메뉴 건너뛰기




Volumn 17, Issue 11, 1998, Pages 683-686

Mirror image artifacts of color Doppler images causing misinterpretation in carotid artery stenoses

Author keywords

Artifacts, mirror image; Carotid artery; Color coded duplex sonography; Mirror image artifact; Stenosis, carotid artery

Indexed keywords

BLOOD VESSELS; COLOR IMAGE PROCESSING; DOPPLER EFFECT; IMAGE ANALYSIS; ULTRASONIC IMAGING;

EID: 0032213480     PISSN: 02784297     EISSN: None     Source Type: Journal    
DOI: 10.7863/jum.1998.17.11.683     Document Type: Article
Times cited : (23)

References (10)
  • 2
    • 0025016802 scopus 로고
    • Color and spectral Doppler mirror-image artifact of the subclavian artery
    • Reading DD, Charboneau JW, Allison JW, et al: Color and spectral Doppler mirror-image artifact of the subclavian artery. Radiology 174:41, 1990
    • (1990) Radiology , vol.174 , pp. 41
    • Reading, D.D.1    Charboneau, J.W.2    Allison, J.W.3
  • 4
    • 0025006923 scopus 로고
    • The carotid ghost: A color Doppler ultrasound duplication artifact
    • Middleton WD, Melson GL: The carotid ghost: A color Doppler ultrasound duplication artifact. J Ultrasound Med 9:487, 1990
    • (1990) J Ultrasound Med , vol.9 , pp. 487
    • Middleton, W.D.1    Melson, G.L.2
  • 5
  • 6
    • 3643135029 scopus 로고
    • Spiegelartefakte an Karotisstenosen. Eine Fehlermöglichkeit bei der farbkodierten Duplex sonographie
    • Arning C: Spiegelartefakte an Karotisstenosen. Eine Fehlermöglichkeit bei der farbkodierten Duplex sonographie (abstract). Ultraschall Med 16(Suppl 1):S4, 1995
    • (1995) Ultraschall Med , vol.16 , Issue.1 SUPPL.
    • Arning, C.1
  • 7
    • 3643063239 scopus 로고
    • Color flow imaging with a linear transducer
    • Nanda NC (Ed): Philadelphia, Lea & Febiger
    • Durell M, Mandell L: Color flow imaging with a linear transducer. In Nanda NC (Ed): Textbook of Color Doppler Echocardiography. Philadelphia, Lea & Febiger, 1989, p 64
    • (1989) Textbook of Color Doppler Echocardiography , pp. 64
    • Durell, M.1    Mandell, L.2
  • 8
    • 0030771132 scopus 로고    scopus 로고
    • Possible errors caused by artifacts in the Doppler color image
    • Arning C: Possible errors caused by artifacts in the Doppler color image. Ultraschall Med 18:105, 1997
    • (1997) Ultraschall Med , vol.18 , pp. 105
    • Arning, C.1
  • 9
    • 0028273083 scopus 로고
    • Power Doppler US: A potentially useful alternative to mean frequency-based color Doppler US
    • Rubin JM, Bude RO, Carson PL, et al: Power Doppler US: A potentially useful alternative to mean frequency-based color Doppler US. Radiology 190:853, 1994
    • (1994) Radiology , vol.190 , pp. 853
    • Rubin, J.M.1    Bude, R.O.2    Carson, P.L.3
  • 10
    • 3643133015 scopus 로고
    • Colour Doppler artefacts
    • Labs KH, Jäger KA, Fitzgerald DE, et al: (Eds): London, Edward Arnold
    • Woodcock JP: Colour Doppler artefacts. In Labs KH, Jäger KA, Fitzgerald DE, et al: (Eds): Diagnostic Vascular Ultrasound. London, Edward Arnold, 1992, p 154
    • (1992) Diagnostic Vascular Ultrasound , pp. 154
    • Woodcock, J.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.