메뉴 건너뛰기




Volumn 11, Issue 6, 1998, Pages 551-557

Laser-Welded Titanium Frameworks Supported by Implants in the Edentulous Maxilla: A 2-Year Prospective Multicenter Study

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY; GOLD ALLOY; PROCERA; RESIN; TITANIUM;

EID: 0032195975     PISSN: 08932174     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (19)

References (21)
  • 1
    • 0027018790 scopus 로고
    • Fixed implant-supported prosthescs with welded titanium frameworks
    • Jemt T, Linden B. Fixed implant-supported prosthescs with welded titanium frameworks. Int J Periodont Rest Dent 1992; 12:177-184.
    • (1992) Int J Periodont Rest Dent , vol.12 , pp. 177-184
    • Jemt, T.1    Linden, B.2
  • 2
    • 0029267167 scopus 로고
    • Laser-welded titanium frameworks for fixed prostheses supported by osseointegrated implants: A 2-year multicenter study report
    • Bergendal B, Palmqvist S. Laser-welded titanium frameworks for fixed prostheses supported by osseointegrated implants: A 2-year multicenter study report. Int J Oral Maxillofac Implants 1995;10:199-206.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 199-206
    • Bergendal, B.1    Palmqvist, S.2
  • 3
    • 0029351262 scopus 로고
    • Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations
    • Jemt T. Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations. J Oral Rehabil 1995;22:557-564.
    • (1995) J Oral Rehabil , vol.22 , pp. 557-564
    • Jemt, T.1
  • 4
    • 0029375103 scopus 로고
    • Stereo laser-welded titanium implant frameworks. Clinical and laboratory procedures with a summary of 1-year clinical trials
    • Rubenstein IE. Stereo laser-welded titanium implant frameworks. Clinical and laboratory procedures with a summary of 1-year clinical trials. J Prosthet Dent 1995;74:284-293.
    • (1995) J Prosthet Dent , vol.74 , pp. 284-293
    • Rubenstein, I.E.1
  • 5
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.-I.4
  • 6
    • 0030322726 scopus 로고    scopus 로고
    • A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants
    • Lindqvist LW, Carlsson GE, Jemt T. A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clin Oral Implants Res 1996;7:329-336.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 329-336
    • Lindqvist, L.W.1    Carlsson, G.E.2    Jemt, T.3
  • 7
  • 10
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt I. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-276.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 270-276
    • Jemt, I.1
  • 12
    • 0019234048 scopus 로고
    • Radiographic evaluation of osseointegrated implants of the jaws
    • Hollender L, Rockler B. Radiographic evaluation of osseointegrated implants of the jaws. Dent Maxillofac Radiol 1980;9: 91-95.
    • (1980) Dent Maxillofac Radiol , vol.9 , pp. 91-95
    • Hollender, L.1    Rockler, B.2
  • 15
    • 0029303074 scopus 로고
    • Implant treatment in edentulous maxillae: A 5-year follow-up report on patients with different degrees of jaw resorption
    • Jemt T, Lekholm U. Implant treatment in edentulous maxillae: A 5-year follow-up report on patients with different degrees of jaw resorption. Int J Oral Maxillofac Implants 1995;10:303-311.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 303-311
    • Jemt, T.1    Lekholm, U.2
  • 16
    • 0026810954 scopus 로고
    • A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism
    • Naert I, Quirynen M, van Steenberghe D, Darius P. A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992; 67:236-245.
    • (1992) J Prosthet Dent , vol.67 , pp. 236-245
    • Naert, I.1    Quirynen, M.2    Van Steenberghe, D.3    Darius, P.4
  • 17
    • 0027792944 scopus 로고
    • The association between the failure of dental implants and cigarette smoking
    • Bain CA, Moy PK. The association between the failure of dental implants and cigarette smoking. Int J Oral Maxillofac Implants 1993;8:609-615.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 609-615
    • Bain, C.A.1    Moy, P.K.2
  • 18
    • 0028685928 scopus 로고
    • The effect of smoking on early implant failure
    • De Bruyn H, Collaert B. The effect of smoking on early implant failure. Clin Oral Implants Res 1994;5:260-264.
    • (1994) Clin Oral Implants Res , vol.5 , pp. 260-264
    • De Bruyn, H.1    Collaert, B.2
  • 20
    • 0028249091 scopus 로고
    • Characteristics associated with the loss and peri-implant tissue health of endosseous dental implants
    • Weyant RJ. Characteristics associated with the loss and peri-implant tissue health of endosseous dental implants. Int J Oral Maxillofac Implants 1994;9:95-102.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 95-102
    • Weyant, R.J.1
  • 21
    • 0029377214 scopus 로고
    • Accuracy of implant-supported prostheses in the edentulous jaw. Analysis of precision of fit between gold-alloy frameworks and master casts by means of a 3-D photogrammetric technique
    • Jemt T, Lie A. Accuracy of implant-supported prostheses in the edentulous jaw. Analysis of precision of fit between gold-alloy frameworks and master casts by means of a 3-D photogrammetric technique. Clin Oral Implants Res 1995;6:172-180.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 172-180
    • Jemt, T.1    Lie, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.