메뉴 건너뛰기




Volumn 9, Issue 3, 1998, Pages 27-39

Extra large orifice (ELO) sprinklers: An overview of full-scale fire test performance

Author keywords

[No Author keywords available]

Indexed keywords

MATHEMATICAL MODELS; ORIFICES;

EID: 0032289785     PISSN: 10423915     EISSN: 1532172X     Source Type: Journal    
DOI: 10.1177/104239159800900303     Document Type: Article
Times cited : (2)

References (13)
  • 3
    • 79957606662 scopus 로고
    • Factory Mutual Research Corporation, ", (Proposed), 02062, Factory Mutual Research Corporation, Norwood, MA
    • Factory Mutual Research Corporation, Approval Standard, Class Number 2009, "Extra Large Orifice (ELO) Sprinklers", 1994 (Proposed), Factory Mutual Research Corporation, Norwood, MA 02062.
    • (1994) Approval Standard, Class Number 2009, "Extra Large Orifice (ELO) Sprinklers
  • 4
    • 79957605104 scopus 로고
    • ", 02062, Factory Mutual Research Corporation, Norwood, MA, Factory Mutual Engineering Corp, D.S. 2-8N, "Installation of Sprinkler Systems", 1989 and D.S. 8-9, "Storage of Class 1, 2, 3, 4 and Plastic Commodities
    • Factory Mutual Engineering Corp., Loss Prevention Data Sheets, D.S. 2-8N, "Installation of Sprinkler Systems", 1989 and D.S. 8-9, "Storage of Class 1, 2, 3, 4 and Plastic Commodities", 1995, Factory Mutual Research Corporation, Norwood, MA 02062.
    • (1995) Loss Prevention Data Sheets
  • 5
    • 0343287308 scopus 로고    scopus 로고
    • National Fire Protection Association, 02269, National Fire Protection Association, Quincy, MA, NFPA 231-1995 "Standard for General Storage" and NFPA 231C-1995 "Standard for Rack Storage of Materials", including Tentative Interim Amendments
    • National Fire Protection Association, National Fire Codes, NFPA 231-1995 "Standard for General Storage" and NFPA 231C-1995 "Standard for Rack Storage of Materials", including Tentative Interim Amendments, National Fire Protection Association, Quincy, MA 02269.
    • National Fire Codes
  • 6
    • 79957609132 scopus 로고
    • ", prepared for 02269 and 02062, May, National Fire Protection Research Foundation, Quincy, MA, Factory Mutual Research Corporation, Norwood MA, Factory Mutual Research Corporation Technical Report FMRC J.I. OM2R5.RR/OMOJ7.RR
    • Chicarello, P.J., Troup, J.M.A. and Dean, R.K., "Large-Scale Fire Test Evaluation of Early Suppression Fast Response Automatic Sprinklers", Factory Mutual Research Corporation Technical Report FMRC J.I. OM2R5.RR/OMOJ7.RR, prepared for National Fire Protection Research Foundation, Quincy, MA 02269 and Factory Mutual Research Corporation, Norwood MA 02062, May 1986.
    • (1986) Large-Scale Fire Test Evaluation of Early Suppression Fast Response Automatic Sprinklers"
    • Chicarello, P.J.1    Troup, J.M.A.2    Dean, R.K.3
  • 7
    • 79957581891 scopus 로고
    • Four-Tier Array Rack Storage Fire Tests with Fast Response Prototype Sprinklers
    • "", The Proceedings of the Second International Symposium of Fire Safety Science
    • Kung, H-C., Yu, H-Z., Brown, W.R. and Vincent, B.G., "Four-Tier Array Rack Storage Fire Tests with Fast Response Prototype Sprinklers", The Proceedings of the Second International Symposium of Fire Safety Science, 1988.
    • (1988)
    • Kung, H.-C.1    Yu, H.-Z.2    Brown, W.R.3    Vincent, B.G.4
  • 8
    • 79957604844 scopus 로고
    • Factory Mutual Research Corporation, Prepared for 6, April, Central Sprinkler Company, Lansdale, PA, FMRC J.I. 0X1A7.AH
    • Factory Mutual Research Corporation, Approval Report Model ELO-231 Upright Sprinkler, FMRC J.I. 0X1A7.AH, Prepared for Central Sprinkler Company, Lansdale, PA 19446, April 1993.
    • (1944) Approval Report Model ELO-231 Upright Sprinkler
  • 9
    • 79957604844 scopus 로고
    • Factory Mutual Research Corporation, Prepared for 6, May, Central Sprinkler Company, Lansdale, PA, FMRC J.I. 1X9A1.AH
    • Factory Mutual Research Corporation, Approval Report Model ELO-231 Pendent Sprinkler, FMRC J.I. 1X9A1.AH, Prepared for Central Sprinkler Company, Lansdale, PA 19446, May 1994.
    • (1944) Approval Report Model ELO-231 Pendent Sprinkler
  • 10
    • 79957603840 scopus 로고
    • Factory Mutual Research Corporation, Prepared for 10552, April, Reliable Automatic Sprinkler Company, Mount Vernon, NY, FMRC J.I. 0X7A1.AH
    • Factory Mutual Research Corporation, Approval Report Model G-XLO Upright Sprinkler, FMRC J.I. 0X7A1.AH, Prepared for Reliable Automatic Sprinkler Company, Mount Vernon, NY 10552, April 1994.
    • (1994) Approval Report Model G-XLO Upright Sprinkler
  • 11
    • 79957603840 scopus 로고
    • Factory Mutual Research Corporation, Prepared for 02910, September, Grinnell Corporation, Cranston, RI, FMRC J.I. 0X4A5.AH
    • Factory Mutual Research Corporation, Approval Report Model F892 Upright Sprinkler, FMRC J.I. 0X4A5.AH, Prepared for Grinnell Corporation, Cranston, RI 02910, September 1994.
    • (1994) Approval Report Model F892 Upright Sprinkler
  • 12
    • 79957606403 scopus 로고    scopus 로고
    • Factory Mutual Research Corporation, Prepared for 48658, January, Globe Fire Sprinkler Corporation, Standish, MI, FMRC J.I. 1Y9A5.AH
    • Factory Mutual Research Corporation, Approval Report Model JN Upright Sprinkler, FMRC J.I. 1Y9A5.AH, Prepared for Globe Fire Sprinkler Corporation, Standish, MI 48658, January 1997.
    • (1997) Approval Report Model JN Upright Sprinkler
  • 13
    • 79957606403 scopus 로고    scopus 로고
    • Factory Mutual Research Corporation, Prepared for 49058, January, The Viking Corporation, Hastings, MI, FMRC J.I. 2X0A9.AH
    • Factory Mutual Research Corporation, Approval Report Model M Upright Sprinkler, FMRC J.I. 2X0A9.AH, Prepared for The Viking Corporation, Hastings, MI 49058, January 1997.
    • (1997) Approval Report Model M Upright Sprinkler