메뉴 건너뛰기




Volumn 33, Issue 6, 1998, Pages 329-332

Abscess formation within a synthetic hydroxyapatite orbital implant

Author keywords

Hydroxyapatite; Orbital implant

Indexed keywords

HYDROXYAPATITE;

EID: 0032287085     PISSN: 00084182     EISSN: 17153360     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (18)

References (20)
  • 1
    • 0029025255 scopus 로고
    • Current techniques of enucleation: A survey of 5,439 intraorbital implants and a review of the literature
    • Hornblass A, Biesman BS, Eviatar JA. Current techniques of enucleation: a survey of 5,439 intraorbital implants and a review of the literature. Ophthalmic Plast Reconstr Surg 1995;11:77-88.
    • (1995) Ophthalmic Plast Reconstr Surg , vol.11 , pp. 77-88
    • Hornblass, A.1    Biesman, B.S.2    Eviatar, J.A.3
  • 2
    • 0026651109 scopus 로고
    • Tissue breakdown and exposure associated with orbital hydroxyapatite implants
    • Buettner H, Bartley GB. Tissue breakdown and exposure associated with orbital hydroxyapatite implants. Am J Ophthalmol 1992;113:669-73.
    • (1992) Am J Ophthalmol , vol.113 , pp. 669-673
    • Buettner, H.1    Bartley, G.B.2
  • 3
    • 0026647376 scopus 로고
    • Exposed hydroxyapatite orbital implants: Report of six cases
    • Goldberg RA, Holds JB, Ebrahimpour J. Exposed hydroxyapatite orbital implants: report of six cases. Ophthalmology 1992;99:831-6.
    • (1992) Ophthalmology , vol.99 , pp. 831-836
    • Goldberg, R.A.1    Holds, J.B.2    Ebrahimpour, J.3
  • 4
    • 0027235625 scopus 로고
    • Exposure rate of hydroxyapatite spheres in the anophthalmic socket: Histopathologic correlation and comparison with silicone sphere implants
    • Nunery WR, Heinz GW, Bonnin JM, Martin RT, Cepela MA. Exposure rate of hydroxyapatite spheres in the anophthalmic socket: histopathologic correlation and comparison with silicone sphere implants. Ophthalmic Plast Reconstr Surg 1993;9:96-104.
    • (1993) Ophthalmic Plast Reconstr Surg , vol.9 , pp. 96-104
    • Nunery, W.R.1    Heinz, G.W.2    Bonnin, J.M.3    Martin, R.T.4    Cepela, M.A.5
  • 5
    • 0028020803 scopus 로고
    • Hydroxyapatite orbital implant abscess: Histopathologic correlation of an infected implant following evisceration
    • Ainbinder DJ, Haik BG, Tellado M. Hydroxyapatite orbital implant abscess: histopathologic correlation of an infected implant following evisceration. Ophthalmic Plast Reconstr Surg 1994;10:267-70.
    • (1994) Ophthalmic Plast Reconstr Surg , vol.10 , pp. 267-270
    • Ainbinder, D.J.1    Haik, B.G.2    Tellado, M.3
  • 6
    • 0029807024 scopus 로고    scopus 로고
    • Abscessed hydroxyapatite orbital implants: A report of two cases
    • Jordan DR, Brownstein S, Jolly SS. Abscessed hydroxyapatite orbital implants: a report of two cases. Ophthalmology 1996;103:1784-7.
    • (1996) Ophthalmology , vol.103 , pp. 1784-1787
    • Jordan, D.R.1    Brownstein, S.2    Jolly, S.S.3
  • 8
    • 0030068982 scopus 로고    scopus 로고
    • Prevention and management of complications associated with the hydroxyapatite implant
    • Kaltreider SA, Newman SA. Prevention and management of complications associated with the hydroxyapatite implant. Ophthalmic Plast Reconstr Surg 1996;12:18-31.
    • (1996) Ophthalmic Plast Reconstr Surg , vol.12 , pp. 18-31
    • Kaltreider, S.A.1    Newman, S.A.2
  • 11
    • 0027932582 scopus 로고
    • Problems with the hydroxyapatite orbital implant: Experience with 250 consecutive cases
    • Shields CL, Shields JA, De Potter P, Singh AD. Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases. Br J Ophthalmol 1994;78:702-6.
    • (1994) Br J Ophthalmol , vol.78 , pp. 702-706
    • Shields, C.L.1    Shields, J.A.2    De Potter, P.3    Singh, A.D.4
  • 13
    • 0032432030 scopus 로고    scopus 로고
    • Scanning electron microscopic examination of porous orbital implants
    • Mawn LA, Jordan DR, Gilberg S. Scanning electron microscopic examination of porous orbital implants. Can J Ophthalmol 1998;33:203-9.
    • (1998) Can J Ophthalmol , vol.33 , pp. 203-209
    • Mawn, L.A.1    Jordan, D.R.2    Gilberg, S.3
  • 14
    • 0026093148 scopus 로고
    • Histopathologic evidence of fibrovascular ingrowth four weeks after placement of the hydroxyapatite orbital implant
    • Shields CL, Shields JA, Eagle RC Jr, De Potter P. Histopathologic evidence of fibrovascular ingrowth four weeks after placement of the hydroxyapatite orbital implant. Am J Ophthalmol 1991;111:363-6.
    • (1991) Am J Ophthalmol , vol.111 , pp. 363-366
    • Shields, C.L.1    Shields, J.A.2    Eagle Jr., R.C.3    De Potter, P.4
  • 16
    • 0025976934 scopus 로고
    • Coralline hydroxyapatite as an ocular implant
    • Dutton JJ. Coralline hydroxyapatite as an ocular implant. Ophthalmology 1991;98:370-7.
    • (1991) Ophthalmology , vol.98 , pp. 370-377
    • Dutton, J.J.1
  • 17
    • 0026734386 scopus 로고
    • Rate of vascularization of coralline hydroxyapatite ocular implants
    • Ferrone PJ, Dutton JJ. Rate of vascularization of coralline hydroxyapatite ocular implants. Ophthalmology 1992;99: 376-9.
    • (1992) Ophthalmology , vol.99 , pp. 376-379
    • Ferrone, P.J.1    Dutton, J.J.2
  • 18
    • 0026749245 scopus 로고
    • Role of magnetic resonance imaging in the evaluation of the hydroxyapatite orbital implant
    • De Potter P, Shields CL, Shields JA, Flanders AE, Rao VM. Role of magnetic resonance imaging in the evaluation of the hydroxyapatite orbital implant. Ophthalmology 1992;99:824-30.
    • (1992) Ophthalmology , vol.99 , pp. 824-830
    • De Potter, P.1    Shields, C.L.2    Shields, J.A.3    Flanders, A.E.4    Rao, V.M.5
  • 20
    • 0028944557 scopus 로고
    • Gadolinium-enhanced magnetic resonance imaging assessment of hydroxyapatite orbital implants
    • Spirnak JP, Nieves N, Hollsten DA, White WC, Betz TA. Gadolinium-enhanced magnetic resonance imaging assessment of hydroxyapatite orbital implants. Am J Ophthalmol 1995;119:431-40.
    • (1995) Am J Ophthalmol , vol.119 , pp. 431-440
    • Spirnak, J.P.1    Nieves, N.2    Hollsten, D.A.3    White, W.C.4    Betz, T.A.5