메뉴 건너뛰기




Volumn 56, Issue 3, 1998, Pages 261-270

Evaluation of enhanced high-resolution laser Doppler imaging in an in vitro tube model with the aim of assessing blood flow in separate microvessels

Author keywords

Blood flow; Hamster cheek pouch; High resolution; Laser Doppler imaging; Microcirculation; Vessel

Indexed keywords

ARTICLE; BLOOD FLOW; BLOOD VESSEL DIAMETER; HAMSTER; HEMATOCRIT; LASER DOPPLER FLOWMETRY; MICROVASCULATURE; MODEL; NONHUMAN; OPTICAL RESOLUTION; PRIORITY JOURNAL; SIGNAL PROCESSING; TECHNIQUE;

EID: 0032213202     PISSN: 00262862     EISSN: None     Source Type: Journal    
DOI: 10.1006/mvre.1998.2095     Document Type: Article
Times cited : (25)

References (19)
  • 1
    • 0031249901 scopus 로고    scopus 로고
    • Higher order moment processing of laser Doppler perfusion signals
    • Arildsson M. L., Wårdell K., Nilsson G. E. Higher order moment processing of laser Doppler perfusion signals. J. Biomed. Opt. 2:1997;358-363.
    • (1997) J. Biomed. Opt. , vol.2 , pp. 358-363
    • Arildsson, M.L.1    Wårdell, K.2    Nilsson, G.E.3
  • 3
    • 0019583049 scopus 로고
    • Model for laser Doppler measurements of blood flow in tissue
    • Bonner R., Nossal R. Model for laser Doppler measurements of blood flow in tissue. Appl. Opt. 20:1981;2097-2107.
    • (1981) Appl. Opt. , vol.20 , pp. 2097-2107
    • Bonner, R.1    Nossal, R.2
  • 4
    • 0030630781 scopus 로고    scopus 로고
    • Correlation between laser Doppler perfusion monitoring and hematocrit in hamster cheek pouch microcirculation
    • Colantuoni A., Bertuglia S. Correlation between laser Doppler perfusion monitoring and hematocrit in hamster cheek pouch microcirculation. Int. J. Microcirc. Clin. Exp. 17:1997;33-40.
    • (1997) Int. J. Microcirc. Clin. Exp. , vol.17 , pp. 33-40
    • Colantuoni, A.1    Bertuglia, S.2
  • 6
    • 0031282240 scopus 로고    scopus 로고
    • Can blood flow in separate small tubes be quantitatively assessed by high-resolution laser Doppler imaging?
    • Lindén M. Can blood flow in separate small tubes be quantitatively assessed by high-resolution laser Doppler imaging? Med. Biol. Eng. Comput. 35:1997;575-580.
    • (1997) Med. Biol. Eng. Comput. , vol.35 , pp. 575-580
    • Lindén, M.1
  • 8
    • 0021461869 scopus 로고
    • Signal processor for laser Doppler tissue flowmeters
    • Nilsson G. E. Signal processor for laser Doppler tissue flowmeters. Med. Biol. Eng. Comput. 22:1984;343-348.
    • (1984) Med. Biol. Eng. Comput. , vol.22 , pp. 343-348
    • Nilsson, G.E.1
  • 9
    • 0019230971 scopus 로고
    • Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow
    • Nilsson G. E., Tenland T., Öberg P. Å. Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow. IEEE Trans. Biomed. Eng. 27:1980a;597-604.
    • (1980) IEEE Trans. Biomed. Eng. , vol.27 , pp. 597-604
    • Nilsson, G.E.1    Tenland, T.2    Öberg P., Å.3
  • 10
    • 0019225916 scopus 로고
    • A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy
    • Nilsson G. E., Tenland T., Öberg P. Å. A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy. IEEE Trans. Biomed. Eng. 27:1980b;12-19.
    • (1980) IEEE Trans. Biomed. Eng. , vol.27 , pp. 12-19
    • Nilsson, G.E.1    Tenland, T.2    Öberg P., Å.3
  • 11
    • 0032226003 scopus 로고    scopus 로고
    • Monte Carlo simulations of the light interaction with blood vessels in human skin in the red wavelength region
    • January 28-29, 53
    • Nilsson, H. Nilsson, G. E. 1998, Monte Carlo simulations of the light interaction with blood vessels in human skin in the red wavelength region, Proceedings of Optical Diagnostics of Biological Fluids III, January 28-29, 3252, 44, 53.
    • (1998) Proceedings of Optical Diagnostics of Biological Fluids III , vol.3252 , pp. 44
    • Nilsson, H.1    Nilsson, G.E.2
  • 12
    • 0027414712 scopus 로고
    • In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry
    • Obeid A. N. In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry. Med. Biol. Eng. Comput. 31:1993;43-52.
    • (1993) Med. Biol. Eng. Comput. , vol.31 , pp. 43-52
    • Obeid, A.N.1
  • 13
    • 0015428084 scopus 로고
    • Laser Doppler measurements of blood flow in capillary tubes and retinal arteries
    • Riva C., Ross B., Benedek G. B. Laser Doppler measurements of blood flow in capillary tubes and retinal arteries. Invest. Ophthalmol. 11:1972;936-944.
    • (1972) Invest. Ophthalmol. , vol.11 , pp. 936-944
    • Riva, C.1    Ross, B.2    Benedek, G.B.3
  • 17
    • 0000760095 scopus 로고    scopus 로고
    • Assessment of blood flow in separate vessels of the microcirculation using enhanced resolution laser Doppler perfusion imaging (ERLDPI)
    • Sjöberg F., Vayssettes-Courchay C., Vallez M. O., Nilsson G., Verbeuren T. J. Assessment of blood flow in separate vessels of the microcirculation using enhanced resolution laser Doppler perfusion imaging (ERLDPI). Int. J. Microcirc. Clin. Exp. 16:1996;106.
    • (1996) Int. J. Microcirc. Clin. Exp. , vol.16 , pp. 106
    • Sjöberg, F.1    Vayssettes-Courchay, C.2    Vallez, M.O.3    Nilsson, G.4    Verbeuren, T.J.5
  • 18
    • 85030344228 scopus 로고    scopus 로고
    • Assessment of cerebral cortex blood flow (CBF) by enhanced resolution laser Doppler perfusion imaging (ERLDPI)
    • Vayssettes-Courchay C., Sjöberg F., Nilsson G., Verbeuren T. J. Assessment of cerebral cortex blood flow (CBF) by enhanced resolution laser Doppler perfusion imaging (ERLDPI). Int. J. Microcirc. Clin. Exp. 16:1996;109.
    • (1996) Int. J. Microcirc. Clin. Exp. , vol.16 , pp. 109
    • Vayssettes-Courchay, C.1    Sjöberg, F.2    Nilsson, G.3    Verbeuren, T.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.