메뉴 건너뛰기




Volumn 1998, Issue SUPPL. 71, 1998, Pages 94-100

Morphological and Hemodynamic Evaluations by Means of Transcranial Power Doppler Imaging in Patients with Severe Head Injury

Author keywords

Severe head injury; Sonography; Transcranial power Doppler

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BLOOD FLOW VELOCITY; BRAIN; BRAIN CONCUSSION; BRAIN HEMORRHAGE; BRAIN INJURY; CHILD; DOPPLER ECHOGRAPHY; ECHOGRAPHY; FEMALE; HEMODYNAMICS; HUMAN; INSTRUMENTATION; INTENSIVE CARE UNIT; MALE; MIDDLE AGED; MONITORING; PATHOPHYSIOLOGY; PHYSIOLOGY; VASCULARIZATION;

EID: 0032239489     PISSN: 00651419     EISSN: None     Source Type: Book Series    
DOI: 10.1007/978-3-7091-6475-4_29     Document Type: Article
Times cited : (7)

References (20)
  • 1
    • 0025327368 scopus 로고
    • Intraoperative ultrasound imaging of the entire brain through unilateral exploratory burr holes after severe head injury: Technical note
    • Andrews BT, Mampalam TJ, Omsberg E, Pitts LH (1990) Intraoperative ultrasound imaging of the entire brain through unilateral exploratory burr holes after severe head injury: technical note. Surg Neurol 33: 291-294
    • (1990) Surg Neurol , vol.33 , pp. 291-294
    • Andrews, B.T.1    Mampalam, T.J.2    Omsberg, E.3    Pitts, L.H.4
  • 3
    • 0026738089 scopus 로고
    • The significance of posttraumatic increase in cerebral blood flow velocity: A transcranial Doppler ultrasound study
    • Chan K-H, Dearden NM, Miller JD (1992) The significance of posttraumatic increase in cerebral blood flow velocity: a transcranial Doppler ultrasound study. Neurosurgery 30: 697-700
    • (1992) Neurosurgery , vol.30 , pp. 697-700
    • Chan, K.-H.1    Dearden, N.M.2    Miller, J.D.3
  • 4
    • 0022260296 scopus 로고
    • Measurement of blood flow by ultrasound: Accuracy and sources of error
    • Gill RW (1985) Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med Biol 11: 625-641
    • (1985) Ultrasound Med Biol , vol.11 , pp. 625-641
    • Gill, R.W.1
  • 5
    • 0029166390 scopus 로고
    • Quantitative investigation of in vitro flow using three-dimensional colour Doppler ultrasound
    • Guo Z, Moreau M, Rickey DW, Picot PA, Fenster A (1995) Quantitative investigation of in vitro flow using three-dimensional colour Doppler ultrasound. Ultrasound Med Biol 21: 807-816
    • (1995) Ultrasound Med Biol , vol.21 , pp. 807-816
    • Guo, Z.1    Moreau, M.2    Rickey, D.W.3    Picot, P.A.4    Fenster, A.5
  • 7
    • 0030000306 scopus 로고    scopus 로고
    • Power Doppler: An advance over colour Doppler for transcranial imaging?
    • Kenton AR, Martin PJ, Evans DH (1996) Power Doppler: an advance over colour Doppler for transcranial imaging? Ultrasound Med Biol 22: 313-317
    • (1996) Ultrasound Med Biol , vol.22 , pp. 313-317
    • Kenton, A.R.1    Martin, P.J.2    Evans, D.H.3
  • 8
    • 0024419182 scopus 로고
    • Cerebral vasospasm diagnosis by means of angiography and blood velocity measurements
    • Wien
    • Lindegaard K-L, Nornes H, Bakke SJ, Sorteberg W, Nakstad P (1989) Cerebral vasospasm diagnosis by means of angiography and blood velocity measurements. Acta Neurochir (Wien) 100: 12-24
    • (1989) Acta Neurochir , vol.100 , pp. 12-24
    • Lindegaard, K.-L.1    Nornes, H.2    Bakke, S.J.3    Sorteberg, W.4    Nakstad, P.5
  • 9
    • 0026795479 scopus 로고
    • Posttraumatic cerebral arterial spasm: Transcranial Doppler ultrasound, cerebral blood flow, and angiographic findings
    • Martin NA, Doberstein C, Zane C, Caron MJ, Thomas K, Becker DP (1992) Posttraumatic cerebral arterial spasm: transcranial Doppler ultrasound, cerebral blood flow, and angiographic findings. J Neurosurg 77: 575-583
    • (1992) J Neurosurg , vol.77 , pp. 575-583
    • Martin, N.A.1    Doberstein, C.2    Zane, C.3    Caron, M.J.4    Thomas, K.5    Becker, D.P.6
  • 10
    • 0007358852 scopus 로고
    • Carotid blood flow measurement by means of ultrasonic techniques: Limitations and clinical use
    • Hartmann A, Hoyer S (eds) Springer, Berlin Heidelberg New York Tokyo
    • Müller HR, Radue ER, Saia A, Pallotti C, Buser M (1985) Carotid blood flow measurement by means of ultrasonic techniques: limitations and clinical use. In: Hartmann A, Hoyer S (eds) Cerebral blood flow and metabolism measurement. Springer, Berlin Heidelberg New York Tokyo, pp 571-590
