메뉴 건너뛰기




Volumn 2, Issue 6, 1998, Pages 351-361

Enzyme-Based Electrodes for Environmental Monitoring Applications

Author keywords

Biosensor; Field testing; Phenolic compounds; Phenols; Tyrosinase

Indexed keywords


EID: 0032261862     PISSN: 1086900X     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1520-6521(1998)2:6<351::AID-FACT5>3.0.CO;2-R     Document Type: Article
Times cited : (17)

References (25)
  • 1
    • 0029843508 scopus 로고    scopus 로고
    • Environmental biosensors: A status report
    • Rogers K, Gerlach C. Environmental biosensors: A status report. Environ Sci Technol 1996;30, 486A-491A.
    • (1996) Environ Sci Technol , vol.30
    • Rogers, K.1    Gerlach, C.2
  • 2
    • 0008011094 scopus 로고    scopus 로고
    • Introduction to amperometric biosensor configurations
    • Kissinger PT. Introduction to amperometric biosensor configurations. Current Contents 1997;16:101-103.
    • (1997) Current Contents , vol.16 , pp. 101-103
    • Kissinger, P.T.1
  • 3
    • 0029044840 scopus 로고
    • Biosensors for environmental applications
    • Rogers K. Biosensors for environmental applications Biosensors Bioelectron 1995;10:553-541.
    • (1995) Biosensors Bioelectron , vol.10 , pp. 553-1541
    • Rogers, K.1
  • 4
    • 0029182252 scopus 로고
    • Hand-held potentiometric stripping analyzer for field screening of toxic metals
    • New Orleans
    • Schmidt J, Lekas E, Diberardino C. Hand-held potentiometric stripping analyzer for field screening of toxic metals. In: Proceedings ISA95. New Orleans, 1995.
    • (1995) Proceedings ISA95
    • Schmidt, J.1    Lekas, E.2    Diberardino, C.3
  • 5
    • 0030808758 scopus 로고    scopus 로고
    • Flow injection detector incor porating a screen-printed disposable amperometric biosensor for monitoring organophosphate pesticides
    • Rippeth J, Gibson T, Hart J, Nelson G. Flow injection detector incor porating a screen-printed disposable amperometric biosensor for monitoring organophosphate pesticides. Analyst 1997;122:1425-1429.
    • (1997) Analyst , vol.122 , pp. 1425-1429
    • Rippeth, J.1    Gibson, T.2    Hart, J.3    Nelson, G.4
  • 6
    • 0026458516 scopus 로고
    • Detection of organophosphate and carbamate pesticides using disposable biosensors based on chemically modified electrodes and immobilized cholinesterase
    • Skladal P. Detection of organophosphate and carbamate pesticides using disposable biosensors based on chemically modified electrodes and immobilized cholinesterase. Anal Chim Acta 1992;269:281.
    • (1992) Anal Chim Acta , vol.269 , pp. 281
    • Skladal, P.1
  • 7
    • 0029079947 scopus 로고
    • A biosensor as warning device for the detection of cyanide, chlorophenols, atrazine, and carbamate pesticides
    • Besombes J, Cosnier S, Labbe P, Reverdy G. A biosensor as warning device for the detection of cyanide, chlorophenols, atrazine, and carbamate pesticides. Anal Chim Acta 1995;311:255.
    • (1995) Anal Chim Acta , vol.311 , pp. 255
    • Besombes, J.1    Cosnier, S.2    Labbe, P.3    Reverdy, G.4
  • 8
    • 0030296361 scopus 로고    scopus 로고
    • Screen-printed tyrosinase-containing electrodes for the biosensing of enzyme inhibitors
    • Wang J, Nascimento VB, Kane SA, Rogers K, Smyth MR, Angnes I. Screen-printed tyrosinase-containing electrodes for the biosensing of enzyme inhibitors. Talanta 1996;43:1903.
    • (1996) Talanta , vol.43 , pp. 1903
    • Wang, J.1    Nascimento, V.B.2    Kane, S.A.3    Rogers, K.4    Smyth, M.R.5    Angnes, I.6
  • 10
    • 0032522988 scopus 로고    scopus 로고
    • Construction and characterization of nitrate reductase-based amperometric electrodes and nitrate assay of fertilizers and drinking water
    • Glazier SA, Campbell ER, Campbell WH. Construction and characterization of nitrate reductase-based amperometric electrodes and nitrate assay of fertilizers and drinking water. Anal Chem 1998;70.1511
