메뉴 건너뛰기




Volumn 10, Issue 2, 1998, Pages 91-95

Diffuse reflectance laser-flash photolytic study of aromatic ketones within calixarene solid matrices

Author keywords

Aromatic ketones; Calixarenes; Laser flash photolysis

Indexed keywords


EID: 0032259013     PISSN: 10610278     EISSN: None     Source Type: Journal    
DOI: 10.1080/10610279808055399     Document Type: Article
Times cited : (10)

References (14)
  • 5
    • 0001142320 scopus 로고
    • Benzophenone (BDH), xanthone, and p-t-butylcalix[6]arene (Aldrich) were recrystallized before use. Hexa-t-butyl-37,38,39,40,41,42-hexaethoxycalix[6]arene was prepared according to: Gutsche, C. D. and Lin, L.-G. (1986). Tetrahedron, 42, 1633.
    • (1986) Tetrahedron , vol.42 , pp. 1633
    • Gutsche, C.D.1    Lin, L.-G.2
  • 6
    • 0031591903 scopus 로고    scopus 로고
    • Ketone/calixarene solid samples were prepared by slow solvent evaporation of solutions, in either chloroform or dichloromethane (Omnisolv), containing the corresponding guest compound and calixarene (in 1:1 or 1:2 molar ratio). Laser experiments were carried out using a Nd/YAG laser (Continuum, Surelite I-10) operated at 355 nm (4-6ns pulses, < 50mJ/pulse) for excitation. Solid samples, contained in quartz cells constructed of 3 mm × 7 mm Suprasil tubing, were shaken after every laser pulse to ensure the irradiation of fresh portions of sample by each laser pulse. The time-resolved diffuse reflectance laser-flash photolysis system is controlled by a Power Mac 7100/80 computer running LabVIEVV 3.1.1 software from National Instruments. Further details on this system are reported elsewhere [Barra, M. and Agha, K. A. (1997). J. Photochem. Photobiol; A: Chem., 109, 293]. All measurements were done at room temperature.
    • (1997) J. Photochem. Photobiol; A: Chem. , vol.109 , pp. 293
    • Barra, M.1    Agha, K.A.2
  • 11
    • 11644310469 scopus 로고    scopus 로고
    • note
    • Steady-state irradiations were performed in a Rayonet photoreactor equipped with RPR-3500 lamps from the Southern New England Ultraviolet Co. The samples were contained in quartz cells of the same type used for laser experiments, and were shaken regularly and rotated with a "merry-go-round" apparatus.
  • 12
    • 11644309591 scopus 로고    scopus 로고
    • note
    • Fittings of triplet decay traces were carried out by using the general curve fitting procedure of Kaleidagraph 3.0.5 software from Synergy Software.
  • 14
    • 11644267936 scopus 로고    scopus 로고
    • note
    • Spectra were recorded at room temperature with a Bruker AMX-500 instrument.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.