    • (1985) Cerebral Blood Flow and Metabolism Measurement , pp. 571-590
    • Müller, H.R.1    Radue, E.R.2    Saia, A.3    Pallotti, C.4    Buser, M.5
  • 11
    • 0027251497 scopus 로고
    • Morphometry of intraluminal side-to-side differences in human basal cerebral arteries
    • Piepgras A, Bise K, Schmiedekt P (1991) Morphometry of intraluminal side-to-side differences in human basal cerebral arteries. Ultrasound Med Biol 19: 193-195
    • (1991) Ultrasound Med Biol , vol.19 , pp. 193-195
    • Piepgras, A.1    Bise, K.2    Schmiedekt, P.3
  • 12
    • 0029883046 scopus 로고    scopus 로고
    • Elevated transcranial Doppler flow velocities after severe head injury: Cerebral vasospasm or hyperemia?
    • Rommer B, Bellner J, Kongstad P, Sjoholm H (1996) Elevated transcranial Doppler flow velocities after severe head injury: cerebral vasospasm or hyperemia? J Neurosurg 85: 90-97
    • (1996) J Neurosurg , vol.85 , pp. 90-97
    • Rommer, B.1    Bellner, J.2    Kongstad, P.3    Sjoholm, H.4
  • 13
    • 0028273083 scopus 로고
    • Power Doppler us: A potentially useful alternative to mean frequency - Based color Doppler US
    • Rubin JM, Bude RO, Carson PL, Bree RL, Adler RS (1994) Power Doppler us: a potentially useful alternative to mean frequency - based color Doppler US. Radiology 190: 853-856
    • (1994) Radiology , vol.190 , pp. 853-856
    • Rubin, J.M.1    Bude, R.O.2    Carson, P.L.3    Bree, R.L.4    Adler, R.S.5
  • 14
    • 0027538556 scopus 로고
    • Comparative study of transcranial color duplex sonography and transcranial Doppler sonography in adults
    • Schöning M, Buchholz R, Walter J (1993) Comparative study of transcranial color duplex sonography and transcranial Doppler sonography in adults. J Neurosurg 78: 776-784
    • (1993) J Neurosurg , vol.78 , pp. 776-784
    • Schöning, M.1    Buchholz, R.2    Walter, J.3
  • 15
    • 0028125804 scopus 로고
    • Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults
    • Schöning M, Walter J, Scheel P (1994) Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults. Stroke 25: 17-22
    • (1994) Stroke , vol.25 , pp. 17-22
    • Schöning, M.1    Walter, J.2    Scheel, P.3
  • 16
    • 0029966499 scopus 로고    scopus 로고
    • Color duplex measurement of cerebral blood flow volume: Intra- And interobserver reproducibility and habituation to serial measurements in normal subjects
    • Schöning, M, Scheel P (1996) Color duplex measurement of cerebral blood flow volume: intra- and interobserver reproducibility and habituation to serial measurements in normal subjects. J Cerebral Blood Flow Metabol 16: 523-531
    • (1996) J Cerebral Blood Flow Metabol , vol.16 , pp. 523-531
    • Schöning, M.1    Scheel, P.2
  • 17
    • 0027365729 scopus 로고
    • Transcranial color-coded duplex sonography of intracerebral hematomas in adults
    • Seidel G, Kaps M, Dorndorf W (1993) Transcranial color-coded duplex sonography of intracerebral hematomas in adults. Stroke 24: 1519-1527
    • (1993) Stroke , vol.24 , pp. 1519-1527
    • Seidel, G.1    Kaps, M.2    Dorndorf, W.3
  • 18
    • 0007442424 scopus 로고
    • Cerebral blood flow volume measurement by color Doppler ultrasound
    • Shiogai T, Tomita Y, Saito I (1994) Cerebral blood flow volume measurement by color Doppler ultrasound. Neurosonology 7: 115
    • (1994) Neurosonology , vol.7 , pp. 115
    • Shiogai, T.1    Tomita, Y.2    Saito, I.3
  • 19
    • 0007359405 scopus 로고
    • Comparative study of Doppler power imaging and color flow imaging: Detectability of intracranial vessels
    • Shiogai T, Yonamine Y, Tomita Y, Sato E, Hara M, Saito I (1995) Comparative study of Doppler power imaging and color flow imaging: detectability of intracranial vessels. J Neuroimaging 5 [Suppl 2]: S84
    • (1995) J Neuroimaging , vol.5 , Issue.2 SUPPL.
    • Shiogai, T.1    Yonamine, Y.2    Tomita, Y.3    Sato, E.4    Hara, M.5    Saito, I.6
  • 20
    • 0028355592 scopus 로고
    • Color Doppler ultrasound of changes in small vessel diameter and cerebral blood flow during acute anemia in the newborn lamb
    • Taylor GA, Hudak ML (1994) Color Doppler ultrasound of changes in small vessel diameter and cerebral blood flow during acute anemia in the newborn lamb. Invest Radiol 29: 188-194
    • (1994) Invest Radiol , vol.29 , pp. 188-194
    • Taylor, G.A.1    Hudak, M.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.