    • (1998) Anal Chem , vol.70 , pp. 1511
    • Glazier, S.A.1    Campbell, E.R.2    Campbell, W.H.3
  • 15
    • 0028388165 scopus 로고
    • Amperometric biosensor for phenols based on a tyrosinase-graphite-epoxy biocomposite
    • Wang J, Fang L, Lopez D. Amperometric biosensor for phenols based on a tyrosinase-graphite-epoxy biocomposite. Analyst 1994;119:455-458.
    • (1994) Analyst , vol.119 , pp. 455-458
    • Wang, J.1    Fang, L.2    Lopez, D.3
  • 16
    • 0029209486 scopus 로고
    • Methyl- phenazonium-modified enzyme sensor based on polymer thick films for subnanomolar detection of phenols
    • Kotte H, Grundig B, Vorlop K, Strehlitz B, Stottmeister U. Methyl- phenazonium-modified enzyme sensor based on polymer thick films for subnanomolar detection of phenols. Anal Chem 1995;67:65-70.
    • (1995) Anal Chem , vol.67 , pp. 65-70
    • Kotte, H.1    Grundig, B.2    Vorlop, K.3    Strehlitz, B.4    Stottmeister, U.5
  • 17
    • 0029115156 scopus 로고
    • Investigation of the effects of polar organic solvents on the activity of tyrosinase entrapped in a poly(ester-sulfonic acid) polymer
    • Iwuoha EI, Adeyoju O, Dempsey E, Liu J, Wang J. Investigation of the effects of polar organic solvents on the activity of tyrosinase entrapped in a poly(ester-sulfonic acid) polymer Biosensors Bioelectron 1995;10:66-667.
    • (1995) Biosensors Bioelectron , vol.10 , pp. 66-667
    • Iwuoha, E.I.1    Adeyoju, O.2    Dempsey, E.3    Liu, J.4    Wang, J.5
  • 18
    • 0029110752 scopus 로고
    • Microfabricated phenol biosensors based on screen printing of tyrosinase containing carbon ink
    • Wang J, Chen Q. Microfabricated phenol biosensors based on screen printing of tyrosinase containing carbon ink. Anal Lett 1995;28:1131-1142
    • (1995) Anal Lett , vol.28 , pp. 1131-1142
    • Wang, J.1    Chen, Q.2
  • 19
    • 0027325001 scopus 로고
    • Preservation of shelf life of enzyme based analytical systems using a combination of sugars, sugar alcohols and cationic polymers or zinc ions
    • Gibson TD, Hulbert JN, Woodward JR. Preservation of shelf life of enzyme based analytical systems using a combination of sugars, sugar alcohols and cationic polymers or zinc ions. Anal Chim Acta 1993;279:185-192.
    • (1993) Anal Chim Acta , vol.279 , pp. 185-192
    • Gibson, T.D.1    Hulbert, J.N.2    Woodward, J.R.3
  • 20
    • 0029931487 scopus 로고    scopus 로고
    • Stabilization of lactate oxidase in screenprinted enzyme electrodes
    • Hart AL, Cox J, Janssen D. Stabilization of lactate oxidase in screenprinted enzyme electrodes. Biosensors Bioelectron 1996;11:833-837.
    • (1996) Biosensors Bioelectron , vol.11 , pp. 833-837
    • Hart, A.L.1    Cox, J.2    Janssen, D.3
  • 21
    • 2742614856 scopus 로고    scopus 로고
    • Priddy R, Schmidt J. Disposable sensor for metal analysis. U. S. Patent 5,554,268, 1996
    • Priddy R, Schmidt J. Disposable sensor for metal analysis. U. S. Patent 5,554,268, 1996.
  • 23
    • 0003419429 scopus 로고
    • Methods for chemical analysis of water and wastewater
    • available from the National Technical Information Service, AD Number PB84-128677
    • Kopp JR, McKee JD. Methods for chemical analysis of water and wastewater. U. S. Environmental Protection Agency Report EPA-800-4-79-020, available from the National Technical Information Service, AD Number PB84-128677, 1983, pp. 497-510.
    • (1983) U. S. Environmental Protection Agency Report , vol.EPA-800-4-79-020 , pp. 497-510
    • Kopp, J.R.1    McKee, J.D.2
  • 25
    • 0019300258 scopus 로고
    • Guidelines for data acquisition and data quality evaluation in environmental chemistry
    • Guidelines for data acquisition and data quality evaluation in environmental chemistry. Anal Chem 52, 1980:2242.
    • (1980) Anal Chem , vol.52 , pp. 2242


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.