메뉴 건너뛰기




Volumn 36, Issue 6, 1998, Pages 761-767

A wideband high common mode rejection ratio amplifier and phaselocked loop demodulator for multifrequency impedance measurement

Author keywords

Electrical impedance; Equipment design; Instrumentation electronics; Isolated differential input; Transformer coupling

Indexed keywords

BIOELECTRIC PHENOMENA; DEMODULATORS; DIFFERENTIAL AMPLIFIERS; ELECTRIC IMPEDANCE TOMOGRAPHY; HIGH FREQUENCY TRANSFORMERS; PERFORMANCE;

EID: 0032211152     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02518881     Document Type: Article
Times cited : (12)

References (10)
  • 2
    • 0023341593 scopus 로고
    • An isolated microelectrode amplifier for measurements on papillary muscle subject to a rapid temperature step
    • GOOVAERTS, H. G. and METSELAAR. J. W. (1987): 'An isolated microelectrode amplifier for measurements on papillary muscle subject to a rapid temperature step,' Med. Biol. Eng. Comput., 25 pp. 324-328
    • (1987) Med. Biol. Eng. Comput. , vol.25 , pp. 324-328
    • Goovaerts, H.G.1    Metselaar, J.W.2
  • 4
    • 0032168878 scopus 로고    scopus 로고
    • An electrically isolated balanced wideband current source: Basic considerations and design
    • GOOVAERTS, H. G., FAES, Th. J. C., RAAIJMAKERS. E. and HEETHAAR, R. M. (1998): 'An electrically isolated balanced wideband current source: basic considerations and design,' Med. Biol. Eng. Comput., 36 pp. 598-603
    • (1998) Med. Biol. Eng. Comput. , vol.36 , pp. 598-603
    • Goovaerts, H.G.1    Faes, Th.J.C.2    Raaijmakers, E.3    Heethaar, R.M.4
  • 6
    • 0021353301 scopus 로고
    • A low noise isolated amplifier system for electrophysiological measurements: Basic considerations and design
    • HEUNINGEN, R. VAN, GOOVAERTS, H. G. and DE VRIES, F. R. (1984): 'A low noise isolated amplifier system for electrophysiological measurements: Basic considerations and design,' Med. Biol. Eng. Comput., 22 pp. 77-85
    • (1984) Med. Biol. Eng. Comput. , vol.22 , pp. 77-85
    • Heuningen, R.1    Van Goovaerts, H.G.2    De Vries, F.R.3
  • 7
    • 0026818684 scopus 로고
    • Design concepts of instruments for vector parameter identification
    • MIN, M., PARVE, T. and RONK, A. (1992): 'Design concepts of instruments for vector parameter identification,' IEEE Trans, Instr. Meas., 41, pp. 50-53
    • (1992) IEEE Trans, Instr. Meas. , vol.41 , pp. 50-53
    • Min, M.1    Parve, T.2    Ronk, A.3
  • 9
    • 0026761081 scopus 로고
    • Filtering respiration and low-frequency movements from the cardiogenic electrical impedance signal
    • RAZA, S. B., PATTERSON, R. P. and WANG, L. (1992): 'Filtering respiration and low-frequency movements from the cardiogenic electrical impedance signal.' Med. Biol. Eng. Comput., 30, 556-561
    • (1992) Med. Biol. Eng. Comput. , vol.30 , pp. 556-561
    • Raza, S.B.1    Patterson, R.P.2    Wang, L.3
  • 10
    • 0026493444 scopus 로고
    • An improved design of voltmeter for semi-parallel data acquisition
    • TRILLAUD. C. and JOSSINET, J. (1992): 'An improved design of voltmeter for semi-parallel data acquisition,' clin. Phys. Physiol. Meas., 13, (Supplement A), 5-10.
    • (1992) Clin. Phys. Physiol. Meas. , vol.13 , Issue.SUPPL. A , pp. 5-10
    • Trillaud, C.1    Jossinet, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.