메뉴 건너뛰기




Volumn 45, Issue 11, 1998, Pages 1110-1115

Methods for warming intravenous fluid in small volumes

Author keywords

[No Author keywords available]

Indexed keywords

ALBUMINOID; WATER;

EID: 0032200348     PISSN: 0832610X     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03012402     Document Type: Article
Times cited : (18)

References (17)
  • 1
    • 0002688672 scopus 로고
    • Thermal regulation - Physiology and perioperative management in infants and children
    • Motoyama EK, Davis PJ (Eds.). St-Louis: CV Mosby
    • Bissonnette B, Davis PJ. Thermal regulation - physiology and perioperative management in infants and children. In: Motoyama EK, Davis PJ (Eds.). Smith's Anesthesia for Infants and Children. St-Louis: CV Mosby, 1995: 139-58.
    • (1995) Smith's Anesthesia for Infants and Children , pp. 139-158
    • Bissonnette, B.1    Davis, P.J.2
  • 2
    • 0026094144 scopus 로고
    • Temperature relationship to distance and flow rate of warmed iv fluids
    • Faries G, Johnston C, Pruitt KM, Plouff RT. Temperature relationship to distance and flow rate of warmed iv fluids. Ann Emerg Med 1991; 20: 1198-200.
    • (1991) Ann Emerg Med , vol.20 , pp. 1198-1200
    • Faries, G.1    Johnston, C.2    Pruitt, K.M.3    Plouff, R.T.4
  • 3
    • 0009472110 scopus 로고    scopus 로고
    • Fluid temperature in IV tubing with and without blood warming. Are conventional fluid warmers effective in pediatric anesthesia?
    • Schultz J, Guest C, Bissonnette B. Fluid temperature in IV tubing with and without blood warming. Are conventional fluid warmers effective in pediatric anesthesia? Anesthesiology 1997; 87: A1045.
    • (1997) Anesthesiology , vol.87
    • Schultz, J.1    Guest, C.2    Bissonnette, B.3
  • 4
    • 0022569680 scopus 로고
    • Effects of environmental warming on blood components dispensed in syringes for neonatal transfusions
    • Strauss RG, Bell EF, Snyder EL, et al. Effects of environmental warming on blood components dispensed in syringes for neonatal transfusions. J Pediatr 1986; 109: 109-13.
    • (1986) J Pediatr , vol.109 , pp. 109-113
    • Strauss, R.G.1    Bell, E.F.2    Snyder, E.L.3
  • 5
    • 0022346848 scopus 로고
    • Techniques for warming red blood cells packaged in different containers for neonatal use
    • Luban NLC, Mikesell G, Sacher RA. Techniques for warming red blood cells packaged in different containers for neonatal use. Clin Pediatr 1985; 24: 642-4.
    • (1985) Clin Pediatr , vol.24 , pp. 642-644
    • Luban, N.L.C.1    Mikesell, G.2    Sacher, R.A.3
  • 7
    • 0026630481 scopus 로고
    • Evaluation of the Level 1 Hotline blood warmer
    • Smallman JMB, Morgan M. Evaluation of the Level 1 Hotline blood warmer. Anaesthesia 1992; 47: 869-71.
    • (1992) Anaesthesia , vol.47 , pp. 869-871
    • Smallman, J.M.B.1    Morgan, M.2
  • 9
    • 0018347294 scopus 로고
    • Warming of blood units in water bath and cooling of blood at room temperature
    • Linko K, Palosaari S. Warming of blood units in water bath and cooling of blood at room temperature. Acta Anaesthesiol Scand 1979; 23: 97-102.
    • (1979) Acta Anaesthesiol Scand , vol.23 , pp. 97-102
    • Linko, K.1    Palosaari, S.2
  • 10
    • 0016240876 scopus 로고
    • A review of blood warmers for massive transfusion
    • Russell WJ. A review of blood warmers for massive transfusion. Anaesth Intensive Care 1974; 2: 109-30.
    • (1974) Anaesth Intensive Care , vol.2 , pp. 109-130
    • Russell, W.J.1
  • 11
    • 0014496965 scopus 로고
    • A discussion of the problems of heat exchange blood warming devices
    • Russell WJ. A discussion of the problems of heat exchange blood warming devices. Br J Anaesth 1969; 41: 345-51.
    • (1969) Br J Anaesth , vol.41 , pp. 345-351
    • Russell, W.J.1
  • 12
    • 0347886895 scopus 로고    scopus 로고
    • Standards for blood banks and tranfusion services
    • American Association of Blood Banks. Standards for blood banks and tranfusion services. American Association of Blood Banks 1997; 1: 12.
    • (1997) American Association of Blood Banks , vol.1 , pp. 12
  • 13
    • 0016306928 scopus 로고
    • When does blood haemolyse? A temperature study
    • Chalmers C, Russell WJ. When does blood haemolyse? A temperature study. Br J Anaesth 1974; 46: 742-6.
    • (1974) Br J Anaesth , vol.46 , pp. 742-746
    • Chalmers, C.1    Russell, W.J.2
  • 14
    • 0347886897 scopus 로고
    • Anesthesia for premature infants
    • Gregory G. (Eds.). New York: Churchill Livingstone Inc
    • Gregory G. Anesthesia for premature infants. In: Gregory G. (Eds.). Pediatric Anesthesia, New York: Churchill Livingstone Inc, 1994: 351-73.
    • (1994) Pediatric Anesthesia , pp. 351-373
    • Gregory, G.1
  • 15
    • 0028335694 scopus 로고
    • Is blood warming before transfusion a safe procedure?
    • Rososhansky S, Szymanski I. Is blood warming before transfusion a safe procedure? (Letter) Anesth Analg 1994; 79: 197-8.
    • (1994) Anesth Analg , vol.79 , pp. 197-198
    • Rososhansky, S.1    Szymanski, I.2
  • 16
    • 0025158532 scopus 로고
    • Reports of 355 transfusion-associated deaths: 1976 through 1985
    • Sazama K. Reports of 355 transfusion-associated deaths: 1976 through 1985. Transfusion 1990; 30: 583-90.
    • (1990) Transfusion , vol.30 , pp. 583-590
    • Sazama, K.1
  • 17
    • 0025083667 scopus 로고
    • Hyperkalaemia during rapid blood transfusion and hypovolaemic cardiac arrest in children
    • Brown KA, Bissonnette B, McIntyre B. Hyperkalaemia during rapid blood transfusion and hypovolaemic cardiac arrest in children. Can J Anaesth 1990; 37: 747-54.
    • (1990) Can J Anaesth , vol.37 , pp. 747-754
    • Brown, K.A.1    Bissonnette, B.2    McIntyre, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.