soc , vol.22 , pp. 96
    • Bell, C.J.1    Simmons, J.2    King, P.3    Walker, P.S.4    Blunn, G.W.5
  • 3
    • 0001157692 scopus 로고    scopus 로고
    • Global Reference UHMWPE: Characterization and Comparison to Conventional UHMWPE
    • Bennet, A.P., Wright, T.M., and Li, S., 1996, "Global Reference UHMWPE: Characterization and Comparison to Conventional UHMWPE. Trans Ortho Res Soc 21:472.
    • (1996) Trans Ortho Res Soc , vol.21 , pp. 472
    • Bennet, A.P.1    Wright, T.M.2    Li, S.3
  • 4
    • 11644266305 scopus 로고    scopus 로고
    • Controlling the Physical properties of Molded UHMWPE Through Predictable Interactions between Processing Variables
    • Duus, L.C., Santner, T., Williams, B.J., and Li, S., 1998, "Controlling the Physical properties of Molded UHMWPE Through Predictable Interactions Between Processing Variables," Trans Ortho Res Soc 23:367.
    • (1998) Trans Ortho Res Soc , vol.23 , pp. 367
    • Duus, L.C.1    Santner, T.2    Williams, B.J.3    Li, S.4
  • 6
    • 0344278169 scopus 로고    scopus 로고
    • Surface Residual Tensile Stress after Cyclic Loading of UHMWPE by a Rigid Indenter
    • Estupiñán, J.A., Bartel, D.L., and Wright, T.M., 1996, :Surface Residual Tensile Stress After Cyclic Loading of UHMWPE by a Rigid Indenter," Trans Ortho Res Soc 21:48.
    • (1996) Trans Ortho Res Soc , vol.21 , pp. 48
    • Estupiñán, J.A.1    Bartel, D.L.2    Wright, T.M.3
  • 7
    • 0000414877 scopus 로고    scopus 로고
    • Kinetics, Chemistry, and Calibration of UHMWPE Accelerated Aging Methods
    • Furman, B.D., Lelas, J., McNulty, D, Smith, T., and Li, S., 1998, "Kinetics, Chemistry, and Calibration of UHMWPE Accelerated Aging Methods," Trans Ortho Res Soc 23:102.
    • (1998) Trans Ortho Res Soc , vol.23 , pp. 102
    • Furman, B.D.1    Lelas, J.2    McNulty, D.3    Smith, T.4    Li, S.5
  • 8
    • 0030668935 scopus 로고    scopus 로고
    • Factors Affecting Aseptic failure of Fixation after Primary Total Hip Arthroplasty
    • Kobayashi, S., Takaoka, K., Saito, N., Hisa, K., 1997, "Factors Affecting Aseptic failure of Fixation after Primary Total Hip Arthroplasty," J Bone Jt Surg 79A:1618-1627.
    • (1997) J Bone Jt Surg , vol.79 A , pp. 1618-1627
    • Kobayashi, S.1    Takaoka, K.2    Saito, N.3    Hisa, